background image

H

ow to dehumidify

1) Plug the appliance into a mains socket. The power light comes on to show the appliance

is connected to the mains.

2) Check that the “tank full/no tank” indicator light is off.

3) Turn the humidistat to the “CONTINUOUS” position and the mode selector to the

“DEHUMIDIFICATION” position. The dehumidification pause light comes on during the first
three minutes (safety device), followed by the dehumidification light.

4) Select maximum or minimum fan speed (the relevant light comes on).

When the humidity in the room has reached the required level, slowly turn the humidistat knob
anticlockwise until the dehumidifying light goes out. The dehumidifier will then keep the
humidity in the room at the selected level automatically.

Note:  When dehumidifying, the appliance not only dehumidifies but also slightly warms the air 

(1-2°C hotter than room temperature)

H

ow to heat

1) Plug the appliance into a mains socket.
2) Turn the thermostat knob to position 5.
3) Turn the mode selector to the “HEATING” position. The heating light        comes on and the

appliance starts up. 

4) Select the economy (   /

1

= 800 W) or maximum (    /

2

= 1600 W) heating level  on the

speed/heat selection button (the corresponding light comes on).

When the temperature in the room has reached the required level, slowly turn the thermostat
knob anticlockwise until the heating light goes out. 
The thermostat will then keep the temperature in the room at the selected level automatically.

C

ombined mode, (dehumid heating)

1) Plug the appliance into a mains socket.
2) Check that the “tank full/no tank” warning light is off.
3) Turn the humidistat knob to the “CONTINUOUS” position.
4) Rotate the mode selector to the “COMBI” position. The (      )light comes on together with

the dehumidification pause light for the first three minutes (safety device), followed by the
dehumidification light.

5) Select maximum or minimum fan speed (and consequently the electrical power). In this

mode, the electrical power will be 1,990 W or 1.190 W.

6) When the humidity in the room has reached the required level, slowly turn back the

humidistat knob anticlockwise until the dehumidifying and heating lights go out. The
dehumidifier will then keep the humidity at the set level.

Note:  The appliance  only  stops completely when the level of humidity set is reached.  If the

tank is full, the tankfull warning light comes on and the refrigerant circuit stops however
the heater will continue to work. 

18

S e l e c t i n g   o p e ra t i n g   m o d e s

DE320GB  28-05-2001 16:59  Pagina 18

Содержание DE320

Страница 1: ... to preserve furniture and other objects varies between 45 and 60 Ideally rooms should therefore be kept within these values A dehumidifier is an appliance that eliminates the excess of moisture on the air see below There is another way to decrease the relative humidity level It is by increasing the room temperature Increasing the temperature is equivalent to increasing the capacity of the contain...

Страница 2: ...y suitable for drying clothes COMBI DRYER function To ensure optimum results and maximum safety read this instruction manual carefully before installing and using the appliance Advantages 13 Introduction ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ yyyyy yyyyy yyyyy yyyyy yyyyy ECON 800W MAX 1 600W ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ ÀÀÀÀÀ yyyyy yyyyy yyyyy yyyyy y...

Страница 3: ...5 6 7 1 Control panel cover 2 Control panel 3 Canister door 4 Condensate collection tank 5 Air intake grille 6 Air purifying filter 7 Lifting handle Accessory Description No provided rubber bung condensate drain hose 1 2 m 1 DE320GB 28 05 2001 16 59 Pagina 14 ...

Страница 4: ...e to the ozone layer if relased into the atmosphere Therefore at the end of the working life of the appliance the unit should be taken to a recycling centre for disposal of the refrigerant The materials used for packaging can be recycled You are therefore recommended to dispose of them in special differentiated waste collection containers The dehumidifier must be used only as indicated in this man...

Страница 5: ... but you are unable to empty the tank you are recommended to use the continuous drain facility 1 Remove the rubber bung from the spout Fig 2 2 Make a hole in the tank inside the spout using a fine drill bit 8mm Fig 2 3 To fit the rubber hose to the spout open the door remove the tank pass the drain hose provided through the space between the door at a slight angle and the bottom of the appliance r...

Страница 6: ...e light goes out and the appliance resumes operation Description of controls Heating indicator light Dehumidifying indicator light Dehumidifying mode OFF position appliance off Air circulation Heating mode Combined dehumidifying heating mode to heat and dehumidify simultaneously Thermostat knob Humidistat knob Power indicator light indicates that the appliance is connected to the mains Tank full n...

Страница 7: ...speed heat selection button the corresponding light comes on When the temperature in the room has reached the required level slowly turn the thermostat knob anticlockwise until the heating light goes out The thermostat will then keep the temperature in the room at the selected level automatically Combined mode dehumidifying heating 1 Plug the appliance into a mains socket 2 Check that the tank ful...

Страница 8: ...liance Never spray the appliance with insecticides or similar These could cause the paint to flake or plastic parts to warp Cleaning the air filter If the filter is dirty air circulation is compromised and the efficiency of the dehumidifying and air purifying functions decreases It is therefore good practice to clean the filter at regular intervals The frequency depends on the duration and conditi...

Страница 9: ...resistor protective device has cut in plug into the mains check the power supply set the humidistat to the required level empty the tank gently place the tank in the correct position clean the filter in certain conditions it is normal for the appliance not to dehumidify see Technical characteristics switch the appliance off wait 30 minutes then turn on again If the problem is no solved call the Te...

Страница 10: ...tion filter yes Dimensions LxHxD 365x610x375 mm Weight net 22 Kg Canister capacity 5 5 litres Operating limits Heating Dehumidifying temperature Max 27 C 5 32 relative humidity Max 95 30 95 Note The quantity of water dissolved in the air drops as the temperature is reduced For example at 5 C and with 80 relative humidity there are less than 5 grams of water vapour in every cubic metre of air In th...

Отзывы: