Table 17. Integrated Devices details (continued)
Option
Description
Slot n
: Enables or disables or only the boot driver is disabled for the PCIe slot
n. This option is set to
Enabled
by default.
Slot Bifurcation
Slot Discovery Bifurcation Settings
allows
Platform Default Bifurcation
and
Manual bifurcation Control
.
The default is set to
Platform Default Bifurcation
. The slot bifurcation field
is accessible when set to
Manual bifurcation Control
and is grayed out when
set to
Platform Default Bifurcation
.
Serial Communication
To view the
Serial Communication
screen, power on the system, press F2, and click
System Setup Main Menu
>
System
BIOS
>
Serial Communication
.
Table 18. Serial Communication details
Option
Description
Serial Communication
Selects serial communication devices (Serial Device 1 and Serial Device 2) in
BIOS. BIOS console redirection can also be enabled, and the port address can
be specified. This option is set to
Auto
by default.
Serial Port Address
Enables you to set the port address for serial devices. This option is set to
Serial Device1=COM2, Serial Device 2=COM1
by default.
NOTE:
You can use only Serial Device 2 for the Serial Over LAN (SOL)
feature. To use console redirection by SOL, configure the same port
address for console redirection and the serial device.
NOTE:
Every time the system boots, the BIOS syncs the serial MUX
setting that is saved in iDRAC. The serial MUX setting can independently
be changed in iDRAC. Loading the BIOS default settings from within the
BIOS setup utility may not always revert the serial MUX setting to the
default setting of Serial Device 1.
External Serial Connector
Enables you to associate the External Serial Connector to
Serial Device 1
,
Serial Device 2
, or the
Remote Access Device
by using this option. This
option is set to
Serial Device 1
by default.
NOTE:
Only Serial Device 2 can be used for Serial Over LAN (SOL).
To use console redirection by SOL, configure the same port address for
console redirection and the serial device.
NOTE:
Every time the system boots, the BIOS syncs the serial MUX
setting saved in iDRAC. The serial MUX setting can independently be
changed in iDRAC. Loading the BIOS default settings from within the BIOS
setup utility may not always revert this setting to the default setting of
Serial Device 1.
Failsafe Baud Rate
Specifies the failsafe baud rate for console redirection. The BIOS attempts to
determine the baud rate automatically. This failsafe baud rate is used only if
the attempt fails, and the value must not be changed. This option is set to
115200
by default.
Remote Terminal Type
Sets the remote console terminal type. This option is set to
VT100/VT220
by
default.
Redirection After Boot
Enables or disables the BIOS console redirection when the operating system is
loaded. This option is set to
Enabled
by default.
Pre-operating system management applications
15