Test objectives
Many factors must be considered when designing your solution.
The Dell EMC Surveillance Lab tests focus on storage-related factors with the
following objectives:
l
Determine the bandwidth for various Dell EMC storage arrays using FC and iSCSI.
l
Determine the bandwidth for various Dell EMC storage clusters using SMB.
l
Determine the best configuration parameters for Isilon and VNX storage options.
l
Determine best video storage performance requirements for use with Isilon scale-
out storage clusters and VNX storage arrays.
l
Determine the maximum bandwidth with multiple Video Servers.
l
Determine all factors with a lab-controlled failure, such as disabling a storage
processor, rebuilding disks, removing a node, or network path failures.
Test parameters
All test parameters and scenarios reflect standard production behavior for ISS
SecurOS under storage-intensive conditions, including typical storage functions and
failures. We followed best practices for recovery and break-fix issues for normal
situations that might arise in a standard production environment.
We used the following parameters to perform the tests:
l
Tests were conducted by loading each recorder at the maximum sustainable
bandwidth of 64 MB/s, with 7Mbps camera bandwidths were used.
l
The IP network (Layer 2) is a flat, high-availability network with plenty of capacity,
which enabled us to focus on the products we were testing.
l
All tests assumed uniform distribution of bandwidth from the ISS Video Server.
Tests conducted
We ran tests with the SmartConnect configuration in place and the SMB shares were
mounted using SmartConnect zone name:
Video playback at 20%
As video is being written to the storage, we recall or review the video at a rate
equal to 20% of the write rate.
The review did not affect the write rate, video quality, or result in dropped video.
Disk Failure test
A single disk failure is the most common failure affecting storage systems today.
When a disk fails, that disk is removed and replaced. The replacement disk is then
reconstructed.
The Isilon cluster was protected using a +2 protection scheme that allows for two
simultaneous disk failures. In our test, we failed and recovered two disks. The
SmartFail process started and the CPU utilization of the node increased with no
observed affect to the write streams.
Testing and validation
22
Dell EMC Storage with ISS SecurOS
Sizing Guide
Содержание EMC Series
Страница 1: ...Surveillance Dell EMC Storage with ISS SecurOS Sizing Guide H14192 REV 1 1 ...
Страница 4: ...CONTENTS 4 Dell EMC Storage with ISS SecurOS Sizing Guide ...
Страница 8: ...Introduction 8 Dell EMC Storage with ISS SecurOS Sizing Guide ...
Страница 12: ...Configured components 12 Dell EMC Storage with ISS SecurOS Sizing Guide ...
Страница 16: ...Solution components 16 Dell EMC Storage with ISS SecurOS Sizing Guide ...
Страница 20: ...Sizing the solution 20 Dell EMC Storage with ISS SecurOS Sizing Guide ...
Страница 25: ...CHAPTER 6 Conclusion This chapter summarizes the testing for this solution l Summary 26 Conclusion 25 ...