background image

Converter Ethernet TCP/IP 10/100 Mbps RJ45 to Serial 

RS-232 DB9 with Client - Server - Mode

Product-No:64081

User manual no:64081-a

www.delock.com

User manual

Содержание 64081

Страница 1: ...Converter Ethernet TCP IP 10 100 Mbps RJ45 to Serial RS 232 DB9 with Client Server Mode Product No 64081 User manual no 64081 a www delock com User manual...

Страница 2: ...ss and query IP address through serial setting protocol Support DNS function Set parameters through webpag Auto MDI MDIX RJ45 port with 10 100Mbps Serial port baud rate from 1200 bps to 921 6 Kbps Che...

Страница 3: ...following requirements 1 Two personal computers PCS with a local area network LAN environment are required 2 A HyperTerminal program running on PC 1 is used as the control program to communicate with...

Страница 4: ...of HyperTerminal on PC1 will be transmitted to the HyperTerminal on PC2 and vice versa The following are the detailed device server setup procedures Step 1 Connect one end of RS 232 cable in PC2 s CO...

Страница 5: ...to Ethernet Converter firmware code will assign a default static IP address i e 192 168 0 3 Of course users can also change the static IP address via the AXR2E Configuration Utility or the Remote Conf...

Страница 6: ...R2E Configuration Utility running on PC1 is used to configure device servers 3 2 3 Server Mode Setup Device server 2 will set to Server mode by using the default setting 3 2 4 Client Mode Setup Becaus...

Страница 7: ...tion Utility 3 2 5 Testing Procedure Step 1 Power on device server 2 Server Step 2 Wait for several seconds till the AXR2E Configuration Utility Search function find the device server 2 successfully S...

Страница 8: ...Installation Step1 Run AX110xx RS232 to Ethernet Toolkit setup program and the installation wizard will appear on the screen Step 2 Wait for setup wizard to finish the software package installation th...

Страница 9: ...s of RS 232 to Ethernet Converter device servers 4 DHCP Server tool enable an RS 232 to Ethernet Converter device server to get a dynamic IP address when operating at the DHCP enabled mode 5 TFTP Serv...

Страница 10: ...m Log Window 1 Menu Window displays supported tools and existed VSP Ports list 2 Function Window displays supported functions of a selected tool 3 System Log Window mainly displays system log messages...

Страница 11: ...bar 5 View Status Bar Hides shows the status bar 6 Help Contents opens the help file 7 Help About displays the information of product version The Toolbar of AXR2E Configuration Utility supports the f...

Страница 12: ...and so on 3 5 Virtual Serial Port Operation Step 1 In Menu Window select Virtual Serial Port tool Step 2 Click the Add button to add a virtual serial port The COM Port Configuration dialog will appea...

Страница 13: ...g to configuration of the targeted device Here assumes the settings are as follows Parameter Setting Connection Protocol TCP Remote Host IP 10 1 2 22 Remote Host Port 5000 Enable Flow Control Packet D...

Страница 14: ...Step 6 Click the Connect button to make a TCP connection with the remote device server You will see the update of the virtual serial port s status in both the Function Window and the Menu Window...

Страница 15: ...you need to enable the administrator authority Below shows how 1 Select the AXR2E_x86 exe or AXR2E_x64 exe from Program File RS 232 to Ethernet Converter Configuration Utility folder 2 Right click on...

Страница 16: ...er s UART2 port is connected to the COM7 port on PC1 And this device server has established a TCP connection with the Virtual Serial Port COM1 on PC1 Step 1 In Menu Window select COM Port Terminal too...

Страница 17: ...ud rate 8 data bits no parity check 1 stop bit and no flow control Step 3 Input some text data e g 11111 in the console of COM Terminal 1 and then you should see the data appear in the console of COM...

Страница 18: ...ndow select Virtual Serial Port tool Select the virtual serial port COM1 from the Virtual Serial Ports List and then click the Close button to close the connection between the virtual serial port driv...

Страница 19: ...Restore Reboot period 2 Search searches available device servers on the LAN 3 IP Search searches the device server with specified IP address 4 Device Setup configures the settings of a selected devic...

Страница 20: ...server name 16 bytes maximum string MAC Address Device server MAC address DHCP Enable or disable IP If DHCP is enabled dynamic IP is acquired from the DHCP server Or static IP is assigned as dynamic I...

Страница 21: ...ovides two functions 1 OK enables the new period setting 2 Cancel cancels the new period setting The Setting dialog provides following parameters Parameter Description Search period 100ms Set the sear...

Страница 22: ...arching dialog provides two functions 1 Search starts the search operation 2 Cancel cancels the search operation The Devices Searching dialog provides following parameters Parameter Descriptio n Multi...

Страница 23: ...og provides two functions 1 Search starts the search operation 2 Cancel cancels the search operation The IP Search dialog provides following parameters Parameter Descriptio n IP The device server s IP...

