Dell EMC DSS 9620 Servers

Installation and Service Manual

Regulatory Model: B09B
Regulatory Type: B09B002

Содержание EMC DSS 9620

Страница 1: ...Dell EMC DSS 9620 Servers Installation and Service Manual Regulatory Model B09B Regulatory Type B09B002 ...

Страница 2: ...amage to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury or death 2018 Dell Inc or its subsidiaries All rights reserved Dell EMC and other trademarks are trademarks of Dell Inc or its subsidiaries Other trademarks may be trademarks of their respective owners 2018 11 Rev A01 ...

Страница 3: ...mperature specifications 17 Relative humidity specifications 17 Maximum vibration specifications 17 Maximum shock specifications 17 Maximum altitude specifications 18 Operating temperature de rating specifications 18 Particulate and gaseous contamination specifications 18 Standard operating temperature specifications 19 Expanded operating temperature specifications 19 Expanded operating temperatur...

Страница 4: ...ing 52 Memory mirroring 52 Sample memory configurations 53 Removing memory module 54 Installing memory module 58 Processor and heat sink 62 Removing heat sink 62 Removing processor 64 Installing processor 65 Installing heat sink 66 Expansion card and riser 71 Expansion card installation guidelines 71 Removing expansion card from slot 1 71 Installing expansion card into slot 1 72 Removing expansion...

Страница 5: ...toring the Service Tag by using the Easy Restore feature 116 Mini PERC battery 117 Removing Mini PERC battery 117 Installing Mini PERC battery 119 Supercap 121 Removing Microsemi supercap 121 Installing Microsemi supercap 123 Removing Broadcom supercap 127 Installing Broadcom supercap 129 Mezzanine card and Mini PERC 132 Removing mezzanine card 132 Installing mezzanine card 138 Removing Mini PERC ...

Страница 6: ... Removing NPDB 264 Installing NPDB 266 NVMe riser 270 Removing NVMe riser 270 Installing NVMe riser 274 Hard drive backplane 278 Removing HDD backplane 278 Installing HDD backplane 280 7 Using system diagnostics 283 Dell Embedded System Diagnostics 283 Running the Embedded System Diagnostics from Boot Manager 283 Running Embedded System Diagnostics from Lifecycle Controller 283 System diagnostic c...

Страница 7: ...half width server 3 5 inch half width server System specifications Front panel features Diagnostic indicators Locating your system service tag 2 5 inch half width server Figure 1 DSS 9620 2 5 inch half width server Table 1 DSS 9620 2 5 inch features No Item Description 1 Expansion port slot 1 Supports x8 mezzanine expansion cards connected to CPU 1 2 Server board Server board DSS 9600M with DDR4 D...

Страница 8: ...nected to CPU 2 11 Supercap Supercap and holder for PCIe RAID card Microsemi and Broadcom 12 Expansion port slot 4 Supports x16 PCIe expansion risers connected to CPU 1 13 Expansion port slot 3 Supports x8 OCP expansion cards connected to CPU 1 3 5 inch half width server Figure 2 DSS 9620 3 5 inch half width server Table 2 DSS 9620 3 5 inch features No Item Description 1 Expansion port slot 1 Supp...

Страница 9: ... Expansion port slot 5 Supports x16 PCIe risers directly connected to CPU 2 11 Supercap Supercap and holder for PCIe RAID card Microsemi and Broadcom 12 Expansion port slot 4 Supports x16 PCIe risers connected to CPU 1 13 Expansion port slot 3 Supports x8 OCP expansion cards connected to CPU 1 System specifications Figure 3 DSS 9620 dimensions Table 3 DSS 9620 dimensions Item Description Dimension...

Страница 10: ...em Service Tag 8 iDRAC Direct micro USB port The iDRAC Direct micro USB port enables you to connect a portable device to the server 9 Expansion port slot 3 Supports OCP expansion cards Connected to CPU 1 10 USB port Two USB 3 0 compliant ports Diagnostic indicators NIC indicator codes Each NIC on the back panel has an indicator that provides information about the network activity and link status T...

Страница 11: ... HDD Indicator codes The expansion adapter has LED headers that correspond to access activity and link status PERC H330 Mini Mono PERC H730P Mini Mono PERC H730 and Broadcom 9361 8i Table 6 PERC H330 Mini Mono PERC H730P Mini Mono PERC H730 and Broadcom 9361 8i LED state HDD state Green LED Amber LED 1 Empty Off Off 2 Online On Off 3 Identify Prepare for removal Blinking Off 4 Rebuild Blinking Off...

Страница 12: ... rack solution or the Getting Started Guide document that is shipped with your system For information about installing the system into a rack see the Rack documentation included with the Getting Started With Your System document that is shipped with your system For information about installing the system into the enclosure see the Getting Started Guide document that is shipped with your system For...

Страница 13: ...ator For information about installing using and troubleshooting Dell OpenManage Essentials see the Dell OpenManage Essentials User s Guide Dell com openmanagemanuals OpenManage Essentials For information about installing and using Dell SupportAssist see the Dell EMC SupportAssist Enterprise User s Guide Dell com serviceabilitytools For information about partner programs enterprise systems manageme...

Страница 14: ...hassis type to accommodate either PowerEdge C6320 or PowerEdge C6320p sleds in the PowerEdge C6300 enclosure see the Fan Control Board firmware update and Set Chassis Type procedure section in this document Dell com poweredgemanuals Troubleshooting your system For information about identifying and troubleshooting the PowerEdge server issues see the Server Troubleshooting Guide Dell com poweredgema...

Страница 15: ...ions The system supports a CR 2032 3 0 V lithium coin cell system battery Expansion bus specifications The system supports PCI express PCIe generation 3 expansion cards which need to be installed on the server board using expansion card risers The following is a list of supported expansion card risers Table 8 Expansion bus specification PCIe slots Description Form factor 1 Dell mezzanine slot x8 2...

Страница 16: ...orts the following USB 3 0 compliant ports internally and on the front panel The following table provides more information about the USB specifications Table 10 USB specifications Internal Front panel Two 4 pin USB 3 0 compliant port Two 4 pin USB 3 0 compliant port Micro AB USB connector NIC ports The systems supports one embedded Network Interface Controller NIC port DisplayPort The system suppo...

Страница 17: ...Atmosphere must be non condensing at all times Operating 10 to 80 relative humidity with 29 C 84 2 Maximum vibration specifications Table 13 Maximum vibration specifications Maximum vibration Specifications Operating 0 26 Grms at 5 Hz to 350 Hz all operational orientations Storage 1 88 Grms at 10 Hz to 500 Hz for 15 min all six sides tested Maximum shock specifications Table 14 Maximum shock speci...

Страница 18: ... If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure you may need to rectify the environmental conditions Re mediation of environmental conditions is the responsibility of the customer Table 17 Particulate contamination specifications Particulate contamination Specifications Air filtration Data center air filtration as defin...

Страница 19: ...ing temperature specifications Expanded operating temperature Specifications 10 of annual operating hours 5 C to 40 C 41 F to 104 F avoiding direct sunlight on the equipment NOTE Outside the standard operating temperature 10 C to 35 C 50 F to 95 F the system can operate for a maximum of 10 of its annual operating hours in temperatures as low as 5 C 41 F and as high as 40 C 104 F For temperatures b...

Страница 20: ...ld startup below 5 C 41 F The specified operating temperature is based on a maximum altitude of 950 m 3 116 ft PCIe Cards are not supported on slots 1 2 and 3 A maximum of six hard drives are supported on half width systems with a 165 W processor Redundant power supplies are required Non Dell qualified peripheral cards and or peripheral cards greater than 25 W are not supported 20 Technical specif...

Страница 21: ...mplete the following steps to set up your system 1 Unpack the system 2 Remove the I O connector cover from the system connectors CAUTION While installing the system ensure that it is properly aligned with the slot on the enclosure to prevent damage to the system connectors 3 Install the system in the enclosure 4 Turn on the enclosure NOTE Wait for the chassis to initialize before you press the pow...

