Alarms
|
51
A
Alarms
The C150 system generates alarms for the following conditions:
•
fan tray status
•
power supply status
•
RPMs status
•
high temperature on RPMs
•
line cards status
•
high temperature on line cards
A
major alarm
is any fault that would render the C150 system non-functional.
A
minor alarm
is any fault that threatens the operation of the C150 system.
You can monitor alarm conditions on the C150 system through the console and LEDs. If you configure
the SNMP command
snmp-server enable traps envmon
, FTOS also sends an SNMP trap.
In the C150 system, alarms are logged for each occurrence, but the system may not send an event log for
multiple occurrences. For example, whenever a module exceeds the shutdown threshold, the module
shuts down.
If more than one module exceeds the warning or high-temperature thresholds within a five-minute period,
the system generates one event for all affected modules, but alarms are logged for each occurrence. If the
module temperature falls to 5° lower than the warning threshold temperature, the system clears the alarm
and an SNMP trap.
Table A-1. Alarm Events and Reporting
Module
Alarm Event
Alarm LED
Reported in
event log
Status LED on
Module
Fan tray
One fan within the module fails.
minor (blinking
red)
minor N/A
More than one fan within the module fails or
hardware failure in the module.
major (red)
major
unlit
AC power
supplies
Hardware failure in a non-redundant power
configuration (two power supplies)
major (red)
major
unlit
Hardware failure in a redundant power
configuration (three or more)
minor (amber)
minor
unlit
Содержание Force10 C150
Страница 1: ...Installing and Maintaining the C150 System ...
Страница 6: ...6 Contents w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 16: ...16 Installing the C150 Chassis w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 34: ...34 Installing DC Power Entry Modules w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 38: ...38 Powering Up w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 55: ...System Specifications 55 Figure B 2 Chassis Dimensions Depth fnD0011mp 15 5 inches ...
Страница 64: ...64 Contacting Technical Support w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 65: ......
Страница 66: ...w w w d ell com support dell com Printed in the U S A ...