DEL Ozone · SAN LUIS OBISPO, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459  

 

111904 / 4-0308 Rev. F

Corona Discharge Ozone Generators

1, 2, & 4

INSTALLATION & OPERATION MANUAL

Содержание Eclipse-1

Страница 1: ...DEL Ozone SAN LUIS OBISPO CA 93401 USA 800 676 1335 Fax 805 541 8459 111904 4 0308 Rev F Corona Discharge Ozone Generators 1 2 4 INSTALLATION OPERATION MANUAL...

Страница 2: ...of the unit to permit connection to a minimum No 8 AWG 8 4 mm2 solid bond ing conductor between this point and any metal equipment metal enclosures of electrical equipment metal water pipes or conduit...

Страница 3: ...of direct Sunlight Locate generator out of reach of sprinklers or drainage spouts Allow sufficient access for maintenance and all tubing and electrical wires Ozone generator should be installed at lea...

Страница 4: ...the ozone supply tubing to the port marked OZONE OUT see Bottom View Figure 4 NOTE Plumbing the Ozone Line to the incorrect port will cause damage to the ozone generator 2D 4 Flowmeter Connect the flo...

Страница 5: ...ely2years if the pool system operates 24 hours day 365 days of the year 4B 3 Regularly check the flowmeter for proper flow and inspect ozone supply tubing for cracks or wear Replace ozone supply tubin...

Страница 6: ...valve replace the check valve with a new one Symptom LED Indicator has turned red a This means that the power supply of that specific ozone module is no longer drawing power and needs to be replaced...

Страница 7: ...ssitated by faulty installation improper maintenance improper operation misuse abuse negligence accident fire repair materials and or unauthorized accessories c any such products installed without reg...

Страница 8: ......