| Installation Guide

3

Power Switch: The power switch has two states: Off (

) and On (|).

Power Management

The W-6000 supports up to three 400 W power supplies. If using one to two primary power supplies for 400 to 
800 W of primary power, the use of a 400 W redundant power supply is possible.

For maximum capacity planning, add the maximum power draw required for all of the modules in your chassis 
configuration to determine the required number of power supplies. 

M3 Module and PSU Configuration Table

The following table displays the M3 module configurations, and the resultant power supply configurations and 
power usage.

Table 2  

Power Supply and W-6000M3 Configurations

Inserting a Power Supply

1. Verify you understand the procedure and all precautions.

Before beginning, read the entire procedure. Verify you understand all the precautions in these steps as well as 
those on page 10.

2. Select a power supply slot for the power supply.

The 400 W power supply (HW-PSU-400) can be installed in any power supply slot and any power supply 
slot can be left empty. That is, there is no specific required order of slots used for power supplies.

Figure 2  

400 W Power Supplies Installed

If replacing a previously installed power supply, first see 

“Removing a Power Supply” on page

 

5

.

If you are installing a power supply in an empty slot, you may have to remove the blank cover plate first. To do 
this, use a #2 Phillips or cross-head screwdriver. Turn the captive fastening screws on the faceplate counter-
clockwise until they are loose (they cannot be completely removed). Remove the cover plate and store it in a safe 
place.

Module

Number of Units

M3 Controller Module

(130 W max power draw each)

1

2

3

4

Total Power (W)

130

260

390

520

Required number of PSUs

1

1

1

2

Redundant number of PSUs

1 or 2 1 or 2 1 or 2 1

7

CAUTION:  Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple 
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. 
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions 
that came with the product.

Содержание PowerConnect W-6000

Страница 1: ...urned on Load sharing divides the total power load of the W 6000 among all plugged in power supply modules Since the power supplies work together the effective power capacity of the chassis is increased with each additional power supply Redundancy When multiple power supplies are installed if one becomes unavailable fails or is turned off or removed the remaining power supplies will attempt to pro...

Страница 2: ...ket accepts power cords with standard IEC320 connectors For proper safety and performance the cord must be rated to 10 A and conform to grounded electrical standards in the country where the product is used O T P DC OK AC OK 1 7 6 5 4 1 2 3 6 5A MAX 1 2 CAUTION Do not use the power supply handle to lift or move the W 6000 Serious damage could result Table 1 400W Power Supply LEDs LED Name Position...

Страница 3: ...led in any power supply slot and any power supply slot can be left empty That is there is no specific required order of slots used for power supplies Figure 2 400 W Power Supplies Installed If replacing a previously installed power supply first see Removing a Power Supply on page 5 If you are installing a power supply in an empty slot you may have to remove the blank cover plate first To do this u...

Страница 4: ...wer supply Plug an appropriate power cord into the power input socket The socket accepts a power cord with a standard IEC320 plug 7 Secure the power cord When the power cord is attached swing the power cord retaining clip to the right as shown in Figure 3 on page 4 This will hold the plug in place and help prevent it from being removed accidentally Figure 3 Using the Power Cord Retaining Clip 8 At...

Страница 5: ...ull the module out of the chassis 5 Cover blank slots For safety considerations as well as to promote proper air flow for cooling and to prevent dust from entering the chassis cover any unoccupied slot with a blank cover plate CAUTION For safety reasons verify the power outlets and plugs are within easy reach of the operator and can be quickly disconnected if necessary NOTE Use of a power line con...

Страница 6: ...GPL or other Open Source Licenses The Open Source code used can be found at this site http www arubanetworks com open_source Legal Notice The use of Aruba Networks Inc switching platforms and software by all individuals or corporations to terminate other vendors VPN client devices constitutes complete acceptance of liability by that individual or corporation for this action and indemnifies in full...

Отзывы: