Dell Force10 S2410 Скачать руководство пользователя страница 1

Installing the S2410 System

Содержание Force10 S2410

Страница 1: ...Installing the S2410 System ...

Страница 2: ...om and AMD Sempron are trademarks of Advanced Micro Devices Inc Microsoft Windows Windows Server MS DOS and Windows Vista are either trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries Red Hat Enterprise Linux and Enterprise Linux are registered trademarks of Red Hat Inc in the United States and or other countries Novell is a registered trademar...

Страница 3: ... 12 Storing Components 12 Tools Required 13 4 Installing the S2410 Tabletop Installation 15 Rack or Cabinet Installation 15 Attaching the Rack Ears 15 Two Post Rack Mounting 16 Four Post Rack mounting with Threaded Rails 17 Four Post Rack mounting with Cage Nuts 19 Supplying Power 21 Where Do I Go from Here 21 5 Accessing Ports Accessing the Console Port 23 Accessing the Ethernet Management Port 2...

Страница 4: ...y Compliance 28 Safety Standards and Compliance Agency Certifications 29 Electromagnetic Compatibility EMC 30 Product Recycling and Disposal 30 7 Technical Support The iSupport Website 33 Accessing iSupport Services 33 Contacting the Technical Assistance Center 34 Locating Serial Numbers 34 Requesting a Hardware Replacement 35 8 Index ...

Страница 5: ...erts and heed their warnings and cautions Table 1 1 describes symbols contained in this guide WARNING The installation of this equipment shall be performed by trained and qualified personnel only Read this guide before installing and powering up this equipment This equipment contains two power cords Disconnect both power cords before servicing WARNING This equipment contains optical transceivers w...

Страница 6: ...he S2410 Documentation CD ROM and on the iSupport website registration for access to some sections is required http www force10networks com csportal20 KnowledgeBase Documentation aspx The iSupport website also has a section for S Series techtips and FAQs See The iSupport Website on page 33 The CD ROM also has MIBs Files for all SNMP MIBs supported by SFTOS Data sheets Force10 product data sheets S...

Страница 7: ...ired Equipment The following items are necessary to install the S2410 system Two grounded AC power sources 10 100EthernetManagementPort StatusLEDs Console Port 20 XFP Ports S2410P 20 CX4 Ports S2410CP or 4 XFP Ports Label AssemblyandSerial 070 00285 00 1 10 100EthernetManagementPort StatusLEDs Console Port 20 XFP Ports S2410P 20 CX4 Ports S2410CP or 4 XFP Ports Label AssemblyandSerial 070 00285 00...

Страница 8: ...en built in fans on the left side see Fans and Airflow on page 12 Load sharing redundant internal AC power supplies Up to 16000 MAC address entries supported with hardware assisted aging Supports 9000 jumbo frames Back pressure support at half duplex IEEE 802 3x flow control at full duplex Extensive LEDs for per port and system statuses see LED Displays on page 9 Ports S2410CP 20 fixed 10GbE BaseC...

Страница 9: ... blinking rate is 1 Hz Unit is operational Error during boot Alarm Off Amber Red No alarm Minor alarm Fan or temperature is outside acceptable range Major alarm PSU A and PSU B Off Green Red PSU not present PSU present and OK Red could mean that the PSU is present but failed or that one power cord that used to be connected is now disconnected The syslog message indicates AC Power removed or fault ...

Страница 10: ...10 The S2410 System w w w d e l l c o m s u p p o r t d e l l c o m ...

Страница 11: ...ate power source Connect the system to the appropriate branch circuit protection as defined by your local electrical codes Ideally you connect each power supply to a separate circuit Environmental temperature between 32 122 F 0 40 C Relative humidity that does not exceed 90 non condensing In a dry clean well ventilated and temperature controlled room away from heat sources such as hot air vents or...

Страница 12: ...other message when the temperature returns to normal The Command Line Interface CLI also reports an alarm Use the show logging buffered command to display the system log messages and the show logging command for event log messages For details see the Syslog chapters of the SFTOS Command Reference or SFTOS Configuration Guide Fan replacement is not offered as an option in the field Power CAUTION Th...

Страница 13: ...away from direct sunlight heat and air conditioning ducts Store in a dust free environment Tools Required S Series switches are shipped fully assembled encased in foam A utility knife is useful for cutting the packing tape and a 2 Phillips screwdriver is required for attaching rack screws and is also used for making some attachments including DC cables and rear cover plates Wear an anti static gua...

