6
• Drill a hole ø 5,25 inches (134 mm) in an outside wall or
through a window pane. Respect the dimensions and
height of the hole given in figure 3 and 4.
134
Ø 5,25 in
3
• Fit the wall flange
B1
into the hole.
•
Fit the hose with the wall mounting accessory
B4
it into the
wall flange
B1
as shown in fig. 4.
• Fit the end of the hose
B2
to the wall flange
B1
as shown in
fig. 4.
• When the hose
B2
is not connected, the drilled hole can be
closed with the flange cap
B1
.
4
max 39 in
max 100 cm
min 14 in
min 35 cm
• When installing the air conditioner, you should leave a door
slightly open 1/2“ (1 cm) to guarantee correct ventilation
and room pressure.
• Keep the air hoses as short and free of curves as possible to
avoid constrictions.
NOTE:
•
As special tools are required for installation, we sug-
gest you have the appliance installed by a qualified
professional.
AIR CONDITIONING WITHOUT INSTALLATION
You can also set up in a double-hung window:
• Place the window bracket in the window sill, extend the
bracket fully within the window frame, fix the bracket by
using the pin then lower the window onto the bracket.
(Should the window bracket be too large for the window.
The plastic can be cut with a saw by a qualified profes-
sional.)
• Screw the hose adaptor
B3
to the hose’s end
B2
.
• Fit the air exhaust hose
B2
in the housing located on the
rear side of the appliance. (fig. 1).
• Screw the window outlet
B7
to the other end of the ex-
haust hose.
• Insert the window outlet
B7
of the exhaust hose into the
slot of the window bracket (fig. 5).
5
Other set-up methods:
• Thanks to the locking pins, it’s possible to use the window
bracket also for sliding windows. Position the hole of the
bracket so to allow a correct installation of the exhaust hose
(see figure 6).
in the wall:
you are
recommended to insulate
the section of wall using
suitable insulation
in the wooden
kickboard of a French
window or panel