19
INSTALLATION
MODELS WITHOUT SPECIAL COUPLINGS
The hose which connects the internal unit to the
external unit can be positioned in two ways:
In this case, it is necessary to disconnect the
internal unit as follows:
1) Remove the plug from the wall socket.
2) Remove the rear panel (on the back of the
appliance) by unscrewing the four retaining
screws.
3) Remove the metal brackets which fasten the
hose to the appliance (N. 3).
4) Using a 24mm spanner, unscrew the union on
the coupling. When doing this, use a 19mm.
spanner to block the extrimity of the hose in
position.
Repeat this operation for the second union.
The path of the connector hose should be as
straight as possible, without sharp curves or
kinks.
5) Detach the condensation hose from its
coupling.
6) Disconnect the electrical connector socket
by pressing the two retainer tabs.
a) Through a slightly-open window or door.
MODELS WITH SPECIAL COUPLINGS
If your air-conditioner is fitted with the special
rapid-fit coupling, the hose which connects the
internal unit to the external unit can also be
passed through a round hole in an external wall
(diameter: 6 cm. approx.).
Frame for hose
b) Through a small hole (5.5 x 2.5 cm.) in the
lower part of the door or window frame. In this
case, it is necessary to use the special frame
for the connection hose.