"NOT_REACHABLE: Syslog server
10.11.226.121 (port: 9140) is not reachable" SNMPv2-SMI::enterprises.6027.3.6.1.1.2.0 =
INTEGER: 2
Following is the sample audit log message that other syslog servers that are reachable receive:
Oct 21 00:46:13: dv-fedgov-s4810-6: %EVL-6-NOT_REACHABLE:Syslog server 10.11.226.121 (port:
9140) is not reachable
Following example shows the SNMP trap that is sent when connectivity to the syslog server is resumed:
DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (10230) 0:01:42.30 SNMPv2-MIB::snmpTrapOID.
0 = OID: SNMPv2-
SMI::enterprises.6027.3.30.1.1.2 SNMPv2-SMI::enterprises.6027.3.30.1.1 = STRING:
"REACHABLE: Syslog server
10.11.226.121 (port: 9140) is reachable"SNMPv2-SMI::enterprises.6027.3.6.1.1.2.0 = INTEGER: 2
Following is the sample audit log message that other syslog servers that are reachable receive:
Oct 21 05:26:04: dv-fedgov-s4810-6: %EVL-6-REACHABLE:Syslog server 10.11.226.121 (port: 9140)
is reachable
Troubleshooting SNMP Operation
When you use SNMP to retrieve management data from an SNMP agent on a Dell Networking router, take into account the following
behavior.
•
When you query an IPv4 icmpMsgStatsInPkts object in the ICMP table by using the
snmpwalk
command, the output for echo replies
may be incorrectly displayed. To correctly display this information under ICMP statistics, use the
show ip traffic
command.
•
When you query an icmpStatsInErrors object in the icmpStats table by using the
snmpget
or
snmpwalk
command, the output for
IPv4 addresses may be incorrectly displayed. To correctly display this information under IP and ICMP statistics, use the
show ip
traffic
command.
•
When you query an IPv4 icmpMsgStatsInPkts object in the ICMP table by using the
snmpwalk
command, the echo response output
may not be displayed. To correctly display ICMP statistics, such as echo response, use the
show ip traffic
command.
Transceiver Monitoring
To retrieve and display the transceiver related parameters you can perform a snmpwalk transceiver table OID to retrieve transceiver details
as per the MIB. This enables transceiver monitoring and identification of potential issues related to the transceivers on a switch.
•
Ensure that SNMP is enabled on the device before running a query to retrieve the transceiver information.
•
Value 0.0 would be returned in case of Tx/Rx power not being supported on the optics.
•
Empty string would be displayed if optics are not inserted in a port.
Example of SNMP Output for Transceiver Monitoring
Dell $ snmpwalk -v1 -c public 10.16.150.210 1.3.6.1.4.1.6027.3.11.1.3.1.1 | grep 2106373
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.1.2106373 = STRING: "Stack-Unit-1 OptionalModule-3
Port-5"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.2.2106373 = STRING: "Fo 1/3/5"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.3.2106373 = STRING: "40GBASE-SR4"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.4.2106373 = STRING: "AVAGO"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.5.2106373 = STRING: "AFBR-79E4Z-D-FT1"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.6.2106373 = STRING: "750382760048"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.7.2106373 = STRING: "0.0"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.8.2106373 = STRING: "-2.273117"
Table 105. SNMP OIDs for Transceiver Monitoring
Field (OID)
Description
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.1
Device Name
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.2
Port
Simple Network Management Protocol (SNMP)
893
Содержание S4048T-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 11 2 1 ...
Страница 148: ...Figure 10 BFD Three Way Handshake State Changes 148 Bidirectional Forwarding Detection BFD ...
Страница 251: ...Dell Control Plane Policing CoPP 251 ...
Страница 363: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 363 ...
Страница 511: ...Figure 64 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 511 ...
Страница 512: ...Figure 65 Inspecting Configuration of LAG 10 on ALPHA 512 Link Aggregation Control Protocol LACP ...
Страница 515: ...Figure 67 Inspecting a LAG Port on BRAVO Using the show interface Command Link Aggregation Control Protocol LACP 515 ...
Страница 516: ...Figure 68 Inspecting LAG 10 Using the show interfaces port channel Command 516 Link Aggregation Control Protocol LACP ...
Страница 558: ...Figure 84 Configuring Interfaces for MSDP 558 Multicast Source Discovery Protocol MSDP ...
Страница 559: ...Figure 85 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 559 ...
Страница 560: ...Figure 86 Configuring PIM in Multiple Routing Domains 560 Multicast Source Discovery Protocol MSDP ...
Страница 564: ...Figure 88 MSDP Default Peer Scenario 2 564 Multicast Source Discovery Protocol MSDP ...
Страница 565: ...Figure 89 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 565 ...
Страница 729: ...protocol spanning tree pvst no disable vlan 300 bridge priority 4096 Per VLAN Spanning Tree Plus PVST 729 ...
Страница 841: ...Figure 115 Single and Double Tag TPID Match Service Provider Bridging 841 ...
Страница 842: ...Figure 116 Single and Double Tag First byte TPID Match 842 Service Provider Bridging ...