Страница 22: ...he ethernet cable to the iDRAC9 dedicated network port You can also access iDRAC through the shared LOM mode if you have opted for a system that has the shared LOM mode enabled NOTE To access iDRAC ensure that you connect the ethernet cable to the iDRAC9 dedicated network port or use iDRAC direct by using the USB cable You can also access iDRAC through the shared LOM mode if you have opted for a s...

Страница 23: ...stems Supported Operating Systems for Dell EMC PowerEdge systems Methods to download firmware and drivers You can download the firmware and drivers by using any of the following methods Table 22 Firmware and drivers Methods Location From the Dell EMC support site Dell com support home Using Dell Remote Access Controller Lifecycle Controller iDRAC with LC Dell com idracmanuals Using BMC Dell com id...

Страница 24: ...click Submit NOTE If you do not have the Service Tag select Detect Product to allow the system to automatically detect the Service Tag or click View products and navigate to your product 3 Click Drivers Downloads The drivers that are applicable to your system are displayed 4 Download the drivers to a USB drive CD or DVD 24 Initial system setup and configuration ...

Страница 25: ...s BMC settings and device settings of your system NOTE Help text for the selected field is displayed in the graphical browser by default To view the help text in the text browser press F1 You can access system setup by using two methods Standard graphical browser The browser is enabled by default Text browser The browser is enabled by using Console Redirection Viewing System Setup About this task ...

Страница 26: ... screen to edit specific functions such as boot order system password setup password set the RAID mode and enable or disable USB ports Viewing System BIOS About this task To view the System BIOS screen perform the following steps Steps 1 Turn on or restart your system 2 Press F2 immediately after you see the following message F2 System Setup NOTE If your operating system begins to load before you ...

Страница 27: ...ed Extensible Firmware Interface UEFI is a new interface between operating systems and platform firmware The interface consists of data tables with platform related information also boot and runtime service calls that are available to the operating system and its loader The following benefits are available when the Boot Mode is set to UEFI Support for hard drive partitions are larger than 2 TB Enh...

Страница 28: ...nce on the Boot Option Setting menu When this option is set to Disabled only the first hard drive in the list is attempted to boot When this option is set to Enabled all hard drives are attempted to boot in the order selected in the Hard Disk Drive Sequence This option is not enabled for UEFI Boot Mode Boot Option Settings Configures the boot sequence and the boot devices BIOS Boot Settings Enable...

Страница 29: ...BIOS UEFI Boot Settings Boot Sequence 3 Use the arrow keys to select a boot device and use the plus and minus sign keys to move the device down or up in the order 4 Click Exit and then click Yes to save the settings on exit Network Settings You can use the Network Settings screen to modify PXE device settings The network settings option is available only in the UEFI mode NOTE The BIOS does not con...

Страница 30: ...your system 2 Press F2 immediately after you see the following message F2 System Setup NOTE If your operating system begins to load before you press F2 wait for the system to finish booting and then restart your system and try again 3 On the System Setup Main Menu screen click System BIOS 4 On the System BIOS screen click Network Settings 5 On the Network Settings screen click UEFI iSCSI Settings ...

Страница 31: ...s the setup password This option is read only if the password jumper is not installed in the system Password Status Locks the system password This option is set to Unlocked by default TPM Security NOTE The TPM menu is available only when the TPM module is installed Enables you to control the reporting mode of the TPM The TPM Security option is set to Off by default You can only modify the TPM Stat...

Страница 32: ...uses the Secure Boot Policy Objects PK KEK db dbx User Mode In User Mode PK must be installed and BIOS performs signature verification on programmatic attempts to update policy objects The BIOS allows unauthenticated programmatic transitions between modes Audit Mode In Audit Mode PK is not present The BIOS does not authenticate programmatic updates to the policy objects and transitions between mod...

Страница 33: ... system displays a message and prompts you to reenter your password You have three attempts to type the correct password After the third unsuccessful attempt the system displays an error message that the system has stopped functioning and must be turned off Even after you turn off and restart the system the error message is displayed until the correct password is entered Deleting or changing syste...

Страница 34: ...able or change an existing system password NOTE You can use the password status option with the setup password option to protect the system password from unauthorized changes System Information You can use the System Information screen to view system properties such as Service Tag system model name and the BIOS version Viewing System Information About this task To view the System Information scree...

Страница 35: ... on or restart your system 2 Press F2 immediately after you see the following message F2 System Setup NOTE If your operating system begins to load before you press F2 wait for the system to finish booting and then restart your system and try again 3 On the System Setup Main Menu screen click System BIOS 4 On the System BIOS screen click Memory Settings Memory Settings details The Memory Settings s...

Страница 36: ...ate of the memory operating mode Node Interleaving Specifies if Non Uniform Memory Architecture NUMA is supported If this field is set to Enabled memory interleaving is supported if a symmetric memory configuration is installed If the field is set to Disabled the system supports NUMA asymmetric memory configurations This option is set to Disabled by default Snoop Mode Specifies the Snoop Mode opti...

Страница 37: ...disables the Sub NUMA Cluster This option is set to Enabled by default Logical Processor Idling Enables you to improve the energy efficiency of a system It uses the operating system core parking algorithm and parks some of the logical processors in the system which in turn allows the corresponding processor cores to transition into a lower power idle state This option can only be enabled if the op...

Страница 38: ...ystem Setup NOTE If your operating system begins to load before you press F2 wait for the system to finish booting and then restart your system and try again 3 On the System Setup Main Menu screen click System BIOS 4 On the System BIOS screen click SATA Settings SATA Settings details The SATA Settings screen details are explained as follows Table 31 SATA Settings Option Description Embedded SATA E...

Страница 39: ...s undefined for removable media devices such as optical drives Port D Sets the drive type of the selected device For the Embedded SATA settings in ATA mode set this field to Auto to enable BIOS support Set it to OFF to turn off BIOS support For AHCI mode BIOS support is always enabled Model Specifies the drive model of the selected device Drive Type Specifies the type of drive attached to the SATA...

Страница 40: ...t For AHCI mode BIOS support is always enabled Model Specifies the drive model of the selected device Drive Type Specifies the type of drive attached to the SATA port Capacity Specifies the total capacity of the hard drive This field is undefined for removable media devices such as optical drives Port J Sets the drive type of the selected device For the Embedded SATA settings in ATA mode set this ...

Страница 41: ...es or disables the I OAT option Enable only if the hardware and software support the feature Embedded Video Controller Enables or disables the Embedded Video Controller option This option is set to Enabled by default Current State of Embedded Video Controller Displays the current state of the embedded video controller The Current State of Embedded Video Controller option is a read only field If th...

Страница 42: ...6 X16 or X8 or X4 or X8X4X4 or X4X4X8 Serial Communication You can use the Serial Communication screen to view the properties of the serial communication port Viewing Serial Communication About this task To view the Serial Communication screen perform the following steps Steps 1 Turn on or restart your system 2 Press F2 immediately after you see the following message F2 System Setup NOTE If your o...

Страница 43: ...s for console redirection and the serial device NOTE Every time the system boots the BIOS syncs the serial MUX setting saved in iDRAC The serial MUX setting can independently be changed in iDRAC Loading the BIOS default settings from within the BIOS setup utility may not always revert this setting to the default setting of Serial Device 1 Enables you to associate the External Serial Connector to S...

Страница 44: ...States Memory Frequency Sets the speed of the system memory You can select Maximum Performance Maximum Reliability or a specific speed Turbo Boost Enables or disables the processor to operate in the turbo boost mode This option is set to Enabled by default Energy Efficient Turbo Enables or disables the Energy Efficient Turbo option Energy Efficient Turbo EET is a mode of operation where a processo...

Страница 45: ...nly if the C States option in the Custom mode is set to disabled NOTE When C States is set to Enabled in the Custom mode changing the Monitor Mwait setting does not impact the system power or performance CPU Interconnect Bus Link Power Management Enables or disables the CPU Interconnect Bus Link Power Management This option is set to Enabled by default PCI ASPM L1 Link Power Management Enables or ...

Страница 46: ...ot NOTE The default setting for In System Characterization is subject to change in future BIOS releases When enabled In System Characterization ISC executes during POST upon detecting relevant changes in system configuration to optimize system power and performance ISC takes about 20 seconds to execute and system reset is needed for ISC results to be applied The Enabled No Reboot option executes I...

Страница 47: ...eed and Custom Minimum Fan Speed 4 Click Back Finish Yes Device Settings Device Settings enables you to configure device parameters Dell Lifecycle Controller Dell Lifecycle Controller LC provides advanced embedded systems management capabilities including system deployment configuration update maintenance and diagnosis LC is delivered as part of the iDRAC out of band solution and Dell system embed...

Страница 48: ...he boot order If the boot attempt fails the system continues with the next item in the boot order until the boot is successful or no more boot options are found One shot Boot Menu Enables you to access boot menu where you can select a one time boot device to boot from Launch System Setup Enables you to access System Setup Launch Lifecycle Controller Exits the Boot Manager and invokes the Dell Life...

Страница 49: ...ronment PXE option to boot and configure the networked systems remotely NOTE To access the PXE boot option boot the system and then press F12 The system scans and displays the active networked systems Pre operating system management applications 49 ...

Страница 50: ...in component damage NOTE Dell recommends that you always use a static mat and static strap while working on components inside the system NOTE To ensure proper operation and cooling all bays in the system and system fans must be populated always with a component or with a blank Before working inside your system Prerequisite Follow the safety guidelines listed in Safety instructions Steps 1 Turn off...

Страница 51: ...h reduced memory The system supports Flexible Memory Configuration enabling the system to be configured and run in any valid chipset architectural configuration The following are the recommended guidelines for installing memory modules All DIMMs must be DDR4 RDIMMs and LRDIMMs must not be mixed x4 and x8 DRAM based memory modules can be mixed Both dual rank and single rank RDIMMs can be populated ...

Страница 52: ...odules that use x4 device width It does not impose any specific slot population requirements Memory sparing NOTE To use memory sparing this feature must be enabled in System Setup In this mode one rank per channel is reserved as a spare If persistent correctable errors are detected on a rank the data from this rank is copied to the spare rank and the failed rank is disabled With memory sparing ena...

Страница 53: ... CPU2 CH0 D1 CPU2 CH0 D0 CPU2 CH1 D0 CPU2 CH2 D0 B6 B5 B4 B8 B7 B1 B2 B3 CPU2 CH5 CH4 CH3 CH1 CH2 CH0 CH5 CH4 CH3 CH1 CH2 CH0 Figure 6 Memory slot locations Table 37 Memory configuration specifications Processor Number of DIMMS Maximum system capacity Reliability availability and serviceability RAS features Dual processor 16 16 Single processor 8 8 Sample memory configurations The following tables...

Страница 54: ...line or telephone service and support team Damage due to servicing that is not authorized by Dell is not covered by your warranty Read and follow the safety instructions that are shipped with your product 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system WARNING The memory modules are hot to touch for some time after the system has ...

Страница 55: ...Figure 7 Removing the air baffle Installing and removing server components 55 ...

Страница 56: ...mory module by the card edges ensuring not to touch the middle of the memory module or metallic contacts 4 Press down on the two memory module locking latches The memory module partially ejects 5 Lift the memory module 56 Installing and removing server components ...

Страница 57: ...Figure 8 Removing the memory module Installing and removing server components 57 ...

Страница 58: ...ry module blanks must be installed in any memory socket that is not occupied Remove memory module blanks only if you intend to install memory modules in those sockets CAUTION To avoid damage handle memory modules by the edges at all times Steps 1 Align the indentation on the memory module with the protrusion on the DIMM slot Make sure they are aligned to avoid damaging the socket or the module 2 P...

Страница 59: ...Figure 9 Installing the memory module Installing and removing server components 59 ...

Страница 60: ...olding the air baffle 4 Align the air baffle with the DIMM sockets the end tabs runs between the DIMM locking latches 5 Press the air baffle tabs down to lock on the standoffs on the chassis 60 Installing and removing server components ...

Страница 61: ...Figure 11 Installing the air baffle Installing and removing server components 61 ...

Страница 62: ...ove the heat sink from a processor unless you intend to remove the processor The heat sink is necessary to maintain proper thermal conditions WARNING The heat sink is hot to touch Allow the heat sink to cool for some time after powering down the system 1 Ensure that you read the Safety instructions 2 Keep the 2 Phillips screwdriver handy 3 Follow the procedure listed in the Before working inside y...

Страница 63: ...Figure 12 Removing the air shroud Installing and removing server components 63 ...

Страница 64: ...e processor 1 Ensure that you read the Safety instructions 2 Before upgrading your system download the latest system BIOS version from www dell com support and follow the instructions included in the compressed download file to install the update on your system NOTE You can update the system BIOS using the Lifecycle Controller For more information about Dell Lifecycle controller see www dell com i...

Страница 65: ...essor and carrier Next steps 1 Install the new processor 2 Complete the procedure listed in After working inside your system Installing processor Prerequisites 1 Ensure that you read the Safety instructions 2 Before upgrading your system download the latest system BIOS version from www dell com support and follow the instructions included in the compressed download file to install the update on yo...

Страница 66: ...processor carrier to make sure the processor carrier is locked on the processor Figure 17 Installing the processor carrier Next steps 1 Install the heat sink 2 Complete the procedure listed in After working inside your system Installing heat sink Prerequisites 1 Ensure that you read the Safety instructions 2 Keep the 2 Phillips screwdriver handy 3 Before upgrading your system download the latest s...

Страница 67: ...OS using the Dell Lifecycle Controller 4 Complete the procedure listed in Before working inside your system 5 Install the processor Steps 1 Remove the TIM protective film from the heat sink Installing and removing server components 67 ...

Страница 68: ...Figure 18 Removing the TIM protective film 2 Align the marked corner on the heat sink with the correlating location on the processor carrier 68 Installing and removing server components ...

Страница 69: ... carrier remove the heat sink and processor assembly from the processor tray Figure 20 Removing the processor assembly from the processor tray 5 Align the processor assembly on the server board until it is seated firmly in place 6 In the marked order tighten the retaining screws to secure the processor assembly Installing and removing server components 69 ...

Страница 70: ...he air shroud is locked in place Figure 22 Installing the air shroud Next steps 1 Complete the procedure listed in After working inside your system 2 While booting press F2 to start the System Setup and ensure that the processor information matches the new system configuration 3 Run the system diagnostics to verify that the new processor operates correctly 70 Installing and removing server compone...

Страница 71: ...Ie RAID PCIe NIC PCIe Riser Processor 1 x16 x16 5 x16 PCIe SATA M 2 Card NVMe Card 3M Cable Riser Processor 2 x16 x16 6 NPIO PCIe RAID NPIO Cable Rear Riser Processor 2 x16 x16 NOTE To use an expansion card on slots 5 and 6 processor 2 must be installed NOTE Expansion card are not hot swappable Removing expansion card from slot 1 CAUTION Many repairs may only be done by a certified service technic...

Страница 72: ... installed in the appropriate riser slot Remove the riser blank only if you are installing a riser Installing expansion card into slot 3 CAUTION Many repairs may only be done by a certified service technician You should only perform troubleshooting and simple repairs as authorized in your product documentation or as directed by the online or telephone service and support team Damage due to servici...

Страница 73: ...propriate riser slot Remove the riser blank only if you are installing a riser Installing expansion card into slot 5 CAUTION Many repairs may only be done by a certified service technician You should only perform troubleshooting and simple repairs as authorized in your product documentation or as directed by the online or telephone service and support team Damage due to servicing that is not autho...

Страница 74: ... by the manufacturer See your safety information for additional details CAUTION Many repairs may only be done by a certified service technician You should only perform troubleshooting and simple repairs as authorized in your product documentation or as directed by the online or telephone service and support team Damage due to servicing that is not authorized by Dell is not covered by your warranty...

Страница 75: ...Figure 23 Removing the system battery Installing and removing server components 75 ...

Страница 76: ...echnician You should only perform troubleshooting and simple repairs as authorized in your product documentation or as directed by the online or telephone service and support team Damage due to servicing that is not authorized by Dell is not covered by your warranty Read and follow the safety instructions that came with the product NOTE Battery is a Field Replaceable Unit FRU Only Dell certified s...

Страница 77: ...Figure 24 Installing the system battery Installing and removing server components 77 ...

Страница 78: ...the correct time and date in the System Setup Time and Date fields 5 Exit the System Setup Hot swappable HDD cages Installing hot swappable HDD cage Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Remove the securing screws from the dummy bracket 2 Remove the dummy bracket 78 Installing and removing server co...

Страница 79: ...Figure 25 Removing the dummy bracket Installing and removing server components 79 ...

Страница 80: ...n the keyholes on the hot swappable HDD cage with the standoffs on the chassis 4 Slide the HDD cage to lock in place 5 Secure the HDD cage with the provided screws 80 Installing and removing server components ...

Страница 81: ...Figure 26 Installing the hot swappable HDD cage Installing and removing server components 81 ...

Страница 82: ...uisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system 3 Remove the 2 5 inch hot swappable HDDs 4 Remove the HDD backplane Steps 1 Remove the securing screws from the HDD cage 2 Pull up the plunger and slide the HDD cage to release from the chassis 3 Remove the HDD cage from the chassis 82 Installing and removing server component...

Страница 83: ...Figure 27 Removing the hot swappable HDD cage Installing and removing server components 83 ...

Страница 84: ...configured correctly to support hot swappable hard drive removal and insertion CAUTION Do not turn off or restart your system while the hard drive is being formatted Doing so can cause a hard drive failure Use only hard drives that have been tested and approved for use with the hard drive backplane When you format a hard drive allow enough time for the formatting to be complete Be aware that high ...

Страница 85: ...Figure 28 Removing the 2 5 inch HDD assembly 3 Remove the screws securing the HDD to the carrier 4 Remove the HDD from the carrier Installing and removing server components 85 ...

Страница 86: ...Figure 29 Removing the 2 5 inch HDD 86 Installing and removing server components ...

Страница 87: ...the safety guidelines listed in the Safety instructions section 2 Complete the procedure listed in Before working inside your system Steps 1 Align the HDD with the HDD carrier Make sure the connectors are facing the front Make sure the connectors are positioned as demonstrated in the following illustration 2 Secure the HDD with the provided screws Installing and removing server components 87 ...

Страница 88: ...Figure 30 Installing the 2 5 inch HDD 88 Installing and removing server components ...

Страница 89: ...ide your system Removing 3 5 inch hard drive from the rear bay Prerequisites NOTE The procedure is available only for DSS 9620 server with 3 5 inch HDD 1 Follow the safety guidelines listed in the Safety instructions section 2 Complete the procedure listed in Before working inside your system CAUTION To maintain proper system cooling all empty hard drive slots must have hard drive blanks installed...

Страница 90: ...Figure 32 Removing the 3 5 inch HDD assembly 2 Remove the screws securing the HDD to the HDD carrier 90 Installing and removing server components ...

Страница 91: ...3 Remove the HDD from the HDD carrier Installing and removing server components 91 ...

Страница 92: ...Figure 33 Removing the 3 5 inch HDD 92 Installing and removing server components ...

Страница 93: ...4 Remove the screws securing the HDD tray to the standoffs on the server base 5 Remove the HDD tray from the server Installing and removing server components 93 ...

Страница 94: ...Figure 34 Removing the HDD tray 94 Installing and removing server components ...

Страница 95: ...sites NOTE The procedure is available only for DSS 9620 server with 3 5 inch HDD 1 Follow the safety guidelines listed in the Safety instructions section 2 Complete the procedure listed in Before working inside your system Steps 1 Align the HDD tray with the standoffs on the server base 2 Secure the HDD tray with the provided screws Installing and removing server components 95 ...

Страница 96: ...Figure 35 Installing the HDD tray 96 Installing and removing server components ...

Страница 97: ...ble 44 Assembly material Description Quantity Torque lbs inch 6 32 screw 7 6 0 2 3 Align the HDD with the HDD carrier 4 Secure the HDD with the provided screws Installing and removing server components 97 ...

Страница 98: ...Figure 36 Installing the 3 5 inch HDD 98 Installing and removing server components ...

Страница 99: ...Description Quantity Torque lbs inch 6 32 screw 4 1 per HDD 6 0 2 5 Align the standoffs on the HDD assembly with the keyholes on the HDD tray 6 Slide the HDD assembly to lock in place Installing and removing server components 99 ...

Страница 100: ...Figure 37 Installing the 3 5 inch HDD assembly 100 Installing and removing server components ...

Страница 101: ...cedure listed in Before working inside your system CAUTION To prevent data loss ensure that your operating system supports hot swappable drive installation See the documentation supplied with your operating system Steps 1 Press the release button to unlock the HDD assembly 2 Pull the release latch of the HDD assembly to the fully open position 3 Pull the HDD assembly out Installing and removing se...

Страница 102: ...Figure 38 Removing the HDD assembly 102 Installing and removing server components ...

Страница 103: ...4 Remove the screws securing the HDD to the HDD tray 5 Remove the HDD module from the HDD tray Installing and removing server components 103 ...

Страница 104: ...Figure 39 Removing the HDD module 104 Installing and removing server components ...

Страница 105: ...cent drives are fully installed Inserting a hard drive carrier and attempting to lock its handle next to a partially installed carrier can damage the partially installed carrier s shield spring and make it unusable CAUTION To prevent data loss ensure that your operating system supports hot swap drive installation See the documentation supplied with your operating system CAUTION When a replacement ...

Страница 106: ...Figure 40 Installing the HDD module 106 Installing and removing server components ...

Страница 107: ...ion Quantity Torque lbs inch M3 screw 4 1 per HDD 6 0 2 3 Extend the release latch on the HDD tray to the fully open position 4 Insert the HDD assembly in the bay 5 Close the latch to secure Installing and removing server components 107 ...

Страница 108: ...Figure 41 Installing the HDD assembly 108 Installing and removing server components ...

Страница 109: ... bound to that specific server board Any attempt to remove an installed TPM plug in module breaks the cryptographic binding and it cannot be reinstalled or installed on another server board 1 Follow the safety guidelines listed in the Safety instructions section 2 Complete the procedure listed in Before working inside your system 3 Remove the PCIe card 4 Remove the mezzanine card 5 Remove the OCP ...

Страница 110: ... components and I O ports on the front CAUTION Do not lift the server board by holding a memory module slot any other connector or component 5 Pull the server board back to release the I O ports from the chassis and lift the server board out to remove 6 Place the server board in an antistatic bag Figure 43 Removing the server board 110 Installing and removing server components ...

Страница 111: ...d In the event of a server board replacement a TPM plug in module is provided along with the server board for all systems that have a TPM 3 Align the I O ports on the server board with the front of the server 4 Angle the server board into the I O ports Make sure the ports on the server board are seated correctly in the chassis 5 Gently lower the server board in the chassis 6 After the server board...

Страница 112: ...M is a dedicated microprocessor designed to secure hardware by integrating cryptographic keys into devices Software can use a Trusted Platform Module to authenticate hardware devices Because each TPM chip has a unique and secret RSA key which is embedded during the manufacture of the TPM and it is capable of performing platform authentication operation CAUTION Do not attempt to remove the Trusted ...

Страница 113: ...er server board NOTE This is a Field Replaceable Unit FRU Removal and installation procedures should be performed only by Dell certified service technicians 1 Follow the safety guidelines listed in the Safety instructions section 2 Complete the procedure listed in Before working inside your system 3 Remove the PCIe card Steps 1 Align the trust platform module into the server board connector and in...

Страница 114: ...Figure 46 Inserting the trust platform module 2 Flip down the TPM Make sure it is secured on the server board 114 Installing and removing server components ...

Страница 115: ...Figure 47 Securing the TPM Installing and removing server components 115 ...

