DeLonghi PAC AN120EW Скачать руководство пользователя страница 10

13

TECHNICAL SPECIFICATIONS

Power supply voltage 

see rating label  

Max. absorbed power 
during air conditioning             “
Refrigerant                                      “
Cooling capacity 

          “

LIMIT CONDITIONS

Room temperature for 
air conditioning  

                           64 ÷ 104°F    18 ÷ 40°C

Transport, filling, cleaning, recovery and disposal of 

refrigerant should be performed by a technical service 

centre appointed by the manufacturer only.

The appliance should be disposed of by a specialist centre 

appointed by the manufacturer only.

TO AVOID DAMAGE TO THE UNIT: 

NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR 
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING 
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit 
has been on its side, oil needs to return to the compressor to en-
sure proper function.  Without allowing the unit this time (6-24 
hours) the unit may function for only a short time, and then the 
compressor will break down from lack of oil. 

ELECTRICAL CONNECTION

This appliance is equipped with a 3 prong grounded plug. The 
plug must be connected into an outlet that  is properly installed 
and grounded in the accordance with all local codes and ordi-
nances. Do not modify the plug provided with the appliance. 
If it will not fit the outlet, have a proper outlet installed by a 
qualified electrician or relocate the unit to a proper outlet. If the 
household electrical supply does not meet the above specifica-
tions, or if you are not sure your home has an effective  electrical 
ground, have a qualified electrician or your local electrical utility 
company check it and correct any problems.

SAFETY PLUG

The appliance is fitted with a safety plug to protect the power 
cable.
If power is cut off, unplug from the outlet and make sure the 
power cable is undamaged.
If the cable is damaged, call the service center immediately.
If power cuts off frequently and the power cable is undamaged, 
contact a qualified electrician.

OPERATION OF THE SAFETY PLUG

If the safety device incorporated in the plug trips and cuts off 
the power supply, check that the power cable and plug are not 
damaged.
If the power cable is undamaged, to restore operation press the 
"RESET" button. 
To verify correct operation of the plug, press the "TEST" button 
periodically and make sure the appliance disconnects. If this is 
not the case, contact the service center.
To restore operation, press the "RESET" button.

Содержание PAC AN120EW

Страница 1: ...the outlet Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed where the atmosphere may contain combustible gases oil or sulphur or near heat sources Donotresthotorheavyobjectsontheappliance Clean the filters at least once a week Avoid using heaters near the unit The unit should be transported in a vertical position If this is not possib...

Страница 2: ... you must choose another outlet Failure to follow these important safety instructions absolves the manufac turer of all liability If it becomes necessary the power cable must be re placed by a qualified professional only The instructions below will enable you to prepare your air con ditionerforoperationasefficientlyaspossible Beforeuse make sure the air intake and outlet grilles are unobstructed U...

Страница 3: ...emi perma nently Fig 5 min 12 inches min 30cm min 12 inches min 30cm Proceed as follows Drill a hole ø 5 25 inches 134 mm in an outside wall or through a window pane Respect the dimensions and height of the hole given in figure 6 and 7 134 Ø 5 25 inches Fit the wall flange B1 into the hole Fit the air exhaust hose B2 in the relevant housing located on the rear side of the appliance fig 1 Fittheend...

Страница 4: ...C5 Decreasetemperature programmedoperationtimebutton C6 Fan speed selection button LOW MED HIGH AUTO C7 WHISPER COOL selection button C8 REAL FEEL selection button C9 REAL FEEL light C10 Air conditioning symbol C11 Dehumidifying symbol C12 Fan symbol C13 Timer symbol C14 Alarm symbol C15 REAL FEEL symbol C16 WHISPER COOL symbol C17 Temperaturevalueset programmeddelayed ON OFFtime C18 Fan speed ind...

Страница 5: ...ithREAL FEEL onceoptimalcomfortisreached PACautomaticallymodu lates compressor action and fan speed to keep it over time To activate the function touch button Perfect Perfect REAL FEEL light C9 changes color when approaching the best comfort level see following diagram HIGH C F LOW LOW HIGH Perfect Perfect The well being feeling is a subjective condition for this reason different people may judge ...

Страница 6: ...ll main tains a good fan power Maximum speed for maximum fan power CHANGING TEMPERATURE SCALE x20 Thetemperaturecanbedisplayedin For C Tochangethetem peraturescale turnofftheunitbytouchingthe button then keep touched the MODE button for approximately 20 seconds The appliance emits a beep to confirm SETTING THE TIMER The timer can be used to delay appliance start up or shutdown This avoids wasting ...

Страница 7: ...ating in the same mode as when it was turned off To switch the appliance off press button D1 then remove the plug NOTE Never switch the appliance off by removing the plug Always switch it off by pushing on the button and waitingfewminutesbeforeremovingtheplug Onlyinthis way the appliance will perform the standard checkings FUNCTIONS SELECTION The controls on the remote control are the same as thos...

Страница 8: ...LAYED High Level Internaltrayfull WHAT SHOULD I DO Empty the internal safety tank following the instructions in the section End of season operations If HL alarm reoccurs frequentely contact your local authorized servicecenter SELF DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions Error messages are displayed on the appliance display TIPS FOR CORRECT USE To en...

Страница 9: ...ille To clean the filter extract as shown in fig 8 Use a vacuum cleaner to remove the dust collected on the filter If it is very dirty immerse in warm water and rinse a number of times The water should never be hotter than 104 F 40 C After washing the filter allow it to dry completely before repositioning it The BioSilver filter helps capture dust and pollen and helps re duce the growth of bacteri...

Страница 10: ...cordance with all local codes and ordi nances Do not modify the plug provided with the appliance If it will not fit the outlet have a proper outlet installed by a qualified electrician or relocate the unit to a proper outlet If the household electrical supply does not meet the above specifica tions or if you are not sure your home has an effective electrical ground haveaqualifiedelectrician oryour...

Страница 11: ... FOR CORRECT USE given previously there are heat sources in the room oven hairdryer etc eliminate the heat sources the air exhaust hose is detached from the appliance fit the air exhaust hose in the housing at the back of the appliance fig 1 dust filter clogged clean or replace the filter as described previously the technical specification of the appliance is not adequate for the room in which it ...

Страница 12: ...part We do not authorize any other person or company to assume for us any liability in connectionwiththesaleoruseofourAIRCONDITIONER ThiswarrantyshallnotapplytoanyAIRCONDITIONERthathasbeenrepaired or altered outside our factory nor shall it apply to any AIR CONDITIONER that has been subjected to misuse negligence or accidents If repairs become necessary see contact information below U S Residents ...

Отзывы: