PRECAUTIONS:

 during cleaning and normal maintenance operations, remember to disconnect the plug.

Under no circumstances should the appliance be washed with running water. Damage could be caused
to the electrical circuit.

AIR-FILTER CLEANING

— A clogged air filter reduces air circulation and the efficiency of the appliance. Clean the filter once a

week.

— To remove the filter, pull it up gently. Push down to replace.
— Use a vacuum cleaner to remove dust deposited on the filter. If it is very dirty, soak it in lukewarm water

and rinse thoroughly. The temperature of the water must be kept below 40

°

C. After washing, leave the

filter to dry before replacing.

CLEANING EXTERNAL HOUSING

Clean with a damp cloth and rub over with a clean dry cloth.

PRECAUTIONS: 

never use petrol, oil or similar solvents for cleaning. Never spray insecticides or similar

liquids. Serious damage may result to paintwork and plastic.

CLEANING COLLECTING TRAY

The collecting tray should be cleaned at least once a month to prevent dirt from accumulating after
prolonged use.

1) Switch off the appliance and disconnect the plug;
2) Open the water container compartment door and remove the container;
3) Remove the plug from the drainage tube situated at the back of the appliance and empty the water

into a bowl;

4) Once the container has been fully drained, replace the plug;
5) Remove any dirt from the surface below the container, rubbing with a cloth.

CONTROLS AT BEGINNING OF SEASON

Check that the power supply cable and the plug are in perfect condition.
Make sure that the system has been grounded and that the wire is not frayed and has not become
disconnected.

Please make sure to strictly follow the installation instructions.

END OF SEASON OPERATIONS

1) De-scale the unit. (see pg. 35)
2) Remove all traces of residual water using the drainage tube placed at the rear of the appliance (see

page 22)

3) Let the fan run for about half an hour to dry the inside of the air-conditioner
4) Switch off the unit and disconnect the plug from the power supply.
5) Remove the exhaust hose
6) Clean the filter and dry well before replacing
7) Cover the appliance with a polythene bag to prevent dust from entering.

Содержание PACCT 250

Страница 1: ...ime and effort to read this manual carefully Becoming familiar with the Pinguino is an essential step if you are to benefit fully from its exceptional qualities during both installation and actual use...

Страница 2: ...nditioning function TECHNICAL DATA Tab 1 IDEAL OPERATING CONDITIONS Tab 2 ROOM TEMPERATURE 21 32 C ROOM HUMIDITY FACTOR BELOW 80 WATER FUNCTION AIR FUNCTION Power supply voltage V 220 240 V Frequency...

Страница 3: ...llecting tray Water container compartment door Air filter Air intake grid Warranty envelope Exhaust hose compartment Handle Water collecting tray drainage tube Power cable compartment Castors Castor s...

Страница 4: ...PARTS SUPPLIED DESCRIPTION Exhaust hose Stopper flange Castor stop De scaling fluid Window nozzle Suction cup set 1 1 2 1 1 1...

Страница 5: ...rench window this temporary installation can be used at any time until it is ready for permanent installation Note In either case check that the unit is resting on at perfectly level surface If necess...

Страница 6: ...FOR HEATING FUNCTION Model CT250H The unit is simply placed in the room to be heated there is no need for the discharge hose to be installed ELECTRICAL CONNECTIONS The mains supply suitable for domes...

Страница 7: ...r container compartment door tip the container forwards and lift up to remove Afterfilling replacetheextendabletube screw the cap on tightly and return the container to its place making sure the word...

Страница 8: ...stallation in which case a window must be left partially open the room is well shaded from direct sunlight by drawing curtains and or partially lowering blinds or shutters to avoid excessive energy co...

Страница 9: ...switch in the TIMER ON position the TIMER ON OFF warning light on the control panel will light up 2 Set the operating times by pushing out the notches on the dial corresponding to the period required...

Страница 10: ...light will turn on Select the programmed or non programmed mode see previous page The button C must be released Turn the thermostat toward theMax Coldposition thick green line The appliance will turn...

Страница 11: ...indicates the correct time see instructions on setting 4 Select the desired function as shown in the chart overleaf The unit will now switch on and off each day at the selected times Note To override...

Страница 12: ...non programmed mode see previous page Select the fan speed required pressing Fan speed key C AIR CONDITIONING TurnthethermostattoMax Cold Press key A ON OFF The ON OFF signal lamp will come on The ap...

Страница 13: ...plug from the electrical outlet Do not use the power supply cable to pull the appliance when moving it Do not install the appliance in rooms where the air might contain traces of gas oil or sulphur o...

Страница 14: ...onth to prevent dirt from accumulating after prolonged use 1 Switch off the appliance and disconnect the plug 2 Open the water container compartment door and remove the container 3 Remove the plug fro...

Страница 15: ...nt sufficiently window open source of heat in room heater lamp etc room is overcrowded with people air exhaust hose has become disconnected thermostat regulated too high air filter blocked close windo...

Страница 16: ...t c Leave the air conditioner to operate for about half an hour d Drain away all the fluid left in the tray and rinse thoroughly The drainage tube should be open and the appliance switched on during d...

Отзывы: