Using the System Setup Program
43
Serial Communication Screen
Table 2-6 lists the options and descriptions for the information fields that appear on the
Serial
Communication
screen.
IDE CD-ROM Controller
(
Auto
default)
Enables the integrated IDE controller. When set to
Auto
, each channel of the
integrated IDE controller is enabled if IDE devices are attached to the channel and
the external IDE controller is not detected.
NOTE:
This option will not appear on this menu screen if your system does not include
this optional device.
Diskette Controller
(
Auto
default)
Enables or disables the system's diskette drive controller. When
Auto
is selected,
the system turns off the controller when necessary to accommodate a controller
card installed in an expansion slot. You can also configure the drive as
Read-Only
,
or
Off
. When using the
Read-Only
setting, the drive cannot be used to write to a
disk.
NOTE:
This option will not appear on this menu screen if your system does not include
this optional device.
User Accessible USB Ports
(
All Ports On
default)
Enables or disables the system’s user accessible USB ports. Options are
All Ports
On
,
Only Back Ports On
, and
All Ports Off
.
Embedded Gb NIC1
(
Enabled with PXE
default
)
Enables or disables the system's integrated NIC. Options are
Enabled without
PXE
,
Enabled with PXE
, and
Disabled
. PXE support allows the system to boot
from the network. Changes take effect after the system reboots.
MAC Address
Displays the MAC address for the integrated 10/100/1000 NIC. This field does not
have user-selectable settings.
TOE Capability
Displays the TCP/IP offload engine (TOE) feature status of the onboard NIC.
Embedded Gb NIC2
(
Enabled without PXE
default)
Enables or disables the system's integrated NIC. Options are
Enabled without
PXE
,
Enabled with PXE
, and
Disabled
. PXE support allows the system to boot
from the network. Changes take effect after the system reboots.
MAC Address
Displays the MAC address for the integrated 10/100/1000 NIC. This field does not
have user-selectable settings.
TOE Capability
Displays the TCP/IP offload engine (TOE) feature status of the onboard NIC.
Table 2-6.
Serial Communication Screen Options
Option
Description
Serial Communication
(
Off
default)
Options are
On without Console Redirection
,
On with Console
Redirection
via COM1
,
On with Console Redirection
via
COM
2, and
Off
.
Table 2-5.
Integrated Devices Screen Options
(continued)
Option
Description
Содержание PowerEdge 2970
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge 2970 Systems Hardware Owner s Manual ...
Страница 10: ...10 Contents ...
Страница 50: ...50 Using the System Setup Program ...
Страница 114: ...114 Installing System Components ...
Страница 138: ...138 Running the System Diagnostics ...
Страница 174: ...174 Getting Help ...
Страница 182: ...182 Glossary ...
Страница 188: ...88 Index 188 Index ...