Страница 116: ...up in a backup flash device rSPI card automatically If BIOS detects a new server board and the Service Tag in the backup flash device rSPI card BIOS prompts the user to restore the backup information Steps 1 Turn on the system If BIOS detects a new server board and if the Service Tag is present in the backup flash device rSPI card BIOS displays the Service Tag the status of the license and the UEF...

Страница 117: ...instructions section 2 Complete the procedure listed in Before working inside your system Steps 1 Disconnect the Mini PERC and PERC battery cables 2 Press the release latch to release the Mini PERC battery 3 Slide the Mini PERC battery out of the air shroud to remove Installing and removing server components 117 ...

Страница 118: ...Figure 48 Removing the Mini PERC battery 118 Installing and removing server components ...

Страница 119: ...duct documentation or as directed by the online or telephone service and support team Damage due to servicing that is not authorized by Dell is not covered by your warranty Read and follow the safety instructions that are shipped with your product 1 Follow the safety guidelines listed in the Safety instructions section 2 Complete the procedure listed in Before working inside your system Steps 1 Sl...

Страница 120: ...Figure 49 Installing the Mini PERC battery 120 Installing and removing server components ...

Страница 121: ...ap Prerequisites 1 Follow the safety guidelines listed in the Safety instructions section 2 Complete the procedure listed in Before working inside your system Steps 1 Locate the supercap battery and disconnect the cable Figure 50 Locating the supercap 2 Grasp the battery and lift it up to remove it from the holder Installing and removing server components 121 ...

Страница 122: ...Figure 51 Removing the supercap battery 122 Installing and removing server components ...

Страница 123: ...Safety instructions section Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Locate the place holder in the assigned location The screw holes on the chassis and holder align when the holder is placed correctly Figure 52 Locating the supercap 2 Insert the screws in the holder and tighten to secure the holder in place Installing and removing server com...

Страница 124: ...Figure 53 Installing the battery holder 124 Installing and removing server components ...

Страница 125: ...tion Quantity Torque lbs inch 6 32 screw 2 6 0 2 3 Position the cable to allow access for front side routing 4 Insert the battery into the holder and gently press it down until it is secured Installing and removing server components 125 ...

Страница 126: ...Figure 54 Installing the battery into the holder 126 Installing and removing server components ...

Страница 127: ...elines listed in the Safety instructions section 2 Complete the procedure listed in Before working inside your system Steps 1 Locate the supercap battery and disconnect the supercap cable Figure 55 Locating the supercap 2 Grasp the one end of the battery and lift it up to remove it from the holder Installing and removing server components 127 ...

Страница 128: ...Figure 56 Removing the supercap battery 128 Installing and removing server components ...

Страница 129: ...d in the Safety instructions section 2 Complete the procedure listed in Before working inside your system Steps 1 Locate the place holder in the assigned location The screw holes on the chassis and holder align when the holder is placed correctly Figure 57 Locating the supercap 2 Insert the screws in the holder and tighten to secure the holder in place Installing and removing server components 129...

Страница 130: ...mbly material Description Quantity Torque lbs inch M3 Screw 2 6 0 2 3 Position the cable to allow access for front side routing 4 Insert the battery into the holder and gently press it down until it is secured 130 Installing and removing server components ...

Страница 131: ...Figure 59 Installing the battery into a holder Installing and removing server components 131 ...

Страница 132: ... your system Steps 1 Remove the securing screws from the mezzanine card assembly 2 Remove the mezzanine card assembly from the chassis NOTE You must install an expansion card filler cover over an empty expansion slot to maintain Federal Communications Commission FCC certification of the system The covers also keep dust and dirt out of the system and aid in proper cooling and airflow inside the sys...

Страница 133: ...Figure 60 Removing the mezzanine card assembly Installing and removing server components 133 ...

Страница 134: ...3 Remove the bridge board from the mezzanine card assembly 134 Installing and removing server components ...

Страница 135: ...Figure 61 Removing the bridge board from the mezzanine card Installing and removing server components 135 ...

Страница 136: ...4 Remove the securing screws from the mezzanine brackets 5 Remove the support bracket and slot cover from the mezzanine card 136 Installing and removing server components ...

Страница 137: ...Figure 62 Removing the support bracket and slot cover Installing and removing server components 137 ...

Страница 138: ...e card Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Align the holes on mezzanine card with the holes on support bracket and slot cover 2 Secure the support bracket and slot cover with screws 138 Installing and removing server components ...

Страница 139: ...Figure 63 Installing the support bracket and slot cover Installing and removing server components 139 ...

Страница 140: ...50 Assembly material Description Quantity Torque lbs inch 6 32 screw 3 6 0 2 3 Align the bridge board with the mezzanine card connector 4 Install the bridge board 140 Installing and removing server components ...

Страница 141: ...Figure 64 Installing the bridge board on the mezzanine card Installing and removing server components 141 ...

Страница 142: ...osts on the chassis and the connector on the server board 6 Press the mezzanine card assembly into the server board connector until it is fully seated 7 Secure the mezzanine card assembly with provided screws 142 Installing and removing server components ...

Страница 143: ...Figure 65 Installing the mezzanine card assembly Installing and removing server components 143 ...

Страница 144: ... 1 Remove the securing screws from the Mini PERC assembly 2 Remove the Mini PERC assembly from the chassis NOTE You must install an expansion card filler cover over an empty expansion slot to maintain Federal Communications Commission FCC certification of the system The covers also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system Figure 66 Removing the M...

Страница 145: ...RC cable and the Mini PERC card 5 Remove the Mini PERC cable 6 Grasp the ends of the Mini PERC card and remove it Figure 68 Removing the Mini PERC cable and card 7 Remove the screws securing the riser board 8 Remove the bezel and riser board from the mezzanine bracket Installing and removing server components 145 ...

Страница 146: ...ini PERC Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Align the holes on riser board with the holes on mezzanine brackets 2 Secure the mezzanine brackets with screws 3 Align the bezel with the mezzanine bracket and install 146 Installing and removing server components ...

Страница 147: ...3 6 0 2 4 Align the Mini PERC on the riser board making sure the screw holes line up 5 Install the Mini PERC card on the bezel and riser board 6 Place the PERC cable over the Mini PERC connectors and install 7 Secure the Mini PERC cable and the Mini PERC with the captive screws Installing and removing server components 147 ...

Страница 148: ... Install the bridge board Figure 72 Installing the bridge board on the Mini PERC assembly 10 Turn the Mini PERC assembly over and align it with the screw posts on the chassis and the connector on the server board 11 Press the Mini PERC assembly into the server board connector until it is fully seated 12 Secure the Mini PERC assembly with the provided screws 148 Installing and removing server compo...

Страница 149: ...ons 2 Complete the procedure listed in Before working inside your system Steps 1 Remove the securing screws from the PCIe M 2 assembly 2 Remove the PCIe M 2 assembly from the chassis NOTE You must install an expansion card filler cover over an empty expansion slot to maintain Federal Communications Commission FCC certification of the system The covers also keep dust and dirt out of the system and ...

Страница 150: ...Figure 74 Removing the PCIe M 2 assembly 150 Installing and removing server components ...

Страница 151: ...3 Remove the bridge board from the PCIe M 2 assembly Installing and removing server components 151 ...

Страница 152: ...Figure 75 Removing the bridge board from the mezzanine card 152 Installing and removing server components ...

Страница 153: ...the M 2 SSD board 6 The M 2 SSD board pops up Grasp the card and slide it out Figure 76 Removing the M 2 SSD board 7 Remove the securing screws from the mezzanine brackets 8 Remove the support bracket and slot cover from the PCIe M 2 card Installing and removing server components 153 ...

Страница 154: ...Figure 77 Removing the support bracket and slot cover 154 Installing and removing server components ...

Страница 155: ... card Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Align the holes on the PCIe M 2 card with the holes on support bracket and slot cover 2 Secure the support bracket and slot cover with screws Installing and removing server components 155 ...

Страница 156: ...Figure 78 Installing the support bracket and slot cover 156 Installing and removing server components ...

Страница 157: ... the PCIe M 2 card 5 Insert the M 2 SSD until it is fully seated in the connector 6 Lower the M 2 SSD board and hold it in place 7 Secure the M 2 SSD board to the PCIe M 2 card with the captive screw Figure 79 Installing the M 2 SSD board 8 Align the bridge board in the PCIe M 2 card connector 9 Install the bridge board Installing and removing server components 157 ...

Страница 158: ...Figure 80 Installing the bridge board on the mezzanine card 158 Installing and removing server components ...

Страница 159: ...assembly Table 56 Assembly material Description Quantity Torque lbs inch 6 32 screw 3 6 0 2 Next step 1 Complete the procedure listed in After working inside your system Removing x8 SATA M 2 card Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Remove the securing screws from the SATA M 2 assembly 2 Remove the...

Страница 160: ...ommunications Commission FCC certification of the system The covers also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system Figure 82 Removing the SATA M 2 assembly 3 Remove the bridge board from the SATA M 2 assembly 160 Installing and removing server components ...

Страница 161: ...Figure 83 Removing the bridge board from the mezzanine card Installing and removing server components 161 ...

Страница 162: ... Flip over the SATA M 2 assembly 5 Loosen the screw securing the SATA M 2 card and M 2 SSD board 6 The M 2 SSD board pops up Grasp the board and slide it out 162 Installing and removing server components ...

Страница 163: ...Figure 84 Removing the M 2 SSD board Installing and removing server components 163 ...

Страница 164: ...7 Remove the securing screws from the mezzanine brackets 8 Remove the support bracket and slot cover from the SATA M 2 card 164 Installing and removing server components ...

Страница 165: ...Figure 85 Removing the support bracket and slot cover Installing and removing server components 165 ...

Страница 166: ... card Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Align the holes on the SATA M 2 card with the holes on support bracket and slot cover 2 Secure the support bracket and slot cover with screws 166 Installing and removing server components ...

Страница 167: ...Figure 86 Installing the support bracket and slot cover Installing and removing server components 167 ...

Страница 168: ... the SATA M 2 card 5 Insert the M 2 SSD until it is fully seated in the connector 6 Lower the M 2 SSD board and hold it in place 7 Secure the M 2 SSD board to the SATA M 2 card with the captive screw Figure 87 Installing the M 2 SSD board 8 Align the bridge board in the SATA M 2 card connector 9 Install the bridge board 168 Installing and removing server components ...

Страница 169: ...Figure 88 Installing the bridge board on the mezzanine card Installing and removing server components 169 ...

Страница 170: ... posts on the chassis and the connector on the server board 11 Press the SATA M 2 assembly into the server board connector until it is fully seated 12 Secure the SATA M 2 assembly with provided screws 170 Installing and removing server components ...

Страница 171: ...Figure 89 Installing the SATA M 2 assembly Installing and removing server components 171 ...

Страница 172: ...tem Removing x16 PCIe M 2 card Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Loosen the captive screw securing the PCIe M 2 card 2 Unlock the hook from the PCIe M 2 card and remove the PCIe M 2 card form the server board 172 Installing and removing server components ...

Страница 173: ...Figure 90 Removing the PCIe M 2 card Installing and removing server components 173 ...

Страница 174: ...3 Remove the screw securing the PCIe M 2 card and M 2 SSD board 4 Rotate the M 2 SSD board out and remove 174 Installing and removing server components ...

Страница 175: ...Figure 91 Removing the M 2 SSD board Installing and removing server components 175 ...

Страница 176: ...5 Remove the securing screw from the PCIe M 2 card 6 Remove the PCIe bracket from the PCIe M 2 card 176 Installing and removing server components ...

Страница 177: ...Figure 92 Removing the PCIe bracket Installing and removing server components 177 ...

Страница 178: ...Installing x16 PCIe M 2 card Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Align the PCIe bracket with the PCIe M 2 card 2 Secure the PCIe bracket with the provided screws 178 Installing and removing server components ...

Страница 179: ...Figure 93 Installing the PCIe bracket Installing and removing server components 179 ...

Страница 180: ... 1 6 0 2 3 Align the M 2 SSD board with the protrusion in the PCIe M 2 card 4 Insert the M 2 SSD until it is fully seated in the connector 5 Lower the M 2 SSD board and hold it in place 6 Insert the screws and tighten to secure 180 Installing and removing server components ...

Страница 181: ...Figure 94 Installing the M 2 SSD board Installing and removing server components 181 ...

Страница 182: ...7 Align the PCIe M 2 card with the connector on the server board 8 Press the PCIe M 2 card into the server board connector until it is fully seated Make sure the hook is locked the PCIe M 2 card 9 Tighten the captive screw on the PCIe bracket 182 Installing and removing server components ...

Страница 183: ...Figure 95 Installing the PCIe M 2 card Installing and removing server components 183 ...

Страница 184: ...tes 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Loosen the captive screw securing the SATA M 2 card 2 Unlock the hook from the SATA M 2 card and remove the SATA M 2 card form the server board 184 Installing and removing server components ...

Страница 185: ...Figure 96 Removing the SATA M 2 card Installing and removing server components 185 ...

Страница 186: ...3 Remove the screw securing the SATA M 2 card and M 2 SSD board 4 Rotate the M 2 SSD board out and remove 186 Installing and removing server components ...

Страница 187: ...Figure 97 Removing the M 2 SSD board Installing and removing server components 187 ...

Страница 188: ...5 Remove the securing screw from the SATA M 2 card 6 Remove the PCIe bracket from the SATA M 2 card 188 Installing and removing server components ...

Страница 189: ...Figure 98 Removing the PCIe bracket Installing and removing server components 189 ...

Страница 190: ...Installing x16 SATA M 2 card Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Align the PCIe bracket with the SATA M 2 card 2 Secure the PCIe bracket with the provided screws 190 Installing and removing server components ...

Страница 191: ...Figure 99 Installing the PCIe bracket Installing and removing server components 191 ...

Страница 192: ... 1 6 0 2 3 Align the M 2 SSD board with the protrusion in the SATA M 2 card 4 Insert the M 2 SSD until it is fully seated in the connector 5 Lower the M 2 SSD board and hold it in place 6 Insert the screws and tighten to secure 192 Installing and removing server components ...

Страница 193: ...Figure 100 Installing the M 2 SSD board Installing and removing server components 193 ...

Страница 194: ...7 Align the SATA M 2 card with the connector on the server board 8 Press the SATA M 2 card into the server board connector until it is fully seated Make sure the hook is locked the SATA M 2 card 9 Tighten the captive screw on the PCIe bracket 194 Installing and removing server components ...

Страница 195: ...Figure 101 Installing the SATA M 2 card Installing and removing server components 195 ...

Страница 196: ...erequisites 1 Follow the safety guidelines listed in the Safety instructions section 2 Complete the procedure listed in Before working inside your system Steps 1 Remove the securing screws from the PCIe card assembly 2 Remove the PCIe card assembly from the chassis 196 Installing and removing server components ...

Страница 197: ...Figure 102 Removing the PCIe card assembly Installing and removing server components 197 ...

Страница 198: ...ou must install an expansion card filler cover over an empty expansion slot to maintain Federal Communications Commission FCC certification of the system The covers also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system 198 Installing and removing server components ...

Страница 199: ...Figure 103 Removing the PCIe card Installing and removing server components 199 ...

Страница 200: ...5 Remove the securing screws from the riser board 6 Remove the riser board from the riser bracket 200 Installing and removing server components ...

Страница 201: ...Figure 104 Removing the riser board Installing and removing server components 201 ...

Страница 202: ...ter working inside your system 2 Complete the procedure listed in Before working inside your system Steps 1 Remove the screws securing the riser bracket 2 Remove the riser bracket from the chassis NOTE The PCIe bracket is customized for this system Retain the bracket if replacing a new PCIe card for use with the new PCIe card 3 Align the holes on riser board with the holes on riser bracket 4 Secur...

Страница 203: ...Figure 105 Installing the riser board on a bracket Installing and removing server components 203 ...

