Fans
The N3200-ON Series switch comes from the factory with two pluggable AC or DC PSUs and three pluggable fan modules. The airflow is
from the I/O panel to the PSU.
All fans and PSUs in a configuration must be in the same airflow direction.
Environmental factors can decrease the amount of time that is required between fan replacements. Check the environmental factors
regularly. An increase in temperature and/or particulate matter in the air might affect performance—for example, new equipment
installation.
Topics:
•
•
•
Components
N3248P-ON and N3248PXE-ON fans
1. Fans—Fan1 is near the left edge of the switch; Fan3 is near the center of the switch.
Fan LEDs
•
Solid green—Fan function is normal.
•
Flashing yellow—There is a fan fault.
•
Off—Fan is off.
Fan module installation
The fan module in the N3200-ON Series switch is field replaceable.
1. Remove the fan slot cover from the N3200-ON Series switch using a small #1 Phillips screwdriver. The fan slot cover has one screw
on the top and one screw on the bottom of the platform.
2. Take the fan module out of the shipping box.
3. Slide the module into the bay.
N3248P-ON and N3248PXE-ON fan installation