SS794_Dell_Force10_Switch_25V_50V_092311

Specifications:

 

S-Series Power-over-Ethernet Switches

Ordering Information

Order Number 

Description

S25-01-GE-24V

 

24-port 10/100/1000Base-T chassis

 

with 4 SFP ports, 2 modular slots, 

 

1AC+ 1 DC power supply, FTOS software

 
S50-01-GE-48T-V-2 

 48-port 10/100/1000Base-T chassis with 

PoE, 4 SFP ports, 2 modular slots, 1AC+ 1 

DC power supply, FTOS software

 
S50-01-10GE-2P  

2-port 10 GbE XFP module 

S50-01-10GE-2C  

2-port 10 GbE CX4 module 

S50-01-12G-2S  

2-port 12 Gbps stacking module

S50-01-24G-1S  

1-port 24 Gbps stacking module

S50-01-SSC-12G  

60 cm stacking cable for S50-01-12G-2S

S50-01-LSC-12G  

4 m stacking cable for S50-01-12G-2S 

S50-01-SSC-24G  

60 cm stacking cable for S50-01-24G-1S 

S50-01-LSC-24G  

4 m stacking cable for S50-01-24G-1S

S50-01-PSU-V 

S25V/S50V redundant power supply unit

SW-SB-LATEST  

Layer 3 FTOS software upgrade

Physical

S25N: 24 line-rate 10/100/1000Base-T ports
S50N: 48 line-rate 10/100/1000Base-T ports
4 SFP ports (shared)
1 RJ45 console/management port with RS232 signaling

Optional modules:
  2 line-rate ports 10 Gigabit Ethernet XFP 
  2 line-rate ports 10 Gigabit Ethernet CX4
  2 line-rate ports 12 Gigabit Stacking
  1 line-rate port 24 Gigabit Stacking

Size: 1 RU, 1.7 h x 17.32 w x 16.73” d (4.3 h x 44 w x 42.5 cm d)
Weight: 15.62 lbs (7.10 kg)
ISO 7779 A-weighted sound pressure level: 
  S25V: 42.9 dBA at 73.4°F (23°C), S50V: 62.2 dBA at 73.4°F (23°C)
Power supply: 100–240 VAC 50/60 Hz, –48 VDC
Max. thermal output: S25V: 349 BTU/h, S50V: 497 BTU/h
Max. current draw per System:
  6.5 A at 100/120 VAC, 3.25 A at 200/240 VAC, 11.5 A at -48 VDC
Max. current draw per system: 
  2 A at 100/120 VAC, 1 A at 200/240 VAC, 3.6 A at -48 VDC
Max. power consumption: 
  S25V: 102 W, S50V: 146 W
Max. PoE power:
  320 W using either AC or DC inputs
  790 W using load sharing AC and DC inputs
Max. operating specifications:
  Operating temperature: 32°to 122°F (0°to 50°C)
  Operating humidity: 10 to 85% (RH), non-condensing
Max. non-operating specifications: 
  Storage temperature: –40°to 158°F (–40°to 70°C)
  Storage temperature: –40°to 158°F (–40°to 70°C)
Reliability: S25V: MTBF 107,720 hours, S50V: MTBF 130,482 hours

Redundancy

Ring stacking topology with dynamic master election
Dual modular slots with up to four 10 GbE ports
Link aggregation across stack members
Power redundancy

Performance

MAC addresses: 

S25N: 16K, 50V: 32K

IPv4 routes:  

4K

IPv6 routes: 

2,500

Switching fabric capacity: 

S25V: 144 Gbps, S50V: 288 Gbps

User traffic capacity: 

S25V: 128 Gbps (95 Mpps)

 

S50V: 176 Gbps (131 Mpps)

Link aggregation: 

8 links per group, 128 groups per stack 

Stacking capacity: 

96 Gbps per stack member

Queues per port: 

4 queues

VLANs: 