Страница 204: ...connector on the riser board 7 Secure the PCIe card with the provided screw NOTE You must install an expansion card filler cover over an empty expansion slot to maintain Federal Communications Commission FCC certification of the system The covers also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system 204 Installing and removing server components ...

Страница 205: ...Figure 106 Installing the PCIe card in a bracket Installing and removing server components 205 ...

Страница 206: ...n the PCIe card assembly with the screw posts on the chassis and the connector on the server board 9 Press the PCIe card assembly into the server board connector until it is fully seated 10 Secure the PCIe card assembly with the provided screws 206 Installing and removing server components ...

Страница 207: ...Figure 107 Installing the PCIe card assembly Installing and removing server components 207 ...

Страница 208: ... you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Remove the securing screws from the OCP card assembly 2 Remove the OCP card assembly from the chassis NOTE You must install an expansion card filler cover over an empty expansion slot to maintain Federal Communications Commission FCC certification of the system The covers also keep dust a...

Страница 209: ...Figure 108 Removing the OCP card assembly Installing and removing server components 209 ...

Страница 210: ...3 Remove the bridge board from the OCP card assembly 210 Installing and removing server components ...

Страница 211: ...Figure 109 Removing the bridge board from the OCP assembly Installing and removing server components 211 ...

Страница 212: ...rearside of the OCP card and lift it up to clear the connector on the transfer board Do not remove it completely 6 Slide the OCP card out to allow the ports on the OCP card to clear the bracket 7 Remove the OCP card 212 Installing and removing server components ...

Страница 213: ...Figure 110 Removing the OCP card Installing and removing server components 213 ...

Страница 214: ... working inside your system Installing OCP card into slot 1 Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Align the slits on the transfer board with the securing pins on the OCP bracket 2 Slide the transfer board into the pins until the securing holes on the transfer board and OCP bracket align 3 Secure the...

Страница 215: ...Figure 112 Installing the transfer board Installing and removing server components 215 ...

Страница 216: ...d over the OCP bracket and insert the ports in the slots on the bracket 5 Align the connectors on the OCP card with the slot on the transfer board and lower the OCP card in place Gently press it in place to seat it correctly 6 Secure the OCP card with screws 216 Installing and removing server components ...

Страница 217: ...Figure 113 Installing the OCP card Installing and removing server components 217 ...

Страница 218: ...67 Assembly material Description Quantity Torque lbs inch 6 32 screw 3 6 0 2 7 Align the bridge board with the transfer board connector 8 Install the bridge board 218 Installing and removing server components ...

Страница 219: ...Figure 114 Installing the bridge board on the transfer board Installing and removing server components 219 ...

Страница 220: ...he screw posts on the chassis and the connector on the server board 10 Press the OCP card assembly into the server board connector until it is fully seated 11 Secure the OCP card assembly with provided screws 220 Installing and removing server components ...

Страница 221: ...Figure 115 Installing the OCP card assembly Installing and removing server components 221 ...

Страница 222: ...rking inside your system Removing OCP card from slot 3 Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system 3 Remove the mezzanine card Steps 1 Remove the securing screws from the slot cover 2 Remove the slot cover 222 Installing and removing server components ...

Страница 223: ...Figure 116 Removing the slot cover Installing and removing server components 223 ...

Страница 224: ... and tilt upward Do not lift the back of the OCP card completely to prevent damage to the components and I O ports on the front 5 Pull the OCP card back to release the I O ports from the chassis and lift the OCP card out to remove 224 Installing and removing server components ...

Страница 225: ...1 2 Figure 117 Removing the OCP card Installing and removing server components 225 ...

Страница 226: ...ructions 2 Complete the procedure listed in Before working inside your system Steps 1 Align the I O ports on the OCP card with the front of the server 2 Angle the OCP card into the I O ports Make sure the ports on the OCP card are seated correctly in the chassis 3 Gently lower the OCP card and press the OCP card into the server board connector until it is fully seated 226 Installing and removing s...

Страница 227: ...2 1 Figure 118 Installing the OCP card Installing and removing server components 227 ...

Страница 228: ...4 Align the slot cover with the chassis 5 Secure the slot cover with the provided screws 228 Installing and removing server components ...

Страница 229: ...Figure 119 Installing the slot cover Installing and removing server components 229 ...

Страница 230: ...de your system 3M riser card Removing 3M riser card Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system 3 Remove the mezzanine card Steps 1 Remove the securing screws from the front 3M riser assembly 2 Remove the front 3M riser assembly from the chassis 230 Installing and removing server components ...

Страница 231: ...Figure 120 Removing the front 3M riser assembly Installing and removing server components 231 ...

Страница 232: ...3 Remove the securing screws from the 3M riser card 4 Remove the 3M riser card from the riser bracket 232 Installing and removing server components ...

Страница 233: ...Figure 121 Removing the front 3M riser card Installing and removing server components 233 ...

Страница 234: ...Loosen the captive screw securing the rear 3M riser card 6 Unlock the hook from the rear 3M riser card and remove the rear 3M riser card form the server board 234 Installing and removing server components ...

Страница 235: ...Figure 122 Removing the front 3M riser card Installing and removing server components 235 ...

Страница 236: ...7 Remove the securing screws from the PCIe bracket 8 Remove the rear 3M riser card from the PCIe bracket 236 Installing and removing server components ...

Страница 237: ...Figure 123 Removing the PCIe bracket Installing and removing server components 237 ...

Страница 238: ...efore working inside your system About this task Cable routing overview The following routing plan is available for the 3M riser card installation To ensure correct cable position see Figure 128 for further details Figure 124 Cable routing overview Steps 1 Remove the screws securing the riser bracket 2 Remove the riser bracket from the chassis NOTE The PCIe bracket is customized for this system Re...

Страница 239: ...Figure 125 Installing the front 3M riser card on a bracket Installing and removing server components 239 ...

Страница 240: ...t 3M riser assembly with the screw posts on the chassis and the slot 4 connector on the server board 6 Press the front 3M riser assembly into the server board connector until it is fully seated 7 Secure the front 3M riser assembly with the provided screws 240 Installing and removing server components ...

Страница 241: ...Figure 126 Installing the front 3M riser assembly Installing and removing server components 241 ...

Страница 242: ...ly material Description Quantity Torque lbs inch 6 32 screw 2 6 0 2 8 Align the PCIe bracket with the rear 3M riser card 9 Secure the PCIe bracket with the provided screws 242 Installing and removing server components ...

Страница 243: ...Figure 127 Installing the PCIe bracket Installing and removing server components 243 ...

Страница 244: ...ar 3M riser card with the slot 5 connector on the server board 11 Press the rear 3M riser card into the server board connector until it is fully seated Make sure the hook is locked the rear 3M riser card 12 Tighten the captive screw on the PCIe bracket 244 Installing and removing server components ...

Страница 245: ...Figure 128 Installing the rear 3M riser card Installing and removing server components 245 ...

Страница 246: ... your product documentation or as directed by the online or telephone service and support team Damage due to servicing that is not authorized by Dell is not covered by your warranty Read and follow the safety instructions that are shipped with your product 1 Follow the safety guidelines listed in the Safety instructions section 2 Follow the procedure listed in the Before working inside your system...

Страница 247: ...Figure 129 Removing the NPIO card assembly Installing and removing server components 247 ...

Страница 248: ...ou must install an expansion card filler cover over an empty expansion slot to maintain Federal Communications Commission FCC certification of the system The covers also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system 248 Installing and removing server components ...

Страница 249: ...Figure 130 Removing the NPIO card Installing and removing server components 249 ...

Страница 250: ...6 Remove the securing screws from the riser board 7 Remove the riser board from the riser bracket 250 Installing and removing server components ...

Страница 251: ...Figure 131 Removing the riser board Installing and removing server components 251 ...

Страница 252: ...n the After working inside your system 2 Complete the procedure listed in Before working inside your system Steps 1 Remove the screws securing the riser bracket 2 Remove the riser bracket from the chassis NOTE The PCIe bracket is customized for this system Retain the bracket if replacing a new PCIe card for use with the new PCIe card 3 Align the holes on riser board with the holes on riser bracket...

Страница 253: ...Figure 132 Installing the riser board on a bracket Installing and removing server components 253 ...

Страница 254: ... Commission FCC certification of the system The covers also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system Figure 133 Installing the NPIO card in a bracket Table 74 Assembly material Description Quantity Torque lbs inch 6 32 screw 1 6 0 2 8 Align the NPIO card assembly with the screw posts on the chassis and the connector on the server board 9 Press th...

Страница 255: ...Figure 134 Installing the NPIO card assembly Installing and removing server components 255 ...

Страница 256: ...only perform troubleshooting and simple repairs as authorized in your product documentation or as directed by the online or telephone service and support team Damage due to servicing that is not authorized by Dell is not covered by your warranty Read and follow the safety instructions that are shipped with your product 1 Follow the safety guidelines listed in the Safety instructions section 2 Foll...

Страница 257: ...Figure 136 Removing the NPIO card assembly Installing and removing server components 257 ...

Страница 258: ...ou must install an expansion card filler cover over an empty expansion slot to maintain Federal Communications Commission FCC certification of the system The covers also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system 258 Installing and removing server components ...

Страница 259: ...Figure 137 Removing the NPIO card Installing and removing server components 259 ...

Страница 260: ...6 Remove the securing screws from the riser board 7 Remove the riser board from the riser bracket 260 Installing and removing server components ...

Страница 261: ...Figure 138 Removing the riser board Installing and removing server components 261 ...

Страница 262: ...et if replacing a new PCIe card for use with the new PCIe card 3 Align the holes on riser board with the holes on riser bracket 4 Secure the riser board with screws Figure 139 Installing the riser board on a bracket Table 76 Assembly material Description Quantity Torque lbs inch 6 32 screw 2 6 0 2 5 Align the NPIO card with the riser bracket and the riser board connector 6 Insert the NPIO card in ...

Страница 263: ...d the connector on the server board 9 Press the NPIO card assembly into the server board connector until it is fully seated 10 Secure the NPIO card assembly with the provided screws Figure 141 Installing the NPIO card assembly Table 78 Assembly material Description Quantity Torque lbs inch 6 32 screw 2 6 0 2 11 Connect the cables to the NPIO card assembly Installing and removing server components ...

Страница 264: ...described in the documentation for the card NPDB Removing NPDB Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Disconnect all cables from the NPDB 2 Remove the securing screw from the NPDB 3 Lift the NPDB to remove from the chassis 264 Installing and removing server components ...

Страница 265: ...Figure 143 Removing the NPDB Installing and removing server components 265 ...

Страница 266: ...ng inside your system Installing NPDB Prerequisite Ensure that you read the Safety instructions Steps 1 Align the screw holes on the NPDB to the screw posts on the chassis 2 Lower the NPDB in place 3 Secure the NPDB with the screws 266 Installing and removing server components ...

Страница 267: ...Figure 144 Installing the NPDB Installing and removing server components 267 ...

Страница 268: ...Table 79 Assembly material Description Quantity Torque lbs inch 6 32 screw 4 6 0 2 4 Connect all cables from the server to the NPDB 268 Installing and removing server components ...

Страница 269: ...Figure 145 NPDB overview Installing and removing server components 269 ...

Страница 270: ...equisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Loosen the captive screw securing the NVMe riser 2 Unlock the hook from the NVMe riser and remove the NVMe riser form the server board 270 Installing and removing server components ...

Страница 271: ...Figure 146 Removing the NVMe riser Installing and removing server components 271 ...

Страница 272: ...3 Remove the securing screw from the NVMe riser 4 Remove the PCIe bracket from the NVMe riser 272 Installing and removing server components ...

Страница 273: ...Figure 147 Removing the PCIe bracket Installing and removing server components 273 ...

Страница 274: ...em Installing NVMe riser Prerequisites 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system Steps 1 Align the PCIe bracket with the NVMe riser 2 Secure the PCIe bracket with the provided screws 274 Installing and removing server components ...

Страница 275: ...Figure 148 Installing the PCIe bracket Installing and removing server components 275 ...

Страница 276: ...2 3 Align the NVMe riser with the connector on the server board 4 Press the NVMe riser into the server board connector until it is fully seated Make sure the hook is locked the NVMe riser 5 Tighten the captive screw on the PCIe bracket 276 Installing and removing server components ...

Страница 277: ...Figure 149 Installing the NVMe riser Installing and removing server components 277 ...

Страница 278: ...swappable HDDs 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system 3 Remove the 3 5 inch or 2 5 inch hot swappable HDDs Steps 1 Disconnect the power cabling and miniSAS cable from the HDD backplane 2 Remove the securing screw from the HDD backplane 3 Lift up the HDD backplane to remove from the chassis 278 Installing and removing serv...

Страница 279: ...Figure 150 Removing the HDD backplane Installing and removing server components 279 ...

Страница 280: ...e HDDs 1 Ensure that you read the Safety instructions 2 Complete the procedure listed in Before working inside your system 3 Remove the 3 5 inch or 2 5 inch hot swappable HDDs Steps 1 Align the HDD backplane to the HDD cage in the chassis 2 Install the HDD backplane 3 Secure the HDD backplane with the provided screw 4 Connect the power cabling and miniSAS cable to the HDD backplane 280 Installing ...

Страница 281: ...Figure 151 Installing the HDD backplane Installing and removing server components 281 ...

Страница 282: ...ial Description Quantity Torque lbs inch 6 32 screw 1 6 0 2 Next steps 1 Install the 2 5 inch hot swappable HDD 2 Complete the procedure listed in After working inside your system 282 Installing and removing server components ...

Страница 283: ... test options to provide extra information about the failed device s View status messages that inform you if tests are completed successfully View error messages that inform you of problems encountered during testing Running the Embedded System Diagnostics from Boot Manager Prerequisite Run the Embedded System Diagnostics ePSA if your system does not boot Steps 1 When the system is booting press F...

Страница 284: ...formation of all detected devices Results Displays the results of all tests that are run System health Provides the current overview of the system performance Event log Displays a time stamped log of the results of all tests run on the system This is displayed if at least one event description is recorded 284 Using system diagnostics ...

Страница 285: ...ector J_OCP_A J_OCP_B 25 PMBUS connector J_PMBUS 4 SATA x8 connector SATA1 26 CPLD JTAG connector J_CPLD_JTAG 5 SATA x6 connector SATA2 27 Internal USB connector INTERNAL_USB1 6 Lewisburg 2 U_LBG 28 PCIe x16 main riser connector J_PCIE_RISER 7 DIMM slot CPU 1 29 BIOS socket U_SPI_BIOS_SKT 8 DIMM slot CPU 2 30 SPIVU debug connector J_SPIVU1 9 CPU 2 J_CPU2_A J_CPU2_B 31 iDRAC uboot SPI socket U_BMC_...

Страница 286: ... 36 Power button SW1 15 NVMe connector J_NMVE_B1 37 Shared RJ 45 connector RJ45 16 G5 control connector J_G5_CTRL 38 Mini DP connector DP_PORT 17 Interposer connector J_INTERPOSESR 39 TPM socket TPM 18 DIMM slot CPU 2 40 iDRAC management USB DEBUG_USB1 19 PCIe x16 buried riser connector J_M2_RISER 41 SFP connector 2 SFP2 20 DIMM slot CPU 1 42 SFP connector 1 SFP1 21 CPU 1 43 UID LED LED3 22 Merge ...

Страница 287: ... Troubleshooting list Table 84 Troubleshooting list Issue description Root cause Troubleshooting step KVM test failure Incompatible brand ATEN cs1758 Suggested KVM types ATEN cs1308 ATEN cs1732b 9 Troubleshooting your system 287 ...

Страница 288: ...r customized support a Enter your system Service Tag in the Enter your Service Tag field b Click Submit The support page that lists the various support categories is displayed 4 For general support a Select your product category b Select your product segment c Select your product The support page that lists the various support categories is displayed 5 For contact details of Dell Global Technical ...