• One RAID controller module in a redundant configuration has failed
• A battery has failed or has been removed
• A physical disk in a redundant virtual disk has failed
Invalid Storage Array
The RAID controller module is supported only in a Dell-supported storage array. After installation in the
storage array, the controller performs a set of validation checks. The array status LED is lit with a steady
amber color while the RAID controller module completes these initial tests and the controllers are
booted successfully. If the RAID controller module detects a non-Dell supported storage array, the
controller does not startup. The RAID controller module does not generate any events to alert you in the
event of an invalid array, but the array status LED is lit with a flashing amber color to indicate a fault state.
ECC Errors
RAID controller firmware can detect ECC errors and can recover from a single-bit ECC error whether the
RAID controller module is in a redundant or nonredundant configuration. A storage array with redundant
controllers can recover from multi-bit ECC errors as well because the peer RAID controller module can
take over, if necessary.
The RAID controller module fails over if it experiences up to 10 single-bit errors, or up to three multi-bit
errors.
PCI Errors
The storage array firmware can detect and only recover from PCI errors when the RAID controller
modules are configured for redundancy. If a virtual disk uses cache mirroring, it fails over to its peer RAID
controller module, which initiates a flush of the dirty cache.
49