Replacing failed components
VxRail Appliances are designed to be highly resilient. All models are configured with redundant
power and cooling, and use vSAN data protection rules to eliminate single points of failure to
keep the system operational.
Disk drives, power and cooling components are hot pluggable and customer replaceable using
automated procedures initiated from VxRail Manager. Other components including memory,
processors and even full nodes may be replaced by Dell EMC field personnel while keeping the
cluster fully operational.
NOTE
:
Do not remove a faulty FRU until you have a replacement available. To receive a
replacement component, you must open a service request with Dell EMC Support.
NOTE
:
When handling a FRU during replacement. there is the potential of inadvertently
damaging the sensitive electronic when an electrostatic charge that accumulates on your body
discharges through the circuits. Do not attempt any replacement procedures unless you
understand and follow proper ESD handling procedures. If in doubt, have Dell EMC field
personnel perform the procedure.
Identifying failed components
In VxRail Manager, identify failed components on the Physical tab within the HEALTH view. You
initiate replacement actions from within VxRail Manager as well.
The figure below is an example of the Physical tab within the HEALTH view of VxRail Manager.
A failed component is identified with Critical error.
Figure 47. VxRail Health, Physical view
This example shows a drive has a status of FAILED.