Corrective Action:
Import the virtual disk via HII as specified in section
.
Drive replacement
Issue:
An installed drive is not listed in the BOSS-S1 configuration utility
OpenManage reports
Physical disk offline
state
Probable Cause:
Drive is either in failure state or has corrupted firmware.
Corrective Action:
Reseat drive to ensure drive is inserted correctly. If error persists, attempt to update drive firmware using DUP. If
error is still present, replace erroneous drive.
Controller replacement
Issue:
Controller's UEFI configuration utility menu entry not appearing.
Probable Cause:
Either a firmware or a hardware fault
Corrective Action:
•
Flash the latest firmware on the BOSS adapter.
•
If the problem persists, shutdown the server and unplug the BOSS-S1 adapter.
•
Plug the BOSS-S1 adapter into the PCIe slot.
•
Boot the system and check the UEFI configuration utility menu again.
If the problem still persists, see
NOTE:
Ensure that the system is completely disconnected from all power sources before making any hardware changes.
Controller failure
Issue:
BOSS-S1 device is not presented to system.
Probable Cause:
Hardware fault on the card.
Corrective Action:
Replace the BOSS-S1 adapter with a new one.
Unable to boot to M.2 drive installed in slot 1
Issue:
When two unconfigured bootable M.2 drives are inserted into the BOSS-S1 device, only the slot 0 drive may be
booted to.
Probable Cause:
Working as designed, BIOS only allows booting from the first listed boot device (in this case, slot 0) per peripheral
controller. This only occurs in legacy BIOS boot mode.
Corrective Action:
Swap the drive in slot 1 to slot 0.
CLI reports unsupported features
Issue:
Several commands, options, or other features listed by the CLI state that they are unsupported when run.
Probable Cause:
CLI shows the same information on all Marvell products, but only implements the functions which are pertinent to
that platform or system.
26
Troubleshooting