4-16
Installation and Troubleshooting Guide
#
The
errShow
command displays all detected errors, one error at a time. The error log
stores the last 32 error types sensed by the switch. The log shows:
Error number (01-64)
Date and time of the first occurrence each error type was sensed
Total number of occurrences of each error type
NOTE: The maximum number of occurrences is 999.
Error type
—
Error level for each error type
—
0
= Panic (when this level is reached, the switch automatically reboots and
the display no longer shows the error)
—
1
= Critical
—
2
= Error
—
3
= Warning
—
4
= Debug
For a detailed explanation of each error type, its probable cause, and suggested cor-
rective actions, see Appendix A, “Error Messages.”
The following information is displayed in the
errShow
screen:
The switch detected two errors.
The task ID and task name that incurred the error (task names are displayed
using the
i
command). For example,
+!
.
The error type, date and time, the error level, and description.
—
If there is more than one occurrence of an error type, the number of occur-
rences is shown in brackets following the error date and time.
The following is an example of the
errShow
command screen.
Содержание PowerVault 50F
Страница 1: ... ...
Страница 12: ...xiv ...
Страница 16: ...xviii ...
Страница 30: ...1 6 Installation and Troubleshooting Guide ...
Страница 108: ...5 10 Installation and Troubleshooting Guide ...
Страница 116: ...6 8 Installation and Troubleshooting Guide ...
Страница 136: ...7 20 Installation and Troubleshooting Guide ...
Страница 160: ...A 24 Installation and Troubleshooting Guide ...
Страница 172: ...8 Installation and Troubleshooting Guide ...