4
www.macdonaldindustries.co.nz
Panel-mounted Models (fig. E)
• Drill a Ø 36mm diameter hole.
• Pass the valve through the panel.
• Tighten the nut
against the panel.
• Tighten the 2 screws
using a 3mm Allen key.
• Connect the water supply and operate the valve several times to stabilise the time flow.
Recessed Model (fig. F)
• The wall mounting area should measure: 90x90mm, with an adjustable depth of 50-60mm.
• Connect the valve to the water supply.
• Mount the wall plate against the wall and position the silicone seal behind the wall plate to
provide a waterproof seal between the wall plate and the wall. Leave a drainage point to
allow any residual water to drain away.
• Fix the wall plate
in place.
• Tighten using the nut
.
• Activate the valve several times to stabilise the temperature.
THE INSTALLER MUST ENSURE:
• THE RECESSING AREA IS WATERPROOF TO PREVENT ANY INGRESS OF WATER;
• ANY WATER ACCIDENTALLY ENTERING THE RECESSING AREA (E.G. CONDENSATION,
RUN OFF, LEAKS, ETC.) IS NOT STAGNANT AND HAS A DRAINAGE POINT;
• THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE
WALL OR THE WALL PLATE AND THE MIXER/TAP AT LEAST ONCE A YEAR, AND MAKE
GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall. MacDonald Industries
cannot be held responsible for any ingress. For further information please call
technical support (see last page for conact details).