Specification
Measurement/description
Maximum operating temperature is de-rated by 5ºC above 2,133 meters (7,000 feet)
5U84 enclosures: -100 to 3,000 meters (-330 to 10,000 feet)
Maximum operating temperature is de-rated by 1ºC above 900 meters (3,000 feet)
Altitude, non-operating
-100 to 12,192 meters (-330 to 40,000 feet)
Shock, operating
5.0 g, 10 ms, ½ sine pulses, Y-axis
Shock, non-operating
2U enclosures: 30.0 g, 10 ms, ½ sine pulses
5U84 enclosures: 30.0 g, 10 ms, ½ sine pulses (Z-axis); 20.0 g, 10 ms, ½ sine pulses
(X- and Y-axes)
Vibration, operating
0.21 Grms 5 Hz to 500 Hz random
Vibration, non-operating
1.04 Grms 2 Hz to 200 Hz random
Vibration, relocation
0.3 Grms 2 Hz to 200 Hz 0.4 decades per minute
Acoustics
Operating sound power
2U enclosures:< LWAd 6.6 Bels (re 1 pW) @ 23ºC
5U84 enclosures: < LWAd 8.0 Bels (re 1 pW) @ 23ºC
Orientation and mounting:
19" rack mount (2 EIA units; 5 EIA units)
Rack rails
To fit 800 mm depth racks compliant with the SSI server rack specification
Rack characteristics
Back pressure not exceeding 5Pa (~0.5 mm H20)
Power cooling module
Specifications for the PCM are provided in the following table.
Table 35. 2U Power cooling module specifications
Specification
Measurement/description
Dimensions (size)
84.3 mm high x 104.5 mm wide x 340.8 mm long:
• X-axis length: 104.5 mm (4.11 in)
• Y-axis length: 84.3 mm (3.32 in)
• Z-axis length: 340.8 mm (37.03)
Maximum output power
580 W
Voltage range
100–200 VAC rated
Frequency
50–60 Hz
Voltage range selection
Auto-ranging: 90–264 VAC, 47–63 Hz
Maximum inrush current
20A
148
Technical specifications
Содержание PowerVault ME484
Страница 1: ...Dell EMC ME4 Series Owner s Manual ...
Страница 64: ...3 4 5 64 Module removal and replacement ...