A few meter readings in a limited number of specific areas of
a large mass can not be projected to indicate an average
moisture content of an entire bale.The readings can be very
helpful in providing an indication of the overall moisture con-
dition inside the bale and to detect areas of excessive mois-
ture. 

Meter readings may be used as an arbitrary guideline in
determining whether or not to accept or reject the material.
Since checking the moisture condition of bales is performed
when buying and selling, the specific value of the meter read-
ings remains an element to be agreed upon between buyer
and seller. Such an agreement should consider not only a spe-
cific “range” of readings, but the number and location of
where they are taken.

The following ranges can be used as a guideline and may help
to interpret the readings:  

h

Readings of 5%–10%, with EMC to 60% RH are usually

considered “dry”. 

h

Readings from 11%–20% with EMC to 95% are usually

considered “acceptable” but should be taken with some
reservation. 

h

Readings of 20%-40% are considered “wet” and unac-

ceptable.

CARE OF YOUR METER

To keep your meter in good working order:

h

Store your meter in a clean, dry place. The protective

carrying case provided is an ideal storage place when
the meter is not in use.

h

Change the 9-Volt battery as needed. Continued use with a

low battery may cause the meter to go out of calibration. 

h

Change contact pins as needed. Keep pin retainers hand

tightened.

h

Clean the meter, contact pins, and probes with any

biodegradable cleaner. Use the cleaner sparingly and on
external parts only. Keep the cleaner out of the external con-
nector. 

DO NOT IMMERSE THE METER OR ANY ELEC-

TRODE IN WATER.

h

Remove the battery if the meter will not be used for one

month or longer.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание P-2000

Страница 1: ...P 2000 owner s manual W H E N A C C U R A C Y I S T H E P O I N T TM www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 2: ...oint 5 Information About Your Readings 5 To Check the Accumulated Readings 6 To Reset the Meter 6 Applications 7 Using the 0 100 Arbitrary Scale 7 Testing Baled Scrap Paper 8 Care of Your Meter 9 Service for Your Meter 10 Warranty www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 3: ... microcontroller circuit h Averages up to 100 accumulated readings h 4 3 18 moisture range on paper h 0 100 reference scale for relative moisture indications in hygroscopic materials h 5 40 moisture range on baled scrap paper h Includes 1 9 volt battery h Includes sturdy carrying case h One year warranty Read Key Calibration Check Key Set Point Key Scale Key 2 D E L M H O R S T P 2 0 0 0 www Globa...

Страница 4: ...ng calibration there is no need to disconnect the external electrode if attached If you check the calibration and the display does not read 11 1 it is likely an indication of a low battery If this occurs change the battery immediately Continued use with a low battery may cause the meter to go out of calibration If you have a fresh battery and the instru ment still does not indicate an acceptable c...

Страница 5: ...current set point is displayed and scroll to the set point value desired hTo scroll backward through the set point values press and release the set point key Within one second press and hold the scale key Continue to hold the scale key and the set point will decrease hWhen scrolling in either direction release the key to stop at your desired set point hA buzzer sounds if the meter reads a value hi...

Страница 6: ...ic material be sure to clear the meter before moving on to the next scale if you do not want to group all of the readings together TO CHECK THE ACCUMULATED READINGS This feature displays the total number of all accumulated read ings for the selected material the average of those readings and the highest stored reading hTo view the readings press and release the calibration check key First the mete...

Страница 7: ...ecked on the specific material and corrections determined by the user Meter readings indicate moisture content at room tempera ture of 70º F 90ºF Meter readings will be affected by lower or higher temperatures Lower temperatures cause readings to be lower higher temperatures cause readings to be higher than the actual MC The meter tends to read the highest moisture content that is in contact with ...

Страница 8: ... be taken on samples con sidered to be at safe levels or in satisfactory condition These readings are then used as the standard against which subsequent readings on the same material are evaluated The standard for any given material is related to safe stor ability or any other property which is important for further production processing Testing Baled Scrap Paper hSet the meter scale for 3 baled s...

Страница 9: ...terpret the readings hReadings of 5 10 with EMC to 60 RH are usually considered dry hReadings from 11 20 with EMC to 95 are usually considered acceptable but should be taken with some reservation hReadings of 20 40 are considered wet and unac ceptable CARE OF YOUR METER To keep your meter in good working order hStore your meter in a clean dry place The protective carrying case provided is an ideal...

Отзывы: