Power off a PowerStore T model node using PowerStore Manager
on page 112
●
Power off a PowerStore T model node using a service script
on page 112
●
Power off a PowerStore X model node
on page 113
Power off a PowerStore T model node using PowerStore Manager
Prerequisites
Obtain the following information:
●
Management IP address of the cluster to log in to PowerStore Manager
●
PowerStore Manager user account credentials with administrator privileges
NOTE:
Do not power off or reboot a node if the peer node is not operating normally. If the peer node is experiencing any
major issues, associated alerts and events appear in PowerStore Manager.
Also, to avoid service interruptions, ensure that there are sufficient and healthy paths from all connected hosts to the peer
node.
About this task
Use the following procedure to power off (power down) a PowerStore T model node using PowerStore Manager:
NOTE:
If you are unable to access PowerStore Manager, see
Power off a PowerStore T model node using a service script
on page 112.
Steps
1. Under
Hardware
, select the appliance that includes the node you want to power off.
2. On the
Appliance Details
page, select the
Components
card.
3. On the
Components
card, under
Rear View
, expand
Base Enclosure
, and then select the node that you want to power
off.
4. Under
More Actions
, select
Power Down
.
5. On the confirmation prompt, enter the service password, and then click
Power Down
.
Next steps
To verify that the node has powered off, check the status of the LEDs in the rear of chassis. Other than the LEDs for the power
supply unit, management port, and service port, all LEDs on the node must be OFF. The Unsafe to Remove LED on the active or
peer node is ON.
Power off a PowerStore T model node using a service script
Prerequisites
Obtain the following information:
●
Management IP address of the appliance that contains the node. In PowerStore Manager, go to
Settings
>
Networking
>
Networking IPs
>
Management
. Review the
Management IPs
table to identify the management IP address associated
with the appliance.
●
Service account credentials
NOTE:
Do not power off or reboot a node, if the peer node is not operating normally. If the peer node is experiencing any
major issues, associated alerts and events appear in PowerStore Manager.
Also, to avoid service interruptions, ensure that there are sufficient and healthy paths from all connected hosts to the peer
node.
About this task
Use the following procedure to power off (power down) a PowerStore T model node using a service script:
Steps
1. Launch an SSH client, and connect to the appliance using the management IP address.
112
Power control procedures