Post Installation Tasks
Before using the Dell PowerVault storage array for the first time, complete these initial configuration tasks
in the order shown. These tasks are performed using the MD Storage Manager.
1.
For out-of-band management, you must set the network configuration for each RAID controller
module, including its Internet Protocol (IP) address, subnetwork mask (subnet mask), and gateway.
NOTE: You can set the network configuration using a DHCP server.
2.
Launch
MD Storage Manager
.
– Click
Start
→
Programs
→
Dell
→
MD Storage Manager
→
Modular Disk Storage Manager Client
on Microsoft Windows operating systems.
– Click the
PowerVault MD Storage Manager
desktop icon on Linux operating systems.
– You can also launch
PowerVault MD Storage Manager
in Linux by running the following
commands at the command prompt:
cd /opt/dell/mdstoragesoftware/mdstoragemanager/client./SMclient
3.
Go to
Setup
→
Add Storage Array
and start the automatic discovery of systems in the
Enterprise
Management Window
(EMW).
NOTE: Only storage arrays configured with IP address on the same subnet as the management
stations will be detected.
NOTE: It may take several minutes for the discovery process to complete. Closing the
Automatic Discovery Status
window before this stops the discovery process.
After discovery is complete, a confirmation screen is displayed.
4.
Click
Close
.
Verifying Storage Array Discovery
The
Automatic Discovery
option automatically discovers both in-band and out-of-band arrays and adds
the storage arrays to the management domain. If the out-of-band or in-band connections shown on the
summary page are not accurate, complete the following steps. For more information, see the Online
Help.
1.
Check the hardware and connections for possible problems.
For specific procedures on troubleshooting interface problems, see the
Dell PowerVault MD Series
Storage Arrays Owner's Manual
at
dell.com/powervaultmanuals
.
2.
Verify that the array is on the local subnetwork. If it is not, using MD Storage Manager, manually add
the storage array to the subnet.
3.
Verify that the status of each storage array is
Optimal
.
23
Содержание PowerVault MD3460 Series
Страница 1: ...Dell PowerVault MD3460 Series Storage Arrays Deployment Guide ...
Страница 8: ...8 ...
Страница 11: ...Figure 1 Two Hosts Connected to Two Controllers 11 ...
Страница 12: ...Figure 2 Four Hosts Connected to Two Controllers 12 ...
Страница 15: ...Figure 5 Four Cluster Nodes Connected to Two Controllers 15 ...
Страница 18: ...18 ...