5-5 Heavy Duty Diagnostic Procedures Data
Section 3-7 BATTERY CABLE TEST
W/500 AMP LOAD (FROM FIGURE 3-3)
5-3
POSITIVE CABLE
LOSS
V4
NEGATIVE CABLE
LOSS
V5
NEGATIVE CABLE
LOSS
(MAX. 0.500 V)
+
+
Section 3-27 ALTERNATOR WIRING LOSS
AMP LOAD = ALTERNATOR RATED OUTPUT (FROM FIGURE 3-8)
POSITIVE CIRCUIT
LOSS
V24
NEGATIVE CIRCUIT
LOSS
V25
ALTERNATOR
CIRCUIT LOSS
(MAX. 0.500 V)
+
+
Section 3-15. 3-16 STARTER SOLENOID CIRCUIT TEST
W/100 AMP LOAD (FROM FIGURE 3-6)
FIRST WIRE
LOSS
V9
SECOND WIRE
LOSS
V10
MAG SWITCH
LOSS
V11
TOTAL SOLENOID
CIRCUIT LOSS
(MAX. 1.00 V)
+
+
=
(AMP LOAD AND MAXIMUM VOLTAGE LOSSES SHOWN AR FOR 12V SYSTEMS.)