background image

13

Содержание Electric Range DEGLSC 24 SS

Страница 1: ...inspector s use and for future reference Electrical installation must be in accordance with the National Electrical Code ANIS NFPA70 latest edition and or local codes IN CANADA Electrical installation must be in accordance with the current CSA C22 1 Canadian Electrical Codes Part 1 and or local codes This range is supplied with a protective film on steel and aluminium parts This film must be remov...

Страница 2: ... designed and manufactured solely for the cooking of domestic household food and in not suitable for any none domestic application and therefore should not be used in a commercial environmement The appliance guarantee will be void if the appliance is used within a none domestic environnement i e a semi commercial commercial or communal environment ...

Страница 3: ...injury or property damage Consult a qualified installer or a service agent IMPORTANT The use of suitable protective clothing gloves is recommended when handling installing of this appliance INSTALLATION INSTRUCTIONS TOOLS NEEDED FOR INSTALLATION NOT SUPPLIED WITH THE APPLIANCE Screwdriver Wrench Tape measure Pencil Adjustable pliers Adjustable wrench Suitable protective gloves Drill Hammer ...

Страница 4: ... safety considerations 2 AlI openings in the wall behind the appliance and in the floor under the appliance shall be sealed 3 Keep appliance area clear and free from combustible materials gasoline and other flammable vapors 4 Do not obstruct the flow of ventilation air 5 Disconnect the electrical supply to the appliance before servicing 6 When removing appliance for cleaning and or service A Disco...

Страница 5: ...mbustible surfaces TO THE LEFT above the 36 914 mm high countertop or there must be a minimum of 3 76 mm side clearance from the range to such combustible surfaces TO THE RIGHT above the 36 914 mm high countertop IMPORTANT One side left or right above the 36 914 mm high countertop must always be kept clear 3 The maximum upper cabinet depth recommended is 13 330 mm Wall cabinet above the range must...

Страница 6: ... 76 mm 13 max 330 mm 914 mm 36 0 0 mm 20 min 500 mm 30 min 457 mm 18 min 762 mm PROXIMITY TO SIDE CABINETS Fig 1 4 ASSEMBLING THE BACKGUARD It is mandatory to install the backguard Assemble the backguard as shown in figure 1 5 Screw the 2 screws A interposing the spacers Screw the central screw B Fig 1 3 Fig 1 5 ...

Страница 7: ... as shown on figure below only rear right side it has to be fixed on the floor and on the rear wall by no 4 four suitable screws not supplied 2 After fixing the anti tip bracket slide range into place Be sure the rear right foot slides under the anti tip bracket attached Supplied with the range in a separate kit Supplied with the range in a separate kit YOU MUST USE STABILITY ANTI TIP BRACKET TO P...

Страница 8: ...wo to three feet of slack in the line so that it can be moved if servicing is ever necessary ELECTRICAL CONNECTION WITH POWER CORD Use a 3 wire power supply cord kit rated for 55 amps 125 250 Volts with closed loop terminals and marked for use with ranges Where local codes do not permit grounding through neutral use a 4 wire power supply cord kit The cord or CSA UL listed conduit must be secured t...

Страница 9: ...ove the 3 wire terminal nuts and washers from the Terminal Block 4 Plug the terminal holes of Flat Power Cord The Neutral or Ground Wire of the Flat Power Cord must be connected to the neutral terminal located in the center of Terminal Block The Power Wires must be connected to the outside termi nals 5 Plug washers and tighten nuts securely Do not remove Ground strap 6 Assemble the Terminal Block ...

Страница 10: ...ain Relief group by unscrewing the Bracket Fixing Screws fig 2 3 3 Mount the Power Cord Bracket supplied with the range in a separate kit inside the Opening For Electrical Connection by screwing the 2 Fixing Screws as indicated in figure 2 4 4 Insert the Power Cord through the Power Cord Bracket then tighten the Power Cord by using the Power Cord Strain Relief Bracket Allow enough slack to easily ...

Страница 11: ...Block Access Plate Conduit Neutral Wire Power Wires Terminal Block Conduit Bracket Grounding Wire Cut Ground Strap Grounding Screw Conduit Clamp Fig 2 10 11 Conduit Neutral Wire Power Wires Terminal Block Ground strap Conduit Bracket Conduit Clamp Fig 2 9 3 Wire Conduit Installation See Figures 2 1 2 7 2 8 and 2 9 1 Remove the Terminal Block Access Plate on the back of the range by unscrewing the ...

Страница 12: ...P A B L1 EL 1000 SIEBE ST1 PROBE C ST2 ST4 ENCODER COOLING FAN ETA OVEN DOOR LATCH AUX ETA AUX ETA ST3 EL 1000 EL1000 LOCK UNLOCK RELAY 3 3 ETA ETA ETA 4 2 3 4 5 Safety Thermal overload GRILL ELEMENT BOTTOM ELEMENT INT 11 11a 12 12a TOP ELEMENT 13 13a 14 14a 15 15a 6 7 RELAY 2 EL 1000 RELAY 1 EL 1000 RELAY SWITCH E61 5a 5 16 16a 1 Safety Thermostat 33 ETA 34 ETA AIR SWITCH 3a 3 RELAY E61 2 2a 1 1a...

Страница 13: ...13 ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ...transcription errors in the present booklet The manufacturer reserves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and without prior notice without jeopardising the essential functional and safety characteristics of the appliances ...

Отзывы: