Drive status indicator codes
Table 4 Drive indicators
1
2
3
1. Drive activity indicator
2. Drive status indicator
3. Drive
Table 5 Drive status indicator codes
Drive-Status Indicator Pattern
Condition
Flashes green twice per second
Identifying drive or preparing for removal.
Off
Drive ready for insertion or removal.
Note
The drive status indicator remains off until all
hard drives are initialized after the system is
turned on. Drives are not ready for insertion
or removal during this time.
Flashes green, amber, and turns off
Predicted drive failure
Flashes amber four times per second
Drive failed
Steady green
Drive online
Flashes green for three seconds, amber for
three seconds, and turns off after six seconds
Rebuild aborted
Locate the failed drive
After removing the bezel, locate the drive with the blinking LED.
The following table shows the disk layout. The slots are labeled on the server chassis.
Dell PowerEdge R630 Server FRUs