www.dellonda.co.uk 3

     

B) Connect the BLUE neutral wire to the  

     neutral terminal ‘N’.

     C) Check that there are no bare wires and        

     ensure that all wires are correctly connected. 

•  Ensure that the cable outer sheath extends 

inside the cable restraint and that the restraint 

is tight. 

• 

DO NOT 

connect either wire to the earth 

terminal. 

•  Dellonda recommend that repairs are carried 

out by a qualified electrician.

•  Modern vehicles contain extensive electronic 

systems. You are required to check with 

the vehicle manufacturer, for any specific 

instructions regarding the use of this type of 

equipment on each vehicle. No liability will 

be accepted for damage/injury, where this 

product is not used in accordance with all 

instructions. 

•  GENERAL SAFETY

•  Leave the unit to stand on a level surface 

for 6 hours after unpacking and before first 

switch-on.

•  Keep the unit horizontal while it is running.

•  Allow 10cm side and 20cm rear space for 

ventilation.

•  Keep the unit dry and away from any heat 

source.

•  SPECIFICATION

•  Model no.:...................................................

DL

14

•  Capacity........................................................50L

•  Temperature range.....................-20

O

C

 - +20

O

C

•  Power rating................................................60W

•  Dimensions (w x d x h)......723 x 360 x 458mm

•  Internal (w x d x h).............550 x 270 x 375mm

•  Refrigerant..........................................    R1234yf

•  OPERATION

•  Plug the unit in and hold the On/Off button 

down for 3 seconds. Repeat to turn unit off.

•  The internal temperatures will display and the 

compressor will start.

• 

NOTE

: Only one temperature will show if the 

zone divider has been removed.

•  Press the setting button to set up either 

MAX

 

(fast cooling) or 

ECO

 (energy saving) mode.

•  Press the +/- to adjust target temperature.

• 

NOTE

: The temperature of the left hand zone 

cannot be set lower than that of the right hand 

zone.

•  To turn off the left hand zone (designated 

by the square symbol) hold down the + and - 

buttons at the same time for three seconds.

•  To turn the left hand zone back on, repeat the 

procedure.

• 

NOTE

: Ensure left hand zone is on before the 

partition is removed in order to run in single 

zone mode. If the left hand zone is off and the 

partition removed, the compressor will not 

turn on.

•  To set battery protection mode, with the unit 

turned on, press and hold the Setting button 

for 3 seconds.

•  The default setting for battery protection is 

High (H). This value should be set when the 

unit is drawing power from the car battery.

•  When connected to a portable power supply 

or other back-up battery, set mode to Medium 

(M) or Low (L) by cycling through the Setting 

button options.

• 

NOTE

: If the battery power supply to the unit 

does not switch off when the vehicle’s ignition 

is off,

 set battery mode to ‘H’ otherwise you 

may drain the vehicle battery.

• 

MAINTENANCE

•  Remove the power plug from the unit when 

performing cleaning or maintenance.

• 

DO

 

NOT

 use abrasive or chemical cleaning 

materials on any surface of the unit.

•  Wipe interior and exterior surfaces with a 

damp cloth and dry thoroughly with a clean 

dry cloth.

•  For more soiled surfaces use a neutral 

detergent, wipe down with a clean damp cloth 

and dry thoroughly with a clean dry cloth.

•  To defrost the unit, power it off, raise the lid, 

empty the contents and allow it to defrost. 

Carefully use a defrosting shovel to remove 

thawed ice.