![Dell PowerEdge R805 System Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/dell/poweredge-r805-system/poweredge-r805-system_hardware-owners-manual_85484030.webp)
30
About Your System
E1811
HDD ## Rbld
Abrt
The specified hard drive has
experienced a rebuild abort.
See "Troubleshooting a
Hard Drive" on page 155.
If the problem persists,
see your RAID
documentation.
E1812
HDD ##
Removed
The specified hard drive has
been removed from the
system.
Information only.
E1914
DRAC5 Conn2
Cbl
DRAC 5 cable is missing or
disconnected.
Reconnect the cable. See
"Installing a RAC Card"
on page 106.
E1915
IO55 HTSink
Missing
MCP55 Htsink
Missing
Heatsink sensor reports that
the chipset IO55 heatsink is
missing.
Heatsink sensor reports that
the chipset MCP heatsink
heatsink is missing.
See "Getting Help" on
page 175.
E1A12
PCI Rsr
Missing
One or all of the PCIe risers
is missing, preventing the
system from powering on.
Reinstall the missing riser
card(s).
E1A14
SAS Cable A
SAS cable A is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable. See "SAS
Controller Daughter
Card" on page 84.
E1A15
SAS Cable B
SAS cable B is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable. See "SAS
Controller Daughter
Card" on page 84.
E1A1C
LOM Mezz
Missing
LOM daughter card is
missing.
Install or reseat the LOM
daughter card. If the
problem persists, replace
the card. See "Getting
Help" on page 175.
Table 1-6.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions