NOTE: If there is a persistence policy in effect and the virtual addresses, initiator, or storage targets are set on a CNA-
device partition, do not reset or clear the values configured for virtual addresses, initiator, and storage targets before
changing the VirtualizationMode or the personality of the partition. The action is performed automatically when you
disable the persistence policy. You can also use a configuration job to explicitly set the virtual address attributes to 0s
and the initiator and storage targets values as defined in
iSCSI initiator and storage target default values
Related links
Enabling or disabling I/O Identity Optimization
Configuring persistence policy settings using iDRAC web interface
To configure the persistence policy:
1.
In the iDRAC Web interface, go to
Overview
→
Hardware
→
Network Devices
.
The
Network Devices
page is displayed.
2.
Click
I/O Identity Optimization
tab.
3.
In the
Persistence Policy
section, select one or more of the following for each persistence policy:
•
A/C Power Loss
- The virtual address or target settings persist when AC power loss conditions occur.
•
Cold Boot
- The virtual address or target settings persist when cold reset conditions occur.
•
Warm Boot
- The virtual address or target settings persist when warm reset condition occurs.
4.
Click
Apply
.
The persistence policies are configured.
Configuring persistence policy settings using RACADM
To set persistence policy, use the following racadm object with the
set
sub command:
•
For virtual addresses, use
iDRAC.IOIDOpt.VirtualAddressPersistencePolicyAuxPwrd
and
iDRAC.IOIDOpt.VirtualAddressPersistencePolicyNonAuxPwrd
objects
•
For initiator, use
iDRAC.IOIDOPT.InitiatorPersistencePolicy
object
•
For storage targets, use
iDRAC.IOIDOpt.StorageTargetPersistencePolicy
object
For more information, see the
iDRAC RACADM Command Line Interface Reference Guide
available at
dell.com/esmmanuals
.
iSCSI initiator and storage target default values
The following tables provide the list of default values for iSCSI initiator and storage targets when the persistence policies are
cleared.
Table 32. iSCSI initiator —default values
iSCSI Initiator
Default Values in IPv4 mode
Default Values in IPv6 mode
IscsiInitiatorIpAddr
0.0.0.0
::
IscsiInitiatorIpv4Addr
0.0.0.0
0.0.0.0
IscsiInitiatorIpv6Addr
::
::
IscsiInitiatorSubnet
0.0.0.0
0.0.0.0
IscsiInitiatorSubnetPrefix
0
0
IscsiInitiatorGateway
0.0.0.0
::
IscsiInitiatorIpv4Gateway
0.0.0.0
0.0.0.0
IscsiInitiatorIpv6Gateway
::
::
180
Содержание iDRAC 7
Страница 1: ...iDRAC 8 7 v2 40 40 40 User s Guide ...
Страница 108: ...For more information see the iDRAC RACADM Command Line Interface Reference Guide available at dell com idracmanuals 108 ...
Страница 268: ...By default the logs are available at Event viewer Applications and Services Logs System 268 ...