![Dell EMC PowerProtect DD9400 Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/dell-emc/powerprotect-dd9400/powerprotect-dd9400_installation-manual_2468365074.webp)
Anytime you display the
File System
section when the File System has not been created, the system displays an error message.
Continue with the procedure to create the file system.
Configure storage tier pages
The configure storage tier pages enable you to configure storage for each licensed tier on the system, Active Tier, Cache Tier,
and Cloud Tier. Each tier has a separate wizard page. The storage tier configuration pages cannot be accessed through the
wizard if the file system is already created.
Systems that use 8 TB disks for Active Tier storage require a certain number of disks installed in the disk shelves in order to
configure Active Tier and Cloud Tier storage. The disk requirements are:
NOTE:
●
Systems that are not listed in this table do not support 8 TB disks, and are not subject to this requirement.
●
8 TB drives are for Active Tier storage only. Cloud Tier storage uses 4 TB drives.
System
Minimum 8 TB disk packs required
for Active Tier (number of disks)
4 TB disk packs required for Cloud
Tier (number of disks)
DD6900
N/A
2 packs (30 disks)
DD9400
4 packs (60 disks)
4 packs (60 disks)
DD9900
8 packs (120 disks)
5 packs (75 disks)
Configure Active Tier
The Configure Active Tier section allows you to configure the Active Storage Tier devices. The Active Tier is where back up data
resides. To add storage to the Active Tier, select one or more devices and add them to the tier. You can add storage devices up
to the capacity licenses installed.
NOTE:
The DD3300 system requires 4 TB devices for the Active Tier.
Table 22. Addable Storage
Item
Description
ID (Device in DDVE)
The disk identifier, which can be any of the following.
●
The enclosure and disk number (in the form Enclosure Slot, or Enclosure Pack
for DS60 shelves)
●
A device number for a logical device such as those used by DD VTL and vDisk
●
A LUN
Disks
The disks that comprise the disk pack or LUN. This does not apply to DDVE
instances.
Model
The type of disk shelf. This does not apply to DDVE instances.
Disk Count
The number of disks in the disk pack or LUN. This does not apply to DDVE
instances.
Disk Size (Size in DDVE)
The data storage capacity of the disk.
Failed Disks
Failed disks in the disk pack or LUN. This does not apply to DDVE instances.
Type
SCSI. This only applies to DDVE instances.
a.
The DD OS convention for computing disk space defines one gibibyte as 2
30
bytes, giving a different disk capacity than the
manufacturer’s rating.
Table 23. Active Tier values
Item
Description
ID (Device in DDVE)
The disk identifier, which can be any of the following.
74
Configure System for Use
Содержание PowerProtect DD9400
Страница 1: ...Dell EMC PowerProtect DD9400 System Installation Guide September 2020 Rev 03...
Страница 57: ...Figure 65 Single node DD9400 with DS60 shelves Connect Cables and Power On 57...
Страница 58: ...Figure 66 HA DD9400 with DS60 shelves 58 Connect Cables and Power On...
Страница 63: ...Figure 72 Routing cables through the CMA brackets Connect Cables and Power On 63...