Parameters
vlan
vlan-range
Enter the keyword
vlan
then the VLAN numbers. The range
is from 1 to 4094.
forward-delay
seconds
Enter the keywords
forward-delay
then the time interval,
in seconds, that Dell Networking OS waits before
transitioning PVST+ to the forwarding state. The range is
from 4 to 30 seconds. The default is
15 seconds
.
Defaults
15 seconds
Command
Modes
CONFIGURATION (conf-pvst)
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version 9.0.2.0
Introduced on the S6000.
Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
Version 7.6.1.0
Introduced on the S-Series.
Version 7.5.1.0
Introduced on the C-Series.
Version 6.2.1.1
Introduced.
Related
Commands
— sets the bridge-priority value.
— changes the time interval between BPDUs.
— changes the time interval before PVST+ refreshes.
— displays the PVST+ configuration.
vlan hello-time
Set the time interval between generation of PVST+ 7 BPDUs.
S6000
Syntax
vlan
vlan-range
hello-time
seconds
To return to the default value, use the
no vlan hello-time
command.
Per-VLAN Spanning Tree Plus (PVST+)
1103
Содержание Networking S6000 System
Страница 1: ...Dell Command Line Reference Guide for the S6000 System 9 5 0 0 ...
Страница 558: ...Version 8 3 10 0 Introduced on the S4810 558 Equal Cost Multi Path ECMP ...
Страница 579: ...Version 8 3 12 0 Introduced on the S4810 FCoE Transit 579 ...
Страница 773: ...dropped in keepalive Dell Related Commands show ip cam stack unit displays the CAM table IPv4 Routing 773 ...
Страница 1319: ...Gi1 2 2 STP PVST Dell Related Commands show running config displays the current configuration Service Provider Bridging 1319 ...
Страница 1331: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell sFlow 1331 ...
Страница 1480: ...Version 8 3 8 0 Introduced on the S4810 1480 Virtual Link Trunking VLT ...