Installing System Components
81
Figure 3-11.
Removing and Installing a Redundant Power Supply
Installing a Redundant Power Supply
1
Verify that both power supplies are of the same type and have the same
maximum output power.
NOTE:
The maximum output power (shown in watts) is listed on
the power supply label.
2
Slide the new power supply into the chassis until the power supply is
fully seated and the release latch snaps into place. See Figure 3-11.
NOTE:
If you unlatched the cable management arm in step 2 of the previous
procedure, relatch it. For information about the cable management arm,
see the system’s rack documentation.
3
Connect the power cable to the power supply and plug the cable into a
power outlet.
CAUTION:
When connecting the power cable, secure the cable with
the Velcro strap.
1
power supply
2
power supply handle
3
velcro strap
4
release latch
1
3
2
4