Part Number: 9291458 REV00 12/19 7
DANGER
Installation must comply with all applicable fire and
health codes in your jurisdiction.
DANGER
Use appropriate safety equipment during installation
and servicing.
n
Warning
Remove all removable panels before lifting and
installing.
n
Warning
If a refrigerated base does not have a condensate
evaporator supplied, you must connect the condensate
line to a suitable drain. Otherwise, water will collect on
the floor, causing a potentially hazardous situation.
n
Warning
Moisture collecting from improper drainage can create a
slippery surface on the floor and a hazard to employees.
It is the owner’s responsibility to provide a container or
outlet for drainage.
n
Warning
Do not damage the refrigeration circuit when installing,
maintaining or servicing the unit.
n
Warning
This equipment must be positioned so that the plug is
accessible unless other means for disconnection from
the power supply (e.g., circuit breaker or disconnect
switch) is provided.
n
Warning
Adequate means must be provided to limit the
movement of this appliance without depending on or
transmitting stress to the electrical conduit.
n
Warning
To avoid instability the installation area must be capable
of supporting the combined weight of the equipment
and product. Additionally the equipment must be level
side to side and front to back.
n
Warning
This equipment is intended for indoor use only. Do not
install or operate this equipment in outdoor areas.
,
Caution
The units with LiquiTec technology cold pans contain a
non-toxic eutectic fluid within a sealed inner liner. This
fluid may leak if the tank is punctured so care must be
taken when uncrating and setting in place. The eutectic
fluid is non-toxic and may be flushed down a disposal
drain. Units with a Eutectic Fluid Cold Pan require the
same precautions. The fluid is NOT refillable and loss of
fluid due to a puncture would cause irreparable damage.
If the LiquiTec unit cold pans leak, immediately call the
Delfield service department directly at 1-800-733-8821
not your local service agent.
,
Caution
Do not position the air intake vent near steam or heat
exhaust of another appliance.
Note
This symbol indicates the location of the equipotential
bonding conductor connection.
Note
This symbol indicates a hot surface that can cause injury
to persons..
Section 2
Installation