Debugging and Diagnostics
This chapter describes debugging and diagnostics for the device.
Offline Diagnostics
The offline diagnostics test suite is useful for isolating faults and debugging hardware.
The diagnostics tests are grouped into three levels:
•
Level 0
— Level 0 diagnostics check for the presence of various components and perform essential path verifications. In addition,
Level 0 diagnostics verify the identification registers of the components on the board.
•
Level 1
— A smaller set of diagnostic tests. Level 1 diagnostics perform status/self-test for all the components on the board and test
their registers for appropriate values. In addition, Level 1 diagnostics perform extensive tests on memory devices (for example, SDRAM,
flash, NVRAM, EEPROM) wherever possible.
•
Level 2
— The full set of diagnostic tests. Level 2 diagnostics are used primarily for on-board loopback tests and more extensive
component diagnostics. Various components on the board are put into Loopback mode and test packets are transmitted through those
components. Level 2 diagnostics also perform snake tests using virtual local area network (VLAN) configurations.
Important Points to Remember
•
You can only perform offline diagnostics on an offline standalone unit or offline member unit of a stack of three or more. You cannot
perform diagnostics on the management or standby unit in a stack of two or more; if you do, a message similar to this displays:
Running Diagnostics on master/standby unit is not allowed on stack
.
•
Diagnostics only test connectivity, not the entire data path.
•
Diagnostic results are stored on the flash of the unit on which you performed the diagnostics.
•
When offline diagnostics are complete, the unit or stack member reboots automatically.
Running Offline Diagnostics
To run offline diagnostics, use the following commands.
For more information, refer to the examples following the steps.
1
Place the unit in the offline state.
EXEC Privilege mode
offline stack-unit
stack-unit-number
You cannot enter this command on a MASTER or Standby stack unit.
NOTE:
The system reboots when the offline diagnostics complete. This is an automatic process. The following warning
message appears when you implement the
offline stack-unit
command:
Warning - Diagnostic
execution will cause stack-unit to reboot after completion of diags. Proceed with
Offline-Diags [confirm yes/no]:y
After the system goes offline, you must reload or run the
online stack-unit
stack-unit-number
command for the normal operation.
2
Confirm the offline status.
66
1108
Debugging and Diagnostics
Содержание S4048T-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 11 2 1 ...
Страница 148: ...Figure 10 BFD Three Way Handshake State Changes 148 Bidirectional Forwarding Detection BFD ...
Страница 251: ...Dell Control Plane Policing CoPP 251 ...
Страница 363: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 363 ...
Страница 511: ...Figure 64 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 511 ...
Страница 512: ...Figure 65 Inspecting Configuration of LAG 10 on ALPHA 512 Link Aggregation Control Protocol LACP ...
Страница 515: ...Figure 67 Inspecting a LAG Port on BRAVO Using the show interface Command Link Aggregation Control Protocol LACP 515 ...
Страница 516: ...Figure 68 Inspecting LAG 10 Using the show interfaces port channel Command 516 Link Aggregation Control Protocol LACP ...
Страница 558: ...Figure 84 Configuring Interfaces for MSDP 558 Multicast Source Discovery Protocol MSDP ...
Страница 559: ...Figure 85 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 559 ...
Страница 560: ...Figure 86 Configuring PIM in Multiple Routing Domains 560 Multicast Source Discovery Protocol MSDP ...
Страница 564: ...Figure 88 MSDP Default Peer Scenario 2 564 Multicast Source Discovery Protocol MSDP ...
Страница 565: ...Figure 89 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 565 ...
Страница 729: ...protocol spanning tree pvst no disable vlan 300 bridge priority 4096 Per VLAN Spanning Tree Plus PVST 729 ...
Страница 841: ...Figure 115 Single and Double Tag TPID Match Service Provider Bridging 841 ...
Страница 842: ...Figure 116 Single and Double Tag First byte TPID Match 842 Service Provider Bridging ...