F18 Series Service and Installation Manual
7
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
Specifications
Remote Refrigerated Reduced Height Rail
Model
# Of Doors
Shelf Max
Load (lbs)
Base Volume
FT3
Shelf
Area FT2
Volts/Hertz/
Phase
Amps
BTU Load
Base/Rail
Evap. BTU/°TD
Base/Rail
# of
Pans
F18RR44
(2) 19”
70
9.49
5.12
115/60/1
3.0
547/441
120/5°/19/23°
10
F18RR52
(1) 19” & (1) 27”
70/124
11.81
6.51
115/60/1
3.0
625/529
120/5°/23/23°
12
F18RR60
(2) 27”
124
14.14
7.9
115/60/1
5.0
703/617
120/6°/26/24°
16
F18RR70
(2) 32”
140
17.05
9.64
115/60/1
5.0
800/794
120/7°/32/24°
18
F18RR79
(1) 19” & (2) 27”
70/124
18.68
10.29
115/60/1
5.0
962/882
240/4°/36/25°
18
F18RR87
(3) 27”
124
21.30
11.85
115/60/1
5.0
1032/970
240/4°/39/25°
22
Self-Contained Refrigerated Reduced Height Rail
Model
# Of Doors
Shelf Max
Load (lbs)
Base Volume
FT3
Shelf
Area FT2
Volts/Hertz/
Phase
Amps
BTU Load
Base/Rail
BTU System
Cap. Base/Rail
# of
Pans
R-404A
oz.
H.P.
NEMA
Plug
F18RC52
(2) 19”
70
9.49
5.12
115/60/1
10.0
547/529
1903/1061
12
16
1/4
5-15P
F18RC60
(1) 19” & (1) 27”
70/124
11.81
6.51
115/60/1
12.0
625/617
2314/1121
14
24
1/3
5-15P
F18RC68
(2) 27”
124
14.14
7.9
115/60/1
12.0
703/794
2314/1544
16
24
1/3
5-15P
F18RC82
(2) 32”
140
17.05
9.64
115/60/1
14.0
800/882
3097/1648
20
32
1/2
5-20P
F18RC91
(1) 19” & (2) 27”
70/124
18.68
10.29
115/60/1
14.0
962/1058
3807/1839
22
32
1/2
5-20P
F18RC99
(3) 27”
124
21.30
11.85
115/60/1
14.0
1032/1147
3807/1839
24
32
1/2
5-20P
Remote Freezer Base
Model
# Of Doors
Shelf Max
Load (lbs)
Base Volume
FT3
Shelf
Area FT2
Volts/Hertz/
Phase
Amps
BTU Load
Base/Rail Evap. BTU/°TD
F18FR35
(1) 19”
70
5.58
2.56
115/60/1
10.0
943
160/6°
F18FR50
(2) 19”
70
12.21
5.12
115/60/1
10.0
1471
160/9°
F18FR58
(1) 19” & (1) 27”
70/124
15.00
6.51
115/60/1
10.0
1844
160/10°
F18FR66
(2) 27”
124
17.79
7.9
115/60/1
10.0
2020
160/11°
F18FR76
(2) 32”
140
21.28
9.64
115/60/1
10.0
2437
160/13°
Self-Contained Freezer Base
Model
# Of Doors
Shelf Max
Load (lbs)
Base Volume
FT3
Shelf
Area FT2
Volts/Hertz/
Phase
Amps
BTU Load
Base/Rail
BTU System
Cap. Base/Rail
H.P.
R-404A
oz.
NEMA
Plug
F18FC43
(1) 19”
70
5.58
2.56
115/60/1
10.0
943
1558
1/3
24
5-15P
F18FC62
(2) 19”
70
12.21
5.12
115/60/1
12.0
1471
1776
1/2
40
5-15P
F18FC70
(1) 19” & (1) 27”
70/124
15.00
6.51
115/60/1
16.0
1647
2713
3/4
56
5-20P
F18FC78
(2) 27”
124
17.79
7.9
115/60/1
16.0
1824
2713
3/4
56
5-20P
F18FC88
(2) 32”
140
21.28
9.64
115/60/1
16.0
2045
2713
3/4
56
5-20P
Self-Contained Dual Rails
Model
# Of Doors
Shelf Max
Load (lbs)
Base Volume
FT3
Shelf
Area FT2
Volts/Hertz/
Phase
Amps
BTU Load
Base/Rail
BTU System
Cap. Base/Rail
H.P.
R-404A
oz.
NEMA
Plug
F18PD48
(1) 27”
124
9.38
3.95
115/60/1
10.0
424/1058
2001/1865
1/5, 1/3
40
5-20P
F18PD72
(2) 27”
124
16.64
7.90
115/60/1
12.7
703/1588
2001/3174
1/5. 1/2
48
5-20P