1024 VLANs with 4096 tag value support

Line-rate Layer 2 switching: 

all protocols, including IPv4 and IPv6

Line-rate Layer 3 routing: 

IPv4 and IPv6

LAG load balancing:  

based on Layer 2, IPv4 or IPv6 headers

Switching latency:  

<5 µs for 64 byte frames

IEEE Compliance

802.1AB LLDP
802.1ag 

Connectivity Fault Management

802.1D 

Bridging, STP

802.1p 

L2 Prioritization

802.1Q 

VLAN Tagging, Double VLAN Tagging, GVRP

802.1s MSTP
802.1w RSTP
802.1X 

Network Access Control

802.3ab 

Gigabit Ethernet (1000BASE-T)

802.3ac 

Frame Extensions for VLAN Tagging

802.3ad 

Link Aggregation with LACP

802.3ae 

10 Gigabit Ethernet (10GBASE-X)

802.3ak 

10 Gigabit Ethernet (10GBASE-CX4)

802.3i 

Ethernet (10BASE-T)

802.3u 

Fast Ethernet (100BASE-TX)

802.3x 

Flow Control

802.3z 

Gigabit Ethernet (1000BASE-X)

ANSI/TIA-1057      LLDP-MED
Force10 

FRRP (Force10 Redundant Ring Protocol)

Force10 PVST+
MTU 

9,252 bytes

RFC and I-D Compliance

General Internet Protocols

768  

UDP  

1321  

MD5 

793  

TCP  

1350  

TFTP 

854  

Telnet  

2474  

Differentiated Services 

959  

FTP  

3164  

Syslog 

General IPv4 Protocols

791  

IPv4  

1812  

Routers 

792  

ICMP  

1858 

IP Fragment Filtering

826 

ARP  

2131  

DHCP (relay)

1027  

Proxy ARP  

2338  

VRRP 

1035 

DNS (client) 

3021  

31-bit Prefixes

1042  

Ethernet Transmission 

3046  

DHCP Option 82

1191  

Path MTU Discovery 

3069  

Private VLAN

1305  

NTPv3 

3128  

Tiny Fragment Attack 

1519  

CIDR 

  

Protection

1542  

BOOTP (relay) 

  

General IPv6 Protocols

1981  

Path MTU Discovery 

2463  

ICMPv6 

 

(partial) 

1858 

IP Fragment Filtering

2460 

IPv6 

2675  

Jumbograms

2461 

Neighbor Discovery   

3587  

Global Unicast  

 

(partial) 

  

Address Format

2462   Stateless Address 

4291  

Addressing

 Autoconfiguration 
 (partial) 

RIP

1058  

RIPv1 

2453  

RIPv2

OSPF

2154  

MD5 

3623 

Graceful Restart

1587  

NSSA 

4222 

Prioritization and 

2328   OSPFv2 

 

Congestion Avoidance

2370  

Opaque LSA 

 

BGP

1997  

Communities 

2918 

Route Refresh

2385   MD5 

3065 

Confederations

2439   Route Flap Damping 

4360 

Extended Communities

2796   Route Reflection 

4893 

4-byte ASN

2842   Capabilities 

5396 

4-byte ASN

2858   Multiprotocol Extensions   

Representation

draft-ietf-idr-bgp4-20  

BGPv4

draft-ietf-idr-restart-06 

Graceful Restart

Multicast

1112  

IGMPv1

2236   IGMPv2
3376  

IGMPv3

3569 

SSM for IPv4

4541 

IGMPv1/v2 Snooping

draft-ietf-pim-sm-v2-new-05   

PIM-SM

Network Management

1155  

SMIv1

1156  

Internet MIB

1157  

SNMPv1

1212  

Concise MIB Definitions

1215  

SNMP Traps

1493  

Bridges MIB

1850  

OSPFv2 MIB

1901  

Community-based SNMPv2

2011  

IP MIB

2012  

TCP MIB

2013  

UDP MIB

2096  

IP Forwarding Table MIB

2570  

SNMPv3

2571  

Management Frameworks

2572  

Message Processing and Dispatching

2574  

SNMPv3 USM

2575  

SNMPv3 VACM

2576  

Coexistence Between SNMPv1/v2/v3

2578  

SMIv2

2579  

Textual Conventions for SMIv2

2580  

Conformance Statements for SMIv2

2618  

RADIUS Authentication MIB

2665  

Ethernet-like Interfaces MIB

2674  

Extended Bridge MIB

2787  

VRRP MIB

2819  

RMON MIB (groups 1, 2, 3, 9)

2863  

Interfaces MIB

2865  

RADIUS

3273  

RMON High Capacity MIB

3416  

SNMPv2

3418  

SNMP MIB

3434  

RMON High Capacity Alarm MIB

3580  

802.1X with RADIUS

5060  

PIM MIB

ANSI/TIA-1057 

LLDP-MED MIB

draft-grant-tacacs-02 
draft-ietf-idr-bgp4-mib-06  BGP MIBv1
IEEE 802.1AB 

LLDP MIB

IEEE 802.1AB 

LLDP DOT1 MIB

IEEE 802.1AB 

LLDP DOT3 MIB

ruzin-mstp-mib-02 

MSTP MIB (traps)

sFlow.org sFlowv5
sFlow.org 

sFlowv5 MIB (version 1.3)

FORCE10-BGP4-V2-MIB 

 Force10 BGP MIB 

 

(draft-ietf-idr-bgp4-mibv2-05)

FORCE10-IF-EXTENSION-MIB
FORCE10-LINKAGG-MIB
FORCE10-COPY-CONFIG-MIB
FORCE10-MON-MIB
FORCE10-PRODUCTS-MIB
FORCE10-SS-CHASSIS-MIB
FORCE10-SMI
FORCE10-SYSTEM-COMPONENT-MIB
FORCE10-TC-MIB
FORCE10-TRAP-ALARM-MIB

Regulatory Compliance

Safety

UL/CSA 60950-1, 1st Edition
EN 60950-1, 1st Edition
IEC 60950-1, 1st Edition Including all National Deviations 
  and Group Differences
EN 60825-1 Safety of Laser Products Part 1: Equipment

Classification Requirements and User’s Guide

EN 60825-2 Safety of Laser Products Part 2: 
  Safety of Optical Fibre Communication Systems
FDA Regulation 21 CFR 1040.10 and 1040.11

Emissions

Australia/New Zealand: AS/NZS CISPR 22: 2006, Class A
Canada: ICES-003, Issue-4, Class A
Europe: EN 55022: 2006+A1:2007 (CISPR 22: 2006), Class A
Japan: VCCI V3/2009 Class A
USA: FCC CFR 47 Part 15, Subpart B:2009, Class A

Immunity

EN 300 386 V1.4.1:2008 EMC for Network Equipment
EN 55024: 1998 + A1: 2001 + A2: 2003
EN 61000-3-2: Harmonic Current Emissions
EN 61000-3-3: Voltage Fluctuations and Flicker
EN 61000-4-2: ESD
EN 61000-4-3: Radiated Immunity
EN 61000-4-4: EFT
EN 61000-4-5: Surge
EN 61000-4-6: Low Frequency Conducted Immunity

RoHS

All S-Series components are EU RoHS compliant

The features and specifications are for FTOS. For SFTOS features 

and specifications, please refer to the SFTOS data sheet..

© 2011 Dell Inc. All rights reserved. Force10 Networks, Adit, E-Series, Traverse, and TraverseEdge are registered trademarks and Axxius, C-Series, ExaScale, FTOS, MASTERseries, 
PowerSmart, P-Series, S-Series, TeraScale, TransAccess, VirtualScale, and VirtualView are trademarks of Dell Inc. All other company names are trademarks of their respective 
holders. Information in this document is subject to change without notice. Dell Inc. assumes no responsibility for any errors that may appear in this document.

Отзывы: