System diagnostics and indicator codes
This section describes the diagnostic indicators on the system front panel that displays the system status during system startup.
The following sections contain information about the chassis LEDs and indicator codes for the XC Core XC450 system.
Topics:
•
•
System health and system ID indicator codes
•
iDRAC Quick Sync 2 indicator codes
•
iDRAC Direct LED indicator codes
•
•
•
Power supply unit indicator codes
•
•
Status LED indicators
NOTE:
The indicators display solid amber if any error occurs.
Figure 98. Status LED indicators
Table 19. Status LED indicators and descriptions
Icon
Description
Condition
Corrective action
Drive indicator
The indicator turns solid amber if
there is a drive error.
●
Check the System Event Log to determine if the
drive has an error.
●
Run the appropriate Online Diagnostics test.
Restart the system and run embedded
diagnostics (ePSA).
●
If the drives are configured in a RAID array,
restart the system, and enter the host adapter
configuration utility program.
Temperature
indicator
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
Ensure that none of the following conditions exist:
●
A cooling fan has been removed or has failed.
●
System cover, air shroud, or back filler bracket
has been removed.
●
Ambient temperature is too high.
●
External airflow is obstructed.
If the problem persists, see the
section.
7
96
System diagnostics and indicator codes
Содержание EMC XC Core XC450
Страница 1: ...Dell EMC XC Core XC450 Installation and Service Manual September 2021 ...
Страница 13: ...Figure 11 Memory information Dell EMC XC Core XC450 system overview 13 ...
Страница 14: ...Figure 12 Service information electrical overview 14 Dell EMC XC Core XC450 system overview ...
Страница 15: ...Figure 13 Service information mechanical overview Dell EMC XC Core XC450 system overview 15 ...