Upgrade firmware through BMC
This section describes the steps to take to upgrade the VEP4600’s firmware remotely from a Linux or Windows server.
Topics:
•
Check the existing firmware version
•
Configure BMC management address in BIOS
•
Configure BMC management address on BMC console
•
Run the Unified firmware updater tool from a Linux server
Check the existing firmware version
To check the current VEP4600 firmware versions when an Operating system is installed:
a. To find the CPLD and BIOS versions:
From the CPU mgmt console:
●
ESXi is installed: scroll up to last boot output to see BIOS and CPLD versions
●
DiagOS installed: log in and type
updatetool -D ALL -V
b. To find the BMC version:
From BMC mgmt console: type
ipmitool -I lanplus -H 127.0.0.1 -U admin -P admin mc info
~ # ipmitool -I lanplus -H 127.0.0.1 -U admin -P admin mc info
Device ID : 32
Device Revision : 1
Firmware Revision : 2.00
IPMI Version : 2.0
Manufacturer ID : 12290
Manufacturer Name : Unknown (0x3002)
Product ID : 1147 (0x047b)
Product Name : Unknown (0x47B)
Device Available : yes
Provides Device SDRs : no
Configure BMC management address in BIOS
To run the Unified firmware updater tool remotely, a BMC management address must be configured. This can be done through
booting into the BIOS or from the BMC console.
1. From the BMC console window, run the following commands to boot into the BIOS:
ipmitool -I lanplus -H 127.0.0.1 -U admin -P admin chassis bootparam set bootflag
force_bios
ipmitool -I lanplus -H 127.0.0.1 -U admin -P admin power reset
2. In the BIOS, tab to
Server Mgmt
menu, then move cursor down to
BMC network configuration
.
Select BMC network configuration
6
16
Upgrade firmware through BMC
Содержание VEP4600
Страница 1: ...Dell EMC VEP4600 Operating System Installation Guide Dell Solutions October 2021 Rev A07 ...
Страница 9: ...VEP4600 start up and serial console connection 9 ...
Страница 29: ...4 When finished select q to exit UFW Enter your choice q Upgrade rNDC and x722 firmware workaround 29 ...
Страница 39: ...Configure BIOS and install RHEL OS 39 ...
Страница 40: ...40 Configure BIOS and install RHEL OS ...
Страница 43: ...2 The installation process begins Configure BIOS and install RHEL OS 43 ...
Страница 49: ...4 Go to the Boot tab 5 Under Boot Option 1 press Enter and select USB Configure BIOS and install Ubuntu OS 49 ...