DeLonghi PACAN125HPEK Скачать руководство пользователя страница 9

12

CLEANING

Before  cleaning  or  maintenance,  turn  the  appliance  off  by         
pressing  the  

  button, then unplug from electrical recep-

tacle.

CLEANING THE CABINET

You should clean the appliance with a slightly damp cloth then 
dry with a dry cloth.  For safety reasons, never wash the air con-
ditioner with water. 

Precautions

Never  use  petrol,  alcohol  or  solvents  to  clean  the  appliance. 
Never spray insecticide liquids or similar.

CLEANING THE BIO SILVER AIR FILTER

If the filter is dirty, air circulation is compromised and the ef-
ficiency  of  the  dehumidifying  and  air  purifying  functions  de-
creases. 
It is therefore good practice to clean the filter at regular inter-
vals. The frequency depends on the duration and conditions of 
operation. 
If the unit is used constantly or systematically, you are recom-
mended to clean the filter once a week.
The filter is housed in the intake grille.
To clean the filter, extract as shown in fig. 9.  

Use a vacuum cleaner to remove the dust collected on the filter. 
If it is very dirty, immerse in warm water and rinse a number 
of times. The water should never be hotter than 104°F (40°C).
After  washing  the  filter,  allow  it  to  dry  completely  before             
repositioning it.
The BioSilver filter helps capture dust and pollen and helps re-
duce the growth of bacteria and mold on the filter.

START OF SEASON CHECKS

Make sure the power cable and plug are undamaged and the 
ground connection is efficient.
Follow the installation instructions precisely.

END OF SEASON OPERATIONS

To drain all water from the circuit, remove the cap 

A10

 from the 

drainage on the back of the appliance and allow the water to 
drain out into a basin (fig. 10). 
To facilitate this operation, at the start of the season,  it’s possi-
ble to apply the water drain hose with cap  

B6

.

In order to properly storage the appliance at the end of the sea-
son, we suggest you cover it with the supplied end of season 
dust cover 

B8

 and you put the accessories in the relevant

end of season accessories bag 

B9

.

When the appliance is empty, replace the caps. 
Clean the filter and dry thoroughly before putting back.

TECHNICAL SPECIFICATIONS

Power supply voltage 

see rating label  

Max. absorbed power 
during air conditioning             “
Refrigerant                                      “
Cooling capacity 

          “

LIMIT CONDITIONS

Room temperature for air conditioning
(with fans at maximum speed)  

64 ÷ 104°F     18 ÷ 40°C

10

9

Содержание PACAN125HPEK

Страница 1: ...eaning or maintenance operations always unplug the unit from the outlet Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed where the atmos...

Страница 2: ...utlet If this is not the case you must choose another outlet Failure to follow these important safety instructions absolves the manufac turer of all liability If it becomes necessary the power cable m...

Страница 3: ...or log onto our website at www delonghi com SEMI PERMANENT INSTALLATION If required your appliance can also be installed semi perma nently Fig 6 min 11 8 in min 30cm min 11 8 in min 30cm Proceed as f...

Страница 4: ...onditioning dehumidifying fan heating C3 Decreasetemperature programmedoperationtimebutton C4 Timer button C5 Fan speed selection button LOW MED HIGH AUTO C6 Increase temperature programmed operation...

Страница 5: ...m speed for silent operation Medium speed reduces noise levels while main taining a comfortable temperature Maximumspeed toachievethetargettempera ture as rapidly as possible the appliance automatical...

Страница 6: ...ppliance into the electrical receptacle and turn the unit to standby Press the timer button C4 the timer symbol C13 and the number of hours come on Use the C6 or C3 buttons to set the number of hours...

Страница 7: ...e chapter OPERATING FROM THE CON TROL PANEL to select the desired functions Press button D5 to switch the temperature display from C to F and vice versa Note This equipment has been tested and found t...

Страница 8: ...ditioning Dehu midifying or Heating mode contact your localauthorizedservicecenter TIPS FOR CORRECT USE To ensure optimal results from your air conditioner follow these recommendations close the windo...

Страница 9: ...water should never be hotter than 104 F 40 C After washing the filter allow it to dry completely before repositioning it The BioSilver filter helps capture dust and pollen and helps re duce the growt...

Страница 10: ...ll not fit the outlet have a proper outlet installed by a qualified electrician or relocate the unit to a proper outlet If the household electrical supply does not meet the above specifica tions or if...

Страница 11: ...E given previously there are heat sources in the room oven hairdryer etc eliminate the heat sources the air exhaust hose is detached from the appliance fit the air exhaust hose in the housing at the b...

Страница 12: ...art We do not authorize any other person or company to assume for us any liability in connectionwiththesaleoruseofourAIRCONDITIONER ThiswarrantyshallnotapplytoanyAIRCONDITIONERthathasbeenrepaired or a...