9
GAS SUPPLY:
■
The connection must be performed by an authorised person according to the rel-
evant standards.
■
Before connecting the appliance to the gas main, mount the brass conical adap-
tor onto the gas inlet pipe, upon which the gasket has been placed (figs. 6-7).
Conical adaptor and gasket are supplied with the appliance (packed with conver-
sion kit for use with Natural gas or ULPG).
■
This appliance is suitable for use with Natural Gas or ULPG. (Check the “gas type”
sticker attached to the appliance).
■
For Natural Gas models the gas supply is connected to the pressure regulator
which is supplied with the appliance (fig. 7). Adjust the regulator to obtain a test
point pressure of 1 kPa with the two semi-rapid (SR) burners operating at maxi-
mum.
■
For ULPG models the gas supply is connected to the test point adaptor which is
supplied with the appliance (fig. 6) and ensure that the supply pressure is regulat-
ed to 2.75 kPa.
■
The connection must be made at the rear of appliance (left or right); the pipe
does not cross the cooker.
■
The inlet not used must be closed off with the cap and sealing gasket supplied.
■
IMPORTANT: Use two spanners to tighten or loosen the connecting pipe (fig. 8).
Содержание DE 60 GW
Страница 44: ...cod 1103194 2...