background image

4

SAVE THESE 
INSTRUCTIONS

THIS PRODUCT IS FOR 
HOUSEHOLD ONLY

Appropriate use

The appliance is designed and produced for
domestic use only.
Use this appliance only as described in this
instruction manual. 
As with all electrical equipment, the instructions aim
to cover as many eventualities as possible.
However, caution and common sense should be
applied when operating and installing this applian-
ce.

General safeguards

Do not install the appliance in rooms contai-
ning gas, oil or sulphur. Do not install near
sources of heat.

Do not use the appliance on sloping surfaces.

Keep the appliance at least 2 ft (61cm) away
from flammable substances (alcohol etc) or
pressurised containers (e.g. aerosol cans).

Do not rest heavy or hot objects on top of the
appliance.

Always transport the appliance upright, NOT
on its side. 
Remember to drain the condensate tank befo-
re moving the appliance. 
If the appliance was transported on its side,
you must wait at least 6 hours before using it
(24 hrs is recommended).
ENVIRONMENTAL INFORMATION:  This unit
contains fluorinated greenhouse gases cove-
red by the Kyoto Protocol. Avoid perforating
the refrigerant circuit of the appliance.
Maintenance and disposal must be carried out
by qualified personnel only (R410A,
GWP=1975).

The materials used for packaging can be recy-
cled.
You are therefore recommended to dispose of
them in special differentiated waste collection
containers.

Do not use the appliance outdoors.

Do not use the appliance in laundry rooms.

Instructions

Read these instructions carefully before installing
and/or using the appliance.

Keep these instructions. 
If the appliance is transferred to other owners,
they should also be given these instructions.

Failure to respect the instructions may result
in injury or damage to the appliance.
The manufacturer is not liable for damage
deriving from failure to follow these instruc-
tions.

Electrical connections 

Before plugging the appliance into the outlet,
check that:

The outlet,  power supply corresponds to the
working voltage indicated on the rating plate.

The power outlet,  and electrical circuit are
adequate for the appliance.

The power outlet, matches the plug. If this is
not the case, have the plug replaced by a qua-
lified electrician;

The outlet is properly grounded.

INSTALLATION

Position the appliance in the room to be dehumi-
dified. A free space of at least 2 ft (61 cm) must
be left at the front of the dehumidifier, so as not to
block the air outlet.
For efficient ventilation a space of about  2-4 in (5-
10 cm) should be left at the back of the appliance. 
The condensate can be drained in one of the fol-
lowing ways:

A) Draining into the tank

The condensate can be drained directly into the
tank. The tank can be easily removed (fig.1).
When the tank is full, remove (fig.1) and empty it
into a sink. When finished, replace it properly.
NOTE:  The tank must be positioned porperly for
the unit to function.
If you hear the intermittent sound of the beep, it
means the tank is not in the proper position.

B) Continuous external draining 

If the appliance is to be operated for long periods
but you are unable to empty the tank regularly,
you are recommended to use continuous drai-
ning. 

Содержание DD45

Страница 1: ...and 60 relative humidity Lower relative humidity can be achieved with higher room temperatures For lower room temperatures the achievable relative humidity will be on the higher side closer to 60 Ther...

Страница 2: ...nabling you to unplug the appliance when necessary Always unplug the appliance using the plug itself Never pull the cable as it might be damaged To disconnect the appliance completely from the electri...

Страница 3: ...Instructions Read these instructions carefully before installing and or using the appliance Keep these instructions If the appliance is transferred to other owners they should also be given these inst...

Страница 4: ...ly on pump models The patented heavy duty pump system allows water removal of up to 13 ft 4m in height If you want the water to flow directly to a drain connect the condensation discharge tube supplie...

Страница 5: ...that the pump is not operating correctly 6 Timer button If you press the TIMER button the display will show the hours after which you want the applian ce to switch OFF or ON Once the timer is set the...

Страница 6: ...point the appliance will automatically resume dehumidification operation Continuous Dehumidifying Function In order to operate the continuous dehumidifying function press button untill the display wi...

Страница 7: ...nctions decreases It is therefore good practice to clean the filter at regular intervals The frequency depends on the duration and conditions of operation If the unit is used constantly or systematica...

Страница 8: ...nvironment Decrease the humidity set point The safety device has tripped Wait for 3 minutes to pass The tank is missing The tank is full The tank is incorrectly positioned The temperature in the room...

Страница 9: ...he owner of the unit This warranty shall apply only if the appliance is used in accordance with the factory directions that accompany it and on an Alternating Current AC cir cuit This warranty is in l...