d. Re-enable the Trusted Platform Module (TPM). For more information, see
Upgrading the Trusted Platform Module (TPM)
.
7. Import your new or existing iDRAC Enterprise license.
For more information, see iDRAC User's Guide, at
Restore the service tag using Easy Restore
The Easy Restore feature allows you to restore your Service Tag, iDRAC license, UEFI configuration, and the system configuration data
after replacing the system board. All data is backed up automatically in a backup flash drive device. If BIOS detects a new system board,
and the Service Tag in the backup Flash device is different, BIOS prompts the user to restore the backup information.
About this task
Following is a list of options available:
1. Restore the Service Tag, iDRAC license, and diagnostics information, press
Y.
2. Navigate to the Lifecycle Controller based restore options, press
N.
3. Restore data from a previously created
Hardware Server Profile
, press
F10.
NOTE:
When the restore process is complete, BIOS prompts to restore the system configuration data.
4. To restore the system configuration data, press
Y
5. To use the default configuration settings, press
N
NOTE:
After the restore process is complete, system reboots.
NOTE:
If restoring the Service Tag is successful, you can check the Service Tag information in the System Information
screen and compare it with the Service Tag on the system.
Manually updating Service Tag
After replacing a system board, if Easy Restore fails, follow this process to manually enter the Service Tag, using
System Setup
.
About this task
If you know the system Service Tag, use the
System Setup
menu to enter the Service Tag.
Steps
1. Turn on the system.
2. To enter the
System Setup
, press
F2
.
3. Click
Service Tag Settings
.
4. Enter the Service Tag.
NOTE:
You can enter the Service Tag only when the Service Tag field is empty. Ensure that you enter the correct
Service Tag. After the Service Tag is entered, it cannot be updated or changed.
5. Click
OK
.
150
Installing and removing system components
Содержание PowerEdge R940xa
Страница 15: ...Figure 9 Configuration and layout Figure 10 Express service tag PowerEdge R940xa system overview 15 ...
Страница 17: ...Figure 13 Rear view configuration Figure 14 Jumper settings PowerEdge R940xa system overview 17 ...
Страница 19: ...Figure 18 Electrical overview PowerEdge R940xa system overview 19 ...
Страница 119: ...Figure 86 Installing the X8 PCIe Riser 1 Installing and removing system components 119 ...