Beep Codes and Error Messages
3-7
Keyboard data
line failure
Keyboard
stuck key
failure
System cannot commu-
nicate with keyboard.
Keyboard cable connec-
tor loose or improperly
connected, defective
keyboard, or defective
keyboard/mouse control-
ler (defective system
board).
Memory
address line
failure at
address, read
value expect-
ing
value
Memory data
line failure
at
address,
read
value
expecting
value
Memory double
word logic
failure at
address, read
value expect-
ing
value
Memory odd/
even logic
failure at
address, read
value expect-
ing
value
Memory write/
read failure
at
address,
read
value
expecting
value
During memory test,
value read at
address
was incorrect.
Faulty or improperly
seated DIMMs or defec-
tive system board.
Memory alloca-
tion error
Software in use con-
flicts with operating
system, application pro-
gram, or utility.
Faulty application pro-
gram or utility.
Memory tests
terminated by
keystroke
Memory test did not
complete.
POST memory test termi-
nated by pressing
<Spacebar>.
Table 3-2. System Error Messages (continued)
Message
Definition
Probable Causes
Содержание OptiPlex GXi
Страница 1: ... HOO 2SWL3OH L 6 VWHPV 6 59 0 18 ...
Страница 2: ......
Страница 3: ... HOO 2SWL3OH L 6 VWHPV 6 59 0 18 ...
Страница 16: ...xvi DELL CONFIDENTIAL Preliminary 6 16 97 ...
Страница 18: ...xviii DELL CONFIDENTIAL Preliminary 6 16 97 ...
Страница 64: ...3 10 Dell OptiPlex GXi Systems Service Manual ...
Страница 142: ...A 6 Dell OptiPlex GXi Systems Service Manual ...
Страница 146: ......
Страница 147: ... www dell com Printed in the U S A P N 50560 Rev A01 ...