background image

Product Announcement: 

This product is certificated to meet RoHS 

Directive and Lead-Free produced definition. 

Using approved critical components only is 

recommended when the situation to replace 

defective parts. Vender assumes no liability 

express or implied, arising out of any unauthorized 

modification of design or replacing non-RoHS 

parts. Service providers assume all liability.    

Qualified Repairability:

Proper service and repair is important to the safe, 

reliable operation of all series products. The 

service providers recommended by vender should 

be aware of notices listed in this service manual in 

order to minimize the risk of personal injury when 

perform service procedures. Furthermore, the 

possible existed improper repairing method may 

damage equipment or products. It is recommended 

that service engineers should have repairing 

knowledge, experience, as well as appropriate 

product training per new model before performing 

the service procedures. 

NOTICE:

!

 To avoid electrical shocks, the products should be 

connected to an authorized power cord, and turn 

off the master power switch each time before 

removing the AC power cord. 

!

 To prevent the product away from water or 

expose in extremely high humility environment.  

!

 To ensure the continued reliability of this 

product, use only original manufacturer’s 

specified parts.

To ensure following safety repairing behavior, put 

the replaced part on the components side of 

PWBA, not solder side.

To ensure using a proper screwdriver, follow the 

torque and force listed in assembly and 

disassembly procedures to unscrew screws.

!

 Using Lead-Free solder to well mounted the 

parts.

!

 The fusion point of Lead-Free solder requested in 

the degree of 220°C.

  1. Important Safety Notice

Содержание U4320Q

Страница 1: ...ipment or products It is recommended that service engineers should have repairing knowledge experience as well as appropriate product training per new model before performing the service procedures NOTICE To avoid electrical shocks the products should be connected to an authorized power cord and turn off the master power switch each time before removing the AC power cord To prevent the product awa...

Страница 2: ...2 Exploded view diagram with list of items Mid frame key board Speaker Panel Inter face board Power board Min bracket Rear cover Stand Usb board ...

Страница 3: ...agram 2 n w o D 0 3 B S U 1 n w o D 0 3 B S U t u o o i d u A C e p y T n I 4 1 1 P D n I 0 2 1 I M D H AC In Power Board Panel Function Key Board TypeC Down USB3 0 Down3 DP 1 4 In HDMI 2 0 In Interface Board Speaker USB Board ...

Страница 4: ... screws for unlocking mechanisms No 1 4 screw size M6x12 Torque 9 0 5kgfxcm 2 3 4 1 1 2 3 4 Lift the rear cover up carefully Disconnect the USB LVDS cable and function key cable from the connectors of the interface board and then remove the rear cover Use a Philips head screwdriver to remove 1pcs screw for unlocking the USB board unit then release the USB board unit and put it aside No 1 screw siz...

Страница 5: ...ten 3pcs screws for locking the function key board with the front bezel No 1 3 Screw size M2x2 4 Torque 0 8 0 2kgfxcm Tear off acetate tape then disconnect the panel lamp cables from the connectors of the circuit board U se a Philips head screwdriver to remove 4pcs screws for locking the bracket chassis module with the panel No 1 4 Screw size M6x12 Torque 9 0 5kgfxcm Lift up the bracket chassis an...

Страница 6: ...er board and interface board 9pcs No 1 screw size M4x8 Torque 6 0 5kgfxcm No 2 9 screw size M3x7 5 Torque 6 0 5kgfxcm Remove the circuit boards from the disconnect all of the cables bracket chassis module carefully and then Turn over the bracket chassis module Remove the Mylar from the hooks of the bracket and then use a Philips head screwdriver to remove screws for unlocking AC power outlet two N...

Страница 7: ...ctor of the interface board then connect the power connective cable to the the interface board Turn over the interface board and locate it into the bracket Use a Philips head screwdriver to tighten 4pcs screws for locking the interface board No 6 9 screw size M3x7 5 Torque 6 0 5kgfxcm S3 7 9 2 1 Panel preparation Take out 1pcs panel module from the carton remove the protective film by tearing off ...

Страница 8: ...ilips head screwdriver to tighten 4pcs screws for locking the bracket chassis module with the panel No 1 4 Screw size M6x12 Torque 9 0 5kgfxcm 2 3 4 1 Take 1pcs small bracket to assemble with T Con board then use a Philips head screwdriver to tighten 2pcs screws for locking the small bracket with T Con board No 1 2 Screw size M3x0 5x4 Torque 3 5kgfxcm S8 Move the bracket chassis module close to th...

Страница 9: ...8 5 3 4 1 Take 1pcs USB board 1pcs conductive foam 1pcs LVDS cable and 1pcs rear cover Connect the LVDS cable to the connector of the USB board then paste 1pcs conductive foam on the back of the USB board and then locate the USB board into the correct position of the rear cover Use a Philips head screwdriver to tighten 1pcs screw for locking the USB unit with the rear cover No 1 screw size M3x6 To...

Страница 10: ...d base then lift up the monitor to checking the gap between the front bezel with panel module then provide power supply and a video signal to the monitor then turn on the monitor for functionality check S18 S19 Use a Philips head screwdriver to tighten four screws for locking mechanisms Stick 1pcs label on the specific positions as the picture below shown No 1 4 screw size M6x12 Torque 9 0 5kgfxcm...

Страница 11: ...he power LED remains white Also depending upon the selected input one of the dialogs shown below will continuously scroll through the screen Dell UltraSharp 43 Monitor The display will go into Standby Mode in 4 minutes No HDMI Cable www dell com support U4320Q U4320Q or Dell UltraSharp 43 Monitor The display will go into Standby Mode in 4 minutes No DP Cable www dell com support U4320Q U4320Q or D...

Страница 12: ...pect the screen for abnormalities 5 Press Button 1 on the front panel again The color of the screen changes to red 6 Inspect the display for any abnormalities 7 Repeat steps 5 and 6 to inspect the display in green blue black white and text screens The test is complete when the text screen appears To exit press Button 1 again If you do not detect any screen abnormalities upon using the built in dia...

Страница 13: ...High Data Speed 6 Use the or button to specify the preferred transfer priority 7 The setting will be effective after you turn on the PC PIP PBP Mode If your monitor does not display full screen or the resolution is not of the native resolution of the PIP PBP mode it could be due to the graphic card s behavior Please follow the steps below 1 Right Click in desktop and Select Display settings 2 Sele...

Страница 14: ... no brightness Increase brightness and contrast controls via OSD Perform monitor self test feature check Check for bent or broken pins in the video cable connector Run the built in diagnostics Ensure that the correct input source is selected in the Input Source menu No video at HDMI DisplayPort USB Type C port When connected to some dongle docking device at the port there is no video when unplugin...

Страница 15: ...n from a static image left on the monitor for a long period of time Faint shadow from the static image displayed appears on the screen Set the screen to turn off after a few minutes of screen idle time These can be adjusted in Windows Power Options or Mac Energy Saver setting Alternatively use a dynamically changing screensaver Product Specific Problems Problem What you experience Possible solutio...

Страница 16: ... C interface of device cannot support DP alternate mode Set Windows to Projection mode Ensure that the USB Type C cable is not damaged No charging when using USB Type C connection to computer laptop and so on No charging Verify if the device can support one of 5 V 9 V 15 V 20 V charging profiles Verify if the Notebook requires a 65 W power adaptor If the Notebook requires a 65 W power adaptor it m...

Отзывы: