DeLonghi DEGCT424 Series Скачать руководство пользователя страница 10

10

installation to the cabinet

min

22” 7/16
(570 mm)

30” 

(762 mm)

18” 

(457 mm)

min 4”

(102 mm)

from cut-out

max 13”

(330 mm)

30” 

(762 mm)

min 20”

(508 mm)

from cut-out

max 13”

(330 mm)

18” 

(457 mm)

min

22” 7/16

(570 mm)

Fig. 4.2a

Fig. 4.2b

22” 53/64

(580 mm)

19” 11/16

(500 mm)

2” 9/16

(65 mm)

18” 7/8

(480 mm)

2” 9/16

(65 mm)

24”

(610 mm)

22” 1/64

(560 mm)

(CUT-OUT)

(CUT-OUT)

min 4"
(102 mm)
from cut-out

19” 11/16

(500 mm)

2” 5/32

(55 mm)

2” 5/32

(55 mm)

2” 9/16

(65 mm)

18” 7/8

(480 mm)

2” 9/16

(65 mm)

24”

(610 mm)

22” 1/64

(560 mm)

(CUT-OUT)

(CUT-OUT)

min 20"

(508 mm)

from cut-out

19” 11/16

(500 mm)

2” 5/32

(55 mm)

2” 5/32

(55 mm)

Fig. 4.1a

Fig. 4.1b

Fig. 4.1c

COOKTOP DIMENSIONS

BOX DIMENSIONS

Содержание DEGCT424 Series

Страница 1: ...ces Please ensure that this product is properly grounded The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference The electr...

Страница 2: ...this booklet carefully It may be useful in future either to yourself or to others in the event that doubts should arise relating to its operation This appliance must be used only for the task it has...

Страница 3: ...The appliance should be installed and all the gas electrical connections made by a qualified engineer in compliance with local regulations in force and following the manufacturer s instructions TIPS...

Страница 4: ...c gas lighting device is incorporated into the knobs The appliance has a safety valve system fitted the flow of gas will be stopped if and when the flame should accidentally go out CAUTION If the burn...

Страница 5: ...ng adjustments can be achieved by positioning the indicator between the maximum and minimum aperture positions and never between the maximum aperture and OFF positions N B When the cooktop is not bein...

Страница 6: ...r with a chamois leather For difficult dirt use a specific non abrasive product available commercially or a little hot vinegar Note regular use could cause discolouring around the burners because of t...

Страница 7: ...fig 3 1 next to each burner is always clean to ensure correct operation of the safety valves Both the probe and ignition plug must be very carefully cleaned Both the probe and ignition plug must be v...

Страница 8: ...alteration services or maintenance can cause injury or property damage Consult a qualified installer service agent or the gas supplier INSTALLATION INSTRUCTIONS TOOLS NEEDED FOR INSTALLATION Screwdri...

Страница 9: ...ance before servicing 9 When removing appliance for cleaning and or service A Shut off gas at main supply B Disconnect AC power supply C Disconnect gas line to the inlet pipe D Carefully lift applianc...

Страница 10: ...ig 4 2b 22 53 64 580 mm 19 11 16 500 mm 2 9 16 65 mm 18 7 8 480 mm 2 9 16 65 mm 24 610 mm 22 1 64 560 mm CUT OUT CUT OUT min 4 102 mm from cut out 19 11 16 500 mm 2 5 32 55 mm 2 5 32 55 mm 2 9 16 65 m...

Страница 11: ...front of the countertop and also between the back side of the cooktop and the back of the countertop Important Base cabinet construction must allow for size of cooktop cutout Gas line opening Wall an...

Страница 12: ...om as the cooktop and should be in a location that allows ease of opening and closing in a position where it can be reached quickly in the event of an emergency Do not block access to the shutoff valv...

Страница 13: ...not to damage the thread STEP 2 Mount the extension pipe to the elbow connection interposing the gasket supplied and tighten by using a wrench When tightening keep the elbow connection firm i e by usi...

Страница 14: ...cylindrical ISO 228 1 female 3 8 NPT conical male 3 8 NPT female 3 8 NPT female WARNING check the right positioning of the gas regulator The arrow on the back of the gas regulator must be oriented to...

Страница 15: ...mount a step down regulator will be required e The appliance its individual shut off valve and pressure regulator must be disconnected from the gas supply piping system during any pressure testing of...

Страница 16: ...the cooktop All strains must be removed from the supply and fuel lines so cooktop will be level and in line Use joint compounds and gaskets that are resistant to action of natural or propane gas on a...

Страница 17: ...sconnected and then connected again to the gas supply line repeat the operations indicated in paragraph 5 Leak Testing at page 16 OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS Remove the...

Страница 18: ...und method For your personal safety this cooktop must be grounded This cooktop is equipped with a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong g...

Страница 19: ...19 Wiring diagram key A Ignition coil PA Ignition switches group M Terminal block CA Igniter Fig 6 2 A N L PA M CA CA CA CA WIRING DIAGRAM...

Страница 20: ...anscription errors in the present booklet The manufacturer reserves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and without...