Страница 14: ...14 Site Preparation w w w d e l l c o m s u p p o r t d e l l c o m ...

Страница 15: ...nsure that your tabletop is stable and can handle the weight of the S2410 see Chassis Physical Design on page 27 Position the S2410 so that there is proper side ventilation see Fans and Airflow on page 12 Position the S2410 so that there is easy access to the rear power inlets and an unobstructed path between power inlets and outlets Rack or Cabinet Installation The S2410 provides three rack mount...

Страница 16: ...Ensure that there is adequate clearance surrounding the rack to permit access and airflow see Chapter Site Preparation on page 11 If you are installing two S2410 systems side by side position the two S2410 chassis at least 5 inches 12 7 cm apart to permit proper airflow Position the S2410 chassis in the rack attach the rack ears first using only the supplied screws see Attaching the Rack Ears on p...

Страница 17: ...he rack ears first using only the supplied screws see Attaching the Rack Ears on page 15 and then follow the steps below to install the S2410 chassis into a four post 19 inch equipment rack using the attached front mounting brackets and the optional adjustable rear mounting brackets Step Task 1 Align the three screw holes of the adjustable rear mounting bracket with the three holes in the S2410 ch...

Страница 18: ...ecure the chassis to the rear posts with two screws Figure 4 4 Four post Rack mounting with Adjustable Rear mounting Brackets Step 2 3 Set the adjustable rear mounting bracket to the length one of three lengths for your bracket Secure the length with the four screws Figure 4 5 Four post Rack mounting with Adjustable Rear mounting Brackets Step 3 Step Task fn00147s2410 ...

Страница 19: ...our post rack mounting with cage nuts Step Task 1 Attach the two rear brackets to the side panels Align the three holes in the bracket with the three holes on the S2410 chassis and secure the brackets to the chassis using the screws Figure 4 6 Four post Rack mounting with Cage Nuts Step 1 2 Align and secure the adjustable bracket onto the rear bracket 3 Insert the S2410 chassis into the rear of th...

Страница 20: ...and each rack post Figure 4 8 Four post Rack mounting with Cage Nuts Step 4 5 Align the rack filler panel to the rear bracket and rack posts Secure by inserting two screws into the hole in the filler panel through to the holes in the rack post Figure 4 9 Four post Rack mounting with Cage Nuts Step 5 Step Task fn00147d_s50 fn00147e_s50 ...

Страница 21: ... A and B matched to the PSU A and PSU B status LEDs on the face of the S2410 Labeling the power cords A and B can help in a diagnostic situation Where Do I Go from Here The S2410 is unique among S Series switches in several aspects It has no stacking functionality It has a dedicated Ethernet Management port commonly called the service port in addition to the standard console port and virtual manag...

Страница 22: ...22 Installing the S2410 w w w d e l l c o m s u p p o r t d e l l c o m ...

Страница 23: ...nnect to the console port This is in contrast to the straight through cable used on other S Series models In more detail the cable connections are pin 1 to pin 8 pin 2 to pin 7 pin 3 to pin 6 pin 4 to pin 5 and the inverse for pins 5 through 8 Connect the RJ 45 DB 9 adapter that is shipped with the S2410 system to the RJ 45 cable Console port pinout Pin 1 NC unused Pin 2 DTR output Pin 3 TxD outpu...

Страница 24: ...es or optical to electrical converters Note that the qualified 15 meter cable is an active cable and requires that the end labeled Active be connected to the S2410CP in order to operate correctly S2410 CX4 ports because they are tightly packed only accept cables with a connector that has a low profile pull tab and low profile cable housing Using any cable that is not approved by Dell Force10 might...

Страница 25: ...5 inches from the centerline of the connector centerline perpendicular to the long axis of the trapezoidal nozzle Accessing XFP Ports Dell Force10 offers various types of XFP transceivers For details see http www force10networks com products specifications asp All ports in the S2410P use XFP transceivers except the dedicated Ethernet Management port and the S2410CP includes four XFP ports The XFP ...

Страница 26: ...re at the following URL http www force10networks com products mediaspecifications asp Step Task 1 Figure 5 3 XFP Position the XFP so it is in the upright position XFPs on the bottom even numbered ports are upside down odd numbered ports on top install right side up with the bail latch on top in the closed position as shown here For details on XFP installation see the instruction that accompanies t...

Страница 27: ...meter Specifications Temperature acceptable range 32 to 104 F 0 to 40 C 4 to 158 F 20 to 70 C non operating Thermal Dissipation Maximum Thermal Output S2410CP 426 8 BTU Hour S2410P 768 2 BTU Hour Maximum Acceptable Altitude No performance degradation to 10 000 feet 3 048 meters Relative Humidity Operating 10 to 90 relative humidity RH non condensing Storage 10 to 95 RH non condensing Shock Designe...

Страница 28: ...thority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Canadian Department of Communication Statement European Union EMC Directive Conformance Statement Th...

Страница 29: ...turbance may arise When such trouble occurs the user may be required to take corrective actions WARNING AC Power cords are for use with Dell Force10 equipment only Do not use Dell Force10 AC power cords with any unauthorized hardware Korea MIC certification Safety Standards and Compliance Agency Certifications CUS UL 60950 1 1st Edition CSA 60950 1 03 1st Edition EN 60950 1 1st Edition EN 60825 1 ...

Страница 30: ...and national regulations Dell Force10 encourages owners of information technology IT equipment to responsibly recycle their equipment when it is no longer needed Dell Force10 offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products Waste Electrical and Electronic Equipment WEEE Directive for Recovery Recycle and Reuse o...

Страница 31: ...0 Technical Assistance Center TAC see Contacting the Technical Assistance Center on page 34 Notice to Recyclers CAUTION Breaking the case cover seal voids the warranty so this procedure is only for end of life recycling To remove the lithium closed cell clock battery 1 Remove the 1 phillips screws that connect the switch cover to the body The cover has five screws across the top of the back and th...

Страница 32: ...ay also include a chemical symbol for the metal concerned in the battery Pb for lead Hg for mercury and Cd for cadmium Users of batteries and accumulators must not dispose of batteries and accumulators as unsorted municipal waste but use the collection framework available to customers for the return recycling and treatment of batteries and accumulators Customer participation is important to minimi...

Страница 33: ...iSupport Services The URL for iSupport is http www force10networks com support The iSupport website is organized primarily into the following five tabs Home Summary of open cases RMA management and field notices as shown below Service Request Case management Software Center Software downloads bug fixes and bug tracking tool Documents User documentation FAQs field notices technical tips and white p...

Страница 34: ...Numbers on page 34 Software version number Symptom description Screen shots illustrating the symptom including any error messages These can include Output from the show tech support non paged command This report is very long so the storage buffer in your terminal program should be set high Output from the show logging This report is also included as a section in the output of show tech support Con...

Страница 35: ...tance Center on page 34 Provide the following information when using E mail or phone Part number description and serial number of the component Your name organization name telephone number fax number and e mail address Shipping address for the replacement component including a contact name phone number and e mail address A description of the failure including log messages This generally includes O...

Страница 36: ...36 Technical Support w w w d e l l c o m s u p p o r t d e l l c o m ...

Страница 37: ...mphasis 24 D Danger 5 DB 9 to RJ 45 8 depth of chassis 27 disposal switch 30 E earth ground 12 electromagnetic noise 11 electrostatic discharge 12 15 Environmental Parameters 27 ESD 12 15 25 Ethernet Management Port 8 9 24 Ethernet Management port 24 European WEEE Directive 31 F fan replacement 12 fan status 12 fans 8 12 fans and ventilation 12 flow control 23 G ground connector 7 grounding 12 H h...

Страница 38: ...face 9 Safety Standards 29 screws for rack installation 8 serial baudrate command 24 serial number switch 34 Serial Numbers Locating 34 serviceable parts 5 28 SFTOS Web User Interface 9 23 shock and vibration 27 show commands 9 show hardware command 35 show logging buffered command 12 show logging command 12 34 35 show switch command 34 show tech command 35 show tech support command 35 show versio...

Страница 39: ...user serviceable parts 28 Using CX4 Ports 24 Using XFP Ports 25 V ventilation 12 voltage 28 W Warning 5 Web UI 23 Web User Interface SFTOS 9 WEEE 30 32 width of chassis 27 X XFP Installation 25 XFP Ports Using 25 ...

Страница 40: ...40 Index w w w d e l l c o m s u p p o r t d e l l c o m ...

Страница 41: ......

Страница 42: ...w w w d ell com support dell com Printed in the U S A ...

Отзывы: