Wrist grounding strap connected to the ground
●
ESD mat
●
Needle-nose pliers
You need the following tools to assemble the cables for a DC power supply unit:
●
AMP 90871-1 hand-crimping tool or equivalent
●
Tyco Electronics 58433-3 or equivalent
●
Wire-stripper pliers to remove insulation from size 10 AWG solid or stranded, insulated copper wire
NOTE:
Use alpha wire part number 3080 or equivalent (65/30 stranding).
Cable routing
Figure 25. 12x 3.5-inch SAS/SATA + 2 x 2.5-inch SAS/SATA with APERC in Riser 1 and optional BOSS S2 module
Table 15. 12 x 3.5-inch SAS/SATA + 2 x 2.5-inch SAS/SATA with APERC in Riser 1 and optional BOSS S2
module
From
To
SIG_PWR_1 (system board power connector)
BP_PWR_1 (backplane power connector)
APERC_CTRL_SRC_SA1 (adapter PERC controller
connector)
BP_DST_SA1 (backplane signal connector)
APERC_CTRL_SRC_SB1 (adapter PERC controller
connector)
BP_DST_SA1 (rear backplane signal connector) and
BP_DST_SB1 (backplane signal connector)
BOSS_PWR (BOSS S2 module power connector on system
board)
PWR_1 (BOSS S2 module power connector)
SL6_PCH_PA4 (signal connector on system board)
PCIe_1 (BOSS S2 module signal connector)
SIG_PWR_0 (system board power connector)
BP_PWR_1 (rear backplane power connector)
Installing and removing system components
33