Страница 24: ...ts of two tabs Network Setting and Serial Port Setting 1 Network Setting The Network Setting tab provides following parameters Parameter Description Device Name Device identification string MAC Addres...

Страница 25: ...Addresses Configuration Parameters Enable Enable disable accessible IP addresses IP 1 Accessible IP address 1 IP 2 Accessible IP address 2 IP 3 Accessible IP address 3 IP 4 Accessible IP address 4 SM...

Страница 26: ...its Parity Parity check Stop bits Stop bits Flow control Flow control RS 485 Mode RS 485 mode 3 7 1 6 Firmware Upgrade Dialog 1 Select the AX110xx RS 232 target board from the Devices List in the Func...

Страница 27: ...start upgrading the new AX110xx 5 RS 232 firmware code 3 7 2 Virtual Serial Port Tool This section describes the detailed functions of Virtual Serial Port tool 3 7 2 1 Main Window The main window of...

Страница 28: ...ort When a virtual serial port is added successfully it will be added in the Virtual Serial Ports List and the following information is displayed Category Descriptio n Port ID The identification value...

Страница 29: ...3 7 2 2 Add a Virtual Serial Port 1 Click the Add button to add a virtual serial port Below example shows a COM6 virtual serial port being added...

Страница 30: ...s Remote Host Port The target device server s port number Enable Flow Control Packet Enable disable the virtual serial port sending and receiving flow control packets This function is dependent with t...

Страница 31: ...application and then click the Close button to close the connection 3 7 2 6 Auto binding function The auto binding function enables you to connect a virtual serial port with a device server easier and...

Страница 32: ...via the Virtual COM Ports tree s context menu 4 To add a virtual serial port you can move the mouse cursor onto the Virtual COM Ports tree item and then right click the mouse button Then select the Cr...

Страница 33: ...n click the Web Browser button The tool will open a browser and connect automatically to the web server of the target device server the Login web page will appear Method 2 You can manually open a web...

Страница 34: ...ple you can enter asix com tw or 10 1 4 100 in this field This page supports four button commands 1 Apply submits this page s settings to the device server 2 Cancel cancels the changed settings on thi...

Страница 35: ...o continue the operation or click the Cancel button to cancel the operation 3 7 3 3 Advance Web Page In this page the E mail Server Address IP field can accept host name or IP address format for examp...

Страница 36: ...areful in using You need to make sure to enter correct accessible IP address s after enable this function the new configuration will take effect after the device server reboot When click the Apply but...

Страница 37: ...Before start the monitor function you need to select at least one device server from the Devices List in the Function Window of Device Management tool The main window supports one parameter that you...

Страница 38: ...device server UART2 s Modem Status register Firmware Version Production firmware version Serial Port TX Count Device server UART2 s TX count in unit of bytes Serial Port RX Count Device server UART2 s...

Страница 39: ...gure Parameter Description Start IP Address The first available IP address for clients End IP Address The end available IP address for clients Gateway Router The network gateway s IP address Subnet Ma...

Страница 40: ...ting The main window supports one parameter that you can configure Parameter Description File Path The file path for TFTP file read requests 3 7 7 COM Port Terminal Tool This section describes the det...

Страница 41: ...he selected COM port 2 Close closes the selected COM port 3 Clear clears the console data 4 Purge clears the data stored in COM port buffer Each terminal supports six general COM port parameters that...

Страница 42: ...d test data TX Interval ms The time interval to send out a test data TX Data Length The test data s length 3 8 TCP Test Tool 3 8 1 Setup Step 1 Double click TCP Test Tool_2 3 to install 2 If the follo...

Страница 43: ...4 Click compatibility check Windows 7 running program in compatible mode check running program as administrator click OK after setting and then reinstall the program 1 3 4...

Страница 44: ...creen which is broken down into 2 sections 1 The REMOTE COMMUNICATIONS section This section is the TCP SESSION INITIATOR sender tool It is used for sending data to any remote IP address and definable...

Страница 45: ...data sessions to a remote location and TCP port is easy 1 Enter the Remote IP or HOSTNAME and the desired destination TCP port Since this is where you want the data to be sent it assumes that there m...

Страница 46: ...val The application will send the data stream every x seconds until you stop the software or de select the Auto Send button Default is every 1 second 5 Data will be displayed in the Sent Data Log You...

Страница 47: ...riginator client select the required data format ASCII or HEX and add Line Feeds and or Carriage Returns as needed 3 To send data back to the TCP originator just hit the Send button If you want to sen...

Страница 48: ...dle When two LED lights of the product are out at the same time the yellow and green LED lights are turned on again and work normally it can be determined that the factory settings are successfully re...

Страница 49: ...ng in order to reduce waste The WEEE logo on the device and the package indicates that the device should not be disposed in the normal household garbage You are responsible for taking the disused elec...

Отзывы: