Страница 1: ...Dell Neworking S6000 Open Networking ON Installation Guide January 2017 ...
Страница 2: ...e to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury or death Copyright 2017 Dell Inc or its subsidiaries All rights reserved Dell EMC and other trademarks are trademarks of Dell Inc or its subsidiaries Other trademarks may be trademarks of their respective owners 2017 01 Rev A03 ...
Страница 3: ... and airflow 12 Fan combinations 12 Power 12 Storing components 13 4 NEBS compliance 14 Important information 14 5 S6000 ON installation 15 Unpack the system 15 Unpacking Steps 15 Rack or cabinet hardware installation 16 Rack mount safety considerations 16 Dell ReadyRails installation 16 Two post flush mount configuration 17 Two post center mount configuration 18 Four post threaded configuration 1...
Страница 4: ...IE example 32 ONIE Service Discovery on the S6000 ON System 33 USB storage 34 9 Specifications 35 Chassis physical design 35 IEEE standards 36 Agency compliance 36 USA Federal Communications Commission FCC statement 36 European Union EMC Directive Conformance statement 36 Japan VCCI compliance for class A equipment 37 Korean certification of compliance 38 Safety standards and compliance agency cer...
Страница 5: ...ted visible and invisible laser radiation may be emitted from the aperture of the optical transceiver ports Avoid exposure to laser radiation Do not stare into open apertures Topics Information symbols Related documents Information symbols This book uses the following information symbols NOTE The Note icon signals important operational information CAUTION The Caution icon signals information about...
Страница 6: ...u can use to create a configuration of 96 ports of 10 GbE small form factor pluggable plus SFP using breakout cables and eight ports of 40 GbE quad small form factor pluggable plus QSFP The S6000 ON power supply unit PSU side contains the PSU and fan modules Figure 2 S6000 ON PSU side view 1 PSU 1 2 Fan Modules 1 through 3 3 PSU2 The S6000 ON input output I O side includes Thirty two fixed QSFP po...
Страница 7: ... universal serial bus USB A port One USB B console port One RS 232 serial console port One RJ 45 Ethernet management port On board central processing unit CPU system Two hot plug redundant power supplies Three removable fan modules Temperature monitoring Software readable thermal monitor Real time clock RTC support Current monitoring for power management Standard 1U chassis high Physical dimension...
Страница 8: ...e A System status You can view S6000 ON status information using the light emitting diodes LEDs LED display The S6000 ON includes LED displays on both the I O and PSU side of the chassis as shown For LED information see your third party operating software documentation Figure 4 PSU and fan tray LEDs 1 Fan Tray 1 through 3 LEDs 2 PSU 1 and 2 LEDs Figure 5 I O side view LEDs 8 The S6000 ON system ...
Страница 9: ...led including incompatible airflow direction Power Status LED Off no power Solid green normal operations Blinking yellow a power supply has failed Locator LED Off locator function is disabled Blinking blue locator function is enabled Prerequisite The following is a list of components required for a successful installation of the S6000 ON NOTE Detailed installation instructions for the S6000 ON are...
Страница 10: ...AC Normal Airflow thirty two 40 Gbps QSFP ports two AC power supplies and three fan subsystems airflow from the I O side to the PSU side S6000 ON AC Reverse Airflow thirty two 40 Gbps QSFP ports two AC power supplies and three fan subsystems airflow from the PSU side to the I O side Fan with airflow from the I O side to the PSU side Fan with airflow from the PSU side to the I O side AC Power suppl...
Страница 11: ...ity responsible for the location Ensure that the area where you install your S6000 ON system meets the following safety requirements Near an adequate power source Connect the system to the appropriate branch circuit protection as defined by your local electrical codes Environmental temperature between 32 to 113 F from 0 to 45 C Relative humidity that does not exceed 90 percent noncondensing In a d...
Страница 12: ...n a configuration must be in the same airflow direction Installation of the fans is done as part of the factory install based on SKU type For proper ventilation position the S6000 ON in an equipment rack or cabinet with a minimum of 5 inches 12 7 cm of clearance around the exhaust vents When you install two S6000 ON systems near each other position the two chassis at least 5 inches 12 7 cm apart t...
Страница 13: ...st or heel ground strap when handling the S6000 ON and its accessories After you remove the original packaging place the S6000 ON and its components on an anti static surface Follow these storage guidelines Storage temperature must remain constant ranging from 4 to 158 F from 20 C to 70 C Store on a dry surface or floor away from direct sunlight heat and air conditioning ducts Store in a dust free...
Страница 14: ...connect the system to an external special protection device SPD To be NEBs compliant Locate your system in a restricted access area were only trained personnel are allowed access Install and connect your system to the common bonding network CBN You can also install and connect your system to the central office Connect the battery returns of your system as DC I Ground your system using a copper gro...
Страница 15: ...ment QSFP optic installation System power up Unpack the system NOTE Before unpacking the system inspect the container and immediately report any evidence of damage When unpacking the S6000 ON switch make sure that the following items are included One S6000 ON switch One RJ 45 to DB 9 female cable Two sets of rail kits no tools required Two PSUs At least one country region specific AC power cord S6...
Страница 16: ... total component power ratings do not exceed the circuit capabilities Overloaded power sources and extension cords present fire and shock hazards Elevated ambient temperature If installed in a closed rack assembly the operating temperature of the rack environment may be greater than the room ambient temperature Use care not to exceed the 40 C maximum ambient temperature of the switch Reduced air f...
Страница 17: ... 3 Two post flush mount configuration CAUTION Your system is not NEBS Earthquake Z4 compliant if you use this installation method 1 Remove the tool less latch castings from the front side of each ReadyRails assembly item 1 Use a Torx driver to remove the two screws from each front flange ear on the switch side of the rail Remove each latch casting Retain the castings for future rack requirements I...
Страница 18: ... bracket to the post flange with two user supplied screws item 3 4 Repeat this procedure for the second rail Two post center mount configuration CAUTION Your system is not NEBS Earthquake Z4 compliant if you use this installation method 1 Slide the plunger bracket rearward until it clicks into place and secure the bracket to the front post flange with two user supplied screws item 1 18 S6000 ON in...
Страница 19: ...d rail Four post threaded configuration CAUTION To be NEBS Earthquake Z4 compliant you must remove the tool less latch castings described in Step 1 1 Remove the tool less latch castings from each end of the ReadyRails assemblies Use a Torx driver to remove the two screws from each latch casting Remove each casting item 1 Retain the castings for future rack requirements S6000 ON installation 19 ...
Страница 20: ...s The following is an example of a front rack configuration For the 1U two post flush or center configurations slide the system into the rails in the same manner as the four post configurations Installing a 1U Front Rack You must configure the rails that are attached to the system 1 Attach the switch rails inner chassis members to the S6000 ON system The following illustration item 3 shows the det...
Страница 21: ...d slide the switch in until it is flush with front of rack About three inches prior to full insertion the rail locking feature engages to keep the switch from inadvertently sliding out of the rack and falling Figure 11 Front Rack Installation NOTE Do not the use the mounted Ready Rails as a shelf or a workplace S6000 ON installation 21 ...
Страница 22: ...d strap when handling the S6000 ON and its components WARNING When working with optical fibers follow all warning labels and always wear eye protection Never look directly into the end of a terminated or unterminated fiber or connector as this may cause eye damage 1 Position the optic so it is in the correct position The optic has a key that prevents it from being inserted incorrectly 2 Insert the...
Страница 23: ... cable is included for powering up an AC power supply You must order all other power cables separately NOTE ESD damage can occur if components are mishandled Always wear an ESD preventive wrist or heel ground strap when handling the S6000 ON system and its components Power up sequence When the system powers up the fans immediately come on at high speed The fan speed slows as the system continues t...
Страница 24: ...age can occur if components are mishandled Always wear an ESD preventive wrist or heel ground strap when handling the S6000 ON and its components WARNING To prevent electrical shock ensure that the S6000 ON is grounded properly If you ground your equipment incorrectly excessive emissions may result To ensure that the power cables meet your local electrical requirements use a qualified electrician ...
Страница 25: ...t the AC input of the router AC power supply installation NOTE The PSU slides into the slot smoothly Do not force a PSU into a slot as this action may damage the PSU or the S6000 ON chassis NOTE Ensure that you correctly install the PSU When you install the PSU correctly the power connector is on the left side of the PSU and the status LED is at the bottom of the PSU NOTE If you use a single PSU i...
Страница 26: ...NOTE The PSU slides into the slot smoothly Do not force a PSU into a slot as this action may damage the PSU or the S6000 ON chassis NOTE If a PSU fails you must replace the entire unit There are no field serviceable components in the PSU To request a hardware replacement see Technical Support NOTE If you use a single PSU install a blank plate in the other PSU slot Dell EMC recommends using power s...
Страница 27: ...n To configure your system after you have securely installed and powered on the S6000 ON see your open network installation environment ONIE compatible third party operating system documentation at http onie org Power supplies 27 ...
Страница 28: ...d between fan replacements Check the environmental factors regularly An increase in temperature and or particulate matter in the air might affect performance for example new equipment installation CAUTION Check the fans at six month intervals and replace them as necessary Regularly monitor the speeds of the cooling fans to accurately determine replacement intervals Topics Components Fan module ins...
Страница 29: ...curately determine air filter replacement intervals regularly monitor the speeds of the cooling fans An increase in overall fan speed may indicate a clogged filter You must replace the fan air filters with new filters you cannot clean and reuse the old fan air filters Replacement filter media must meet the requirements found in GR 63 CORE Minimum dust arrestance of 65 per ASHRAE Standard 52 1 1992...
Страница 30: ...s procedure be sure that your PC has a 9 pin serial port and that you have a terminal emulation program already installed and running on the PC NOTE If your PC s serial port cannot accept a female DB 9 connector acquire a DB 9 male to male adaptor 1 Install the provided RJ 45 connector side of the provided copper cable into the S6000 ON console port 2 Install the DB 9 female side of the provided c...
Страница 31: ...ardware that you intend to use 3 Keep the default terminal settings on the S6000 ON console as follows 115200 baud rate No parity 8 data bits 1 stop bit No flow control USB B console port access The terminal settings are the same for the USB B port and the console port 115200 baud rate No parity 8 data bits 1 stop bit No flow control When you connect the USB B port it becomes the primary connectio...
Страница 32: ... flow control Before you install an OS system After powering on the S6000 ON system it goes through a power on self test POST POST runs every time the switch is initialized and checks hardware components to determine if the switch is fully operational before booting After POST the system uses the Grub bootloader To select which entry is highlighted use the up and down arrow keys Press Enter to sel...
Страница 33: ...ip address Command If none of the ONIE Service Discovery methods are successful you can disable is using the onie discovery stop command You can install an operating system manually from HTTP FTP or TFTP using the onie nos install URL command The ONIE Install environment uses DHCP to assign an IP address to the management interface eth0 If that fails it uses the default IP address 192 168 3 10 255...
Страница 34: ...09 cylinders Units cylinders of 2048 512 1048576 bytes Device Boot Start End Blocks Id System 3 Mount the device dev sdb to the mnt usb directory ONIE mount t vfat dev sdb mnt usb NOTE The following message displays if the mnt usb directory is missing mount mounting dev sdb on mnt usb failed No such file or directory NOTE The following message displays if the USB device is not seen mount mounting ...
Страница 35: ...ance Chassis physical design Table 2 Chassis physical design Parameter Specifications Height 1 71 inches 43 5 mm Width 17 08 inches 434 mm Depth 18 11 inches 460 mm Weight 16 12 lbs 7 32 kg Table 3 Environmental parameters Parameter Specifications Operating temperature 32 to 113 F 0 to 45 C Operating humidity 5 to 90 RH non condensing Storage temperature 40 to 158 F 40 to 70 C Storage humidity 5 t...
Страница 36: ...pment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures necessary to correct the interference at their own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits Dell Networking is not responsible for any radio or television interference caused by using other than reco...
Страница 37: ...hich case you may be required to take adequate measures European Community Contact Dell Networking EMEA Central Dahlienweg 19 66265 Heusweiler Germany http www force10networks com german Tel 49 172 6802630 Email EMEA Central Sales Japan VCCI compliance for class A equipment Figure 18 VCCI compliance label WARNING Use the AC power cords with Dell Networking equipment only Do not use Dell Networking...
Страница 38: ...ems FDA Regulation 21CFR 1040 10 and 1040 11 IEC 60950 1 2nd Ed including all National Deviations and Group Differences Electromagnetic compatibility EMC Emissions International CISPR 22 2006 Class A Australia New Zealand AS NZS CISPR 22 2009 Class A Canada ICES 003 Issue 4 Class A Europe EN55022 2006 CISPR 22 2006 Class A Japan VCCI V 3 2011 04 Class A USA FCC CFR47 Part 15 Subpart B Class A Immu...
Страница 39: ... the European Union This label is applied to various products to indicate that the product is not to be thrown away but rather reclaimed upon end of life per this Directive Figure 21 The European WEEE symbol In accordance with the European WEEE Directive electrical and electronic equipment EEE is to be collected separately and to be reused recycled or recovered at end of life Users of EEE with the...
Страница 40: ...to access iSupport services If you do not have a userid and password you can request these at the website To request a userid password and iSupport services follow these steps 1 On the Dell Networking Support page click the Account Request link 2 Fill out the User Account Request form and click Send You will receive your userid and password by email 3 To access iSupport services click the LOGIN li...
Страница 41: ...s for all components installed in the chassis use the show hardware command 2 Request an RMA number from TAC by opening a support case Open a support case by Using the Create Service Request form on the Support page Contacting Dell EMC directly by email or by phone Provide the following information when using email or phone Part number description and serial number of the component Your name organ...