Start up sequence
When the switch powers up, the fans immediately come on at high speed. The fan speed slows as the switch continues to boot up.
After switch placement
After you have securely installed and powered on the S5200F-ON Series switch:
•
If you are using Dell EMC software, see switch documentation at
•
If you are using third-party software, see ONIE documentation at
Switch replacement
The following steps describe removing and replacing a switch with an identical replacement switch. For further assistance when replacing a
switch, contact your Dell EMC support representative.
NOTE:
Some steps do not apply if you are replacing a different switch or non-Dell EMC switch.
NOTE:
ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground strap
when handling the switch and accessories. After you remove the original packaging, place the switch and components on an
anti-static surface.
1
Back up the switch configuration to your back-up computer or laptop TFTP server.
copy running-config tftp://hostip/filepath
2
Disconnect the power source.
3
Label and remove all cables.
4
Remove the switch from the rack.
At the same time, press in the two side-release bars on the switch and slide the switch forward.
If you are using the fan trays or PSUs in the replacement switch, remove them from the switch.
5
Unpack the new switch.
For more information, see
6
Install the new switch in your rack or cabinet.
For detailed installation instructions, see
S5200F-ON Series switch installation
If you are using the fan trays or PSUs from the removed switch, reinsert them in the replacement switch.
7
Power on the switch.
For more information, see
.
8
Establish a connection to the switch CLI.
9
Confirm that the software version of the replacement switch is the same as the previously installed switch.
show os-version
If the software versions do not match, upgrade the replacement switch software using the procedure included with the firmware
download.
10 Copy the backed-up switch configuration to the new switch.
copy tftp://hostip/filepath running-config
11 Connect